Endovascular repair of abdominal aortic aneurysm: An initial experience

被引:44
作者
Nasim, A
Thompson, MM
Sayers, RD
Bolia, A
Bell, PRF
机构
[1] Department of Surgery, Clinical Sciences Building, Leicester Royal Infirmary NHS Trust
关键词
D O I
10.1002/bjs.1800830428
中图分类号
R61 [外科手术学];
学科分类号
摘要
Endovascular repair of abdominal aortic aneurysm (AAA) was attempted in ten patients over a 12-month period. Median age was 72 (range 61-82) years and median AAA diameter was 5.5 (range 5.2-6.0) cm. An aortoaortic (tube) graft was used in seven patients and a tapered aortoiliac reconstruction in three. There were two failures requiring conversion to open repair. Additional procedures included iliac artery angioplasty (two), coil embolization of an associated common iliac aneurysm (one) and femorodistal bypass (one). Median operating time was 162 (range 95-270) min and median blood loss was 1200 (range 800-2000) ml. Median hospital stay was 9 (range 5-21) days. Complications included death (one), reversible acute tubular necrosis (one) and prolonged ventilation (one). Postoperative evaluation with duplex ultrasonography and computed tomography demonstrated three perigraft leaks (two proximal and one distal). It is concluded that endovascular repair of AAA is feasible but is associated with significant complications and requires careful evaluation before widespread use.
引用
收藏
页码:516 / 519
页数:4
相关论文
共 20 条
  • [1] MORTALITY-RATES ASSOCIATED WITH OPERATIVE TREATMENT OF INFRARENAL ABDOMINAL AORTIC-ANEURYSM IN THE NETHERLANDS
    AKKERSDIJK, GJM
    VANDERGRAAF, Y
    VANBOCKEL, JH
    DEVRIES, AC
    EIKELBOOM, BC
    [J]. BRITISH JOURNAL OF SURGERY, 1994, 81 (05) : 706 - 709
  • [2] TRANS-FEMORAL PLACEMENT OF INTRALUMINAL POLYURETHANE PROSTHESIS FOR ABDOMINAL AORTIC-ANEURYSM
    BALKO, A
    PIASECKI, GJ
    SHAH, DM
    CARNEY, WI
    HOPKINS, RW
    JACKSON, BT
    [J]. JOURNAL OF SURGICAL RESEARCH, 1986, 40 (04) : 305 - 309
  • [3] CHUTER TAM, 1995, J ENDOVASC SURG, V2, P126
  • [4] TRANSLUMINALLY-PLACED COILSPRING ENDARTERIAL TUBE GRAFTS - LONG-TERM PATENCY IN CANINE POPLITEAL ARTERY
    DOTTER, CT
    [J]. INVESTIGATIVE RADIOLOGY, 1969, 4 (05) : 329 - +
  • [5] DIAGNOSIS AND MANAGEMENT OF 528 ABDOMINAL AORTIC-ANEURYSMS
    FIELDING, JWL
    BLACK, J
    ASHTON, F
    SLANEY, G
    CAMPBELL, DJ
    [J]. BRITISH MEDICAL JOURNAL, 1981, 283 (6287) : 355 - 359
  • [6] PROGNOSIS OF ABDOMINAL AORTIC-ANEURYSM
    GREENHALGH, RM
    [J]. BRITISH MEDICAL JOURNAL, 1990, 301 (6744) : 136 - 136
  • [7] RUPTURED ABDOMINAL AORTIC-ANEURYSM - 6-YEAR FOLLOW-UP RESULTS OF A MULTICENTER PROSPECTIVE-STUDY
    JOHNSTON, KW
    AMELI, FM
    AU, HH
    BAIRD, RJ
    BALACHANDRA, VK
    BARBER, GG
    BASIAN, H
    BLUNDELL, PE
    BROWN, PM
    BRUNEAU, L
    CALLAGHAN, JC
    CARROLL, SE
    CHIU, CJ
    DEROSE, G
    DOOBAY, BS
    DOUVILLE, Y
    DOWNS, AR
    DUNN, RS
    DUTTON, JW
    ERRET, LE
    EVANS, G
    FONG, HMT
    FRY, PD
    GELBAND, ET
    GOLDBACH, MM
    GOLDBERG, MR
    GOLDSTEIN, AS
    GOODING, JT
    GRANT, KC
    GUNSTENSEN, J
    HARRIS, KA
    HEIDE, AR
    HILDEBRAND, H
    HUNTING, MC
    HYATT, HJ
    JAMIESON, WG
    KALMAN, PG
    KING, WL
    LAURENDEAU, F
    LITHERLAND, HK
    MACKEAN, GL
    MADDISON, GD
    MAGGISANO, R
    MCPHAIL, NV
    MEADS, GE
    MICHALSKI, AH
    MODREY, DL
    MOFFAT, RC
    MOONJE, VB
    MORIN, JE
    [J]. JOURNAL OF VASCULAR SURGERY, 1994, 19 (05) : 888 - 900
  • [8] OPERATIVE MORTALITY-RATES FOR INTACT AND RUPTURED ABDOMINAL AORTIC-ANEURYSMS IN MICHIGAN - AN 11-YEAR STATEWIDE EXPERIENCE
    KATZ, DJ
    STANLEY, JC
    ZELENOCK, GB
    [J]. JOURNAL OF VASCULAR SURGERY, 1994, 19 (05) : 804 - 817
  • [9] INTRALUMINAL BYPASS OF ABDOMINAL AORTIC-ANEURYSM - FEASIBILITY STUDY
    LABORDE, JC
    PARODI, JC
    CLEM, MF
    TIO, FO
    BARONE, HD
    RIVERA, FJ
    ENCARNACION, CE
    PALMAZ, JC
    [J]. RADIOLOGY, 1992, 184 (01) : 185 - 190
  • [10] PERCUTANEOUS ENDOVASCULAR GRAFT - EXPERIMENTAL EVALUATION
    LAWRENCE, DD
    CHARNSANGAVEJ, C
    WRIGHT, KC
    GIANTURCO, C
    WALLACE, S
    [J]. RADIOLOGY, 1987, 163 (02) : 357 - 360