Temperature and nonlinearity corrections for a photodiode array spectrometer used in the field

被引:50
作者
Salim, Saber G. R. [1 ,2 ,3 ]
Fox, Nigel P. [1 ]
Theocharous, Evangelos [1 ]
Sun, Tong [2 ]
Grattan, Kenneth T. V. [2 ]
机构
[1] Natl Phys Lab, Teddington TW11 0LW, Middx, England
[2] City Univ London, London EC1V 0HB, England
[3] Natl Inst Stand NIS, Giza, Egypt
关键词
DIODE-ARRAY;
D O I
10.1364/AO.50.000866
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Temperature and nonlinearity effects are two important factors that limit the use of photodiode array spectrometers. Usually the spectrometer is calibrated at a known temperature against a reference source of a particular spectral radiance, and then it is used at different temperatures to measure sources of different spectral radiances. These factors are expected to be problematic for nontemperature-stabilized instruments used for in-the-field experiments, where the radiant power of the site changes continuously with the sun tilt. This paper describes the effect of ambient temperature on a nontemperature-stabilized linear photodiode array spectrometer over the temperature range from 5 degrees C to 40 degrees C. The nonlinearity effects on both signal amplification and different levels of radiant power have also been studied and are presented in this paper. (C) 2011 Optical Society of America
引用
收藏
页码:866 / 875
页数:10
相关论文
共 14 条
[1]  
BELLUSO M, 2006, MEM S A IT S, V9, P430
[2]   AUTOMATED ABSOLUTE AND RELATIVE SPECTRAL LINEARITY MEASUREMENTS ON PHOTOVOLTAIC DETECTORS [J].
BOIVIN, LP .
METROLOGIA, 1993, 30 (04) :355-360
[3]   Stray-light correction algorithm for spectrographs [J].
Brown, SW ;
Johnson, BC ;
Feinholz, ME ;
Yarbrough, MA ;
Flora, SJ ;
Lykke, KR ;
Clark, DK .
METROLOGIA, 2003, 40 (01) :S81-S84
[4]   Nonlinearity measurements of silicon photodetectors [J].
Kubarsepp, T ;
Haapalinna, A ;
Karha, P ;
Ikonen, E .
APPLIED OPTICS, 1998, 37 (13) :2716-2722
[5]   SPECTROPHOTOMETER LINEARITY TESTING USING DOUBLE-APERTURE METHOD [J].
MIELENZ, KD ;
ECKERLE, KL .
APPLIED OPTICS, 1972, 11 (10) :2294-&
[6]   Progress in field spectroscopy [J].
Milton, Edward J. ;
Schaepman, Michael E. ;
Anderson, Karen ;
Kneubuehler, Mathias ;
Fox, Nigel .
REMOTE SENSING OF ENVIRONMENT, 2009, 113 :S92-S109
[7]   Use of eutectic fixed points to characterize a spectrometer for earth observations [J].
Salim, Saber G. R. ;
Fox, Nigel P. ;
Woolliams, Emma R. ;
Winkler, Rainer ;
Pegrum, Heather M. ;
Sun, Tong ;
Grattan, Ken T. V. .
INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2007, 28 (06) :2041-2048
[8]  
SALIM SGR, 2010, THESIS CITY U LONDON
[9]  
SALIM SGR, 2010, APPL OPT UNPUB
[10]   The application of a chemical sensor array detector in ion chromatography for the determination of Na+, NH4+, K+, Mg2+ and Ca2+ in water samples [J].
Shen, HD ;
Cardwell, TJ ;
Cattrall, RW .
ANALYST, 1998, 123 (10) :2181-2184