A review on the influence of the components on the performance of PVT modules

被引:41
作者
Emmanuel, Bisengimana [1 ]
Yuan, Yanping [1 ]
Maxime, Binama [2 ]
Gaudence, Nyiranzeyimana [3 ]
Zhou, Jinzhi [1 ]
机构
[1] Southwest Jiaotong Univ, Sch Mech Engn, Chengdu, Sichuan, Peoples R China
[2] Hohai Univ, Coll Water Conservancy & Hydropower Engn, Nanjing 210098, Peoples R China
[3] Jomo Kenyatta Univ, Sch Mech Engn, Nairobi, Kenya
基金
国家重点研发计划;
关键词
PVT module; Components of PVT module; Performance; PHOTOVOLTAIC-THERMAL COLLECTOR; PHASE-CHANGE MATERIAL; HEAT-PUMP SYSTEM; HYBRID PVT; SOLAR COLLECTOR; PV/T SYSTEM; ENERGY-STORAGE; OPERATIONAL PERFORMANCE; ECONOMIC-ANALYSIS; EXERGY ANALYSIS;
D O I
10.1016/j.solener.2021.08.042
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The Photovoltaic/Thermal (PVT) technology has attracted many researchers and scholars in order to increase the level of renewable energy utilization minimizing the issues caused by climate change especially the global warming which has the main roots on the greenhouse emissions produced by nonrenewable energy utilization. A PVT module is a combination of photovoltaic (PV) technology and solar thermal (ST) technology that receives and converts solar radiation into electrical and thermal energy at the same time leaving less greenhouse emissions. Even though the PVT technology seems simple in some designs and has low utilization cost, the inadequate performance and initial costs of PVT modules can slowdown their market. Based on research work outcomes and analysis, the design components of PVT modules have a strong influence on the performance. Analyzing the performance impacts of different main components of PVT module is very important not only for researchers but also for manufacturers because it points out both weaknesses and strengths for further improvements and invention of the technology to meet the market requirements. In this paper we deeply investigated the performance of PVT modules and the performance influence of each of the main components of PVT module by making a comprehensive review, finding analysis, summarizing and presenting the outcomes.
引用
收藏
页码:365 / 388
页数:24
相关论文
共 137 条
[81]   Performance analysis of a copper sheet laminated photovoltaic thermal collector using copper oxide - water nanofluid [J].
Michael, Jee Joe ;
Iniyan, S. .
SOLAR ENERGY, 2015, 119 :439-451
[82]   Performance comparison of encapsulated PCM PV/T, microchannel heat pipe PV/T and conventional PV/T systems [J].
Modjinou, Mawufemo ;
Ji, Jie ;
Yuan, Weiqi ;
Zhou, Fan ;
Holliday, Sarah ;
Waqas, Adeel ;
Zhao, Xudong .
ENERGY, 2019, 166 :1249-1266
[83]   A numerical and experimental study of micro-channel heat pipe solar photovoltaics thermal system [J].
Modjinou, Mawufemo ;
Ji, Jie ;
Li, Jing ;
Yuan, Weiqi ;
Zhou, Fan .
APPLIED ENERGY, 2017, 206 :708-722
[84]  
Modrek M, 2018, PROCEEDINGS OF THE ASME 12TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2018
[85]   A review of PV/T technologies: Effects of control parameters [J].
Moradi, Kamran ;
Ebadian, M. Ali ;
Lin, Cheng-Xian .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 64 :483-500
[86]   Numerical investigation of the effects of a copper foam filled with phase change materials in a water-cooled photovoltaic/thermal system [J].
Mousavi, Soroush ;
Kasaeian, Alibakhsh ;
Shafii, Mohammad Behshad ;
Jahangir, Mohammad Hossein .
ENERGY CONVERSION AND MANAGEMENT, 2018, 163 :187-195
[87]   Numerical investigation on the effect of different parameters in enhancing heat transfer performance of photovoltaic thermal systems [J].
Nahar, Afroza ;
Hasanuzzaman, M. ;
Rahim, N. A. ;
Parvin, S. .
RENEWABLE ENERGY, 2019, 132 :284-295
[88]   Numerical and experimental investigation on the performance of a photovoltaic thermal collector with parallel plate flow channel under different operating conditions in Malaysia [J].
Nahar, Afroza ;
Hasanuzzaman, M. ;
Rahim, N. A. .
SOLAR ENERGY, 2017, 144 :517-528
[89]   Water/MWCNT nanofluid based cooling system of PVT: Experimental and numerical research [J].
Nasrin, R. ;
Rahim, N. A. ;
Fayaz, H. ;
Hasanuzzaman, M. .
RENEWABLE ENERGY, 2018, 121 :286-300
[90]   Energy matrices analysis of hybrid PVT greenhouse dryer by considering various silicon and non-silicon PV modules [J].
Nayak, Sujata ;
Kumar, Ajit ;
Singh, A. K. ;
Tiwari, G. N. .
INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2014, 33 (02) :336-348