A Monte Carlo Study of the Relationship between the Time Structures of Prompt Gammas and the In-vivo Radiation Dose in Proton Therapy

被引:2
作者
Shin, Wook-Geun [1 ]
Min, Chul Hee [1 ]
Shin, Jae-Ik [2 ]
Jeong, Jong Hwi [2 ]
Lee, Se Byeong [2 ]
机构
[1] Yonsei Univ, Dept Radiat Convergence Engn, Wonju 220710, South Korea
[2] Natl Canc Ctr, Proton Therapy Ctr, Goyang 410769, South Korea
基金
新加坡国家研究基金会;
关键词
Proton therapy; Prompt gamma; Time structure; Range verification; Monte Carlo simulation; RANGE VERIFICATION; SIMULATION; CAMERA; SYSTEM;
D O I
10.3938/jkps.67.248
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
For in-vivo range verification in proton therapy, attempts have been made to measure the spatial distribution of the prompt gammas generated by the proton-induced interactions and to determine the proton dose distribution. However, the high energies of prompt gammas and background gammas are still problematic in measuring the distribution. In this study, we suggested a new method for determining the in-vivo range by utilizing the time structure of the prompt gammas formed during the rotation of a range modulation wheel (RMW) in passive scattering proton therapy. To validate the Monte Carlo code simulating the proton beam nozzle, we compared the axial percent depth doses (PDDs) with the measured PDDs for varying beam range from 4.73 to 24.01 cm. Also, we assessed the relationship between the proton dose rate and the time structure of the prompt gammas in a water phantom. The results of the PDD showed agreement within relative errors of 1.1% in the distal range and 2.9% in the modulation width. The average dose difference in the modulation was assessed as less than 1.3% by comparison with the measurements. The time structure of prompt gammas was well-matched, within 0.39 ms, with the proton dose rate, and this enabled an accurate prediction of the in-vivo range.
引用
收藏
页码:248 / 253
页数:6
相关论文
共 12 条
  • [1] GEANT4-a simulation toolkit
    Agostinelli, S
    Allison, J
    Amako, K
    Apostolakis, J
    Araujo, H
    Arce, P
    Asai, M
    Axen, D
    Banerjee, S
    Barrand, G
    Behner, F
    Bellagamba, L
    Boudreau, J
    Broglia, L
    Brunengo, A
    Burkhardt, H
    Chauvie, S
    Chuma, J
    Chytracek, R
    Cooperman, G
    Cosmo, G
    Degtyarenko, P
    Dell'Acqua, A
    Depaola, G
    Dietrich, D
    Enami, R
    Feliciello, A
    Ferguson, C
    Fesefeldt, H
    Folger, G
    Foppiano, F
    Forti, A
    Garelli, S
    Giani, S
    Giannitrapani, R
    Gibin, D
    Cadenas, JJG
    González, I
    Abril, GG
    Greeniaus, G
    Greiner, W
    Grichine, V
    Grossheim, A
    Guatelli, S
    Gumplinger, P
    Hamatsu, R
    Hashimoto, K
    Hasui, H
    Heikkinen, A
    Howard, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) : 250 - 303
  • [2] Physics settings for using the Geant4 toolkit in proton therapy
    Jarlskog, Christina Zacharatou
    Paganetti, Harald
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) : 1018 - 1025
  • [3] Monte Carlo modeling and validation of a proton treatment nozzle by using the Geant4 toolkit
    Kim, Dae-Hyun
    Kang, Young Nam
    Suh, Tae-Suk
    Shin, Jungwook
    Kim, Jong Won
    Yoo, Seung Hoon
    Park, Seyjoon
    Lee, Sang Hoon
    Cho, Sungkoo
    Shin, Dongho
    Kim, Dae Yong
    Lee, Se Byeong
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (07) : 1125 - 1130
  • [4] Clinical Application of In-Room Positron Emission Tomography for In Vivo Treatment Monitoring in Proton Radiation Therapy
    Min, Chul Hee
    Zhu, Xuping
    Winey, Brian A.
    Grogg, Kira
    Testa, Mauro
    El Fakhri, Georges
    Bortfeld, Thomas R.
    Paganetti, Harald
    Shih, Helen A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (01): : 183 - 189
  • [5] Development of array-type prompt gamma measurement system for in vivo range verification in proton therapy
    Min, Chul Hee
    Lee, Han Rim
    Kim, Chan Hyeong
    Lee, Se Byeong
    [J]. MEDICAL PHYSICS, 2012, 39 (04) : 2100 - 2107
  • [6] Prompt gamma measurements for locating the dose falloff region in the proton therapy
    Min, Chul-Hee
    Kim, Chan Hyeong
    Youn, Min-Young
    Kim, Jong-Won
    [J]. APPLIED PHYSICS LETTERS, 2006, 89 (18)
  • [7] Monte Carlo patient study on the comparison of prompt gamma and PET imaging for range verification in proton therapy
    Moteabbed, M.
    Espana, S.
    Paganetti, H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (04) : 1063 - 1082
  • [8] Optimizing a three-stage Compton camera for measuring prompt gamma rays emitted during proton radiotherapy
    Peterson, S. W.
    Robertson, D.
    Polf, J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (22) : 6841 - 6856
  • [9] Monte Carlo Modeling and Simulation of a Passive Treatment Proton Beam Delivery System using a Modulation Wheel
    Shin, Jungwook
    Kim, Dongwook
    Lim, Young Kyung
    Ahn, Sunghwan
    Shin, Dongho
    Yoon, Myong Geun
    Park, Sung-Yong
    Lee, Se Byeong
    Kwak, Jungwon
    Son, Dongchul
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2010, 56 (01) : 153 - 163
  • [10] Prompt gamma imaging with a slit camera for real-time range control in proton therapy
    Smeets, J.
    Roellinghoff, F.
    Prieels, D.
    Stichelbaut, F.
    Benilov, A.
    Busca, P.
    Fiorini, C.
    Peloso, R.
    Basilavecchia, M.
    Frizzi, T.
    Dehaes, J. C.
    Dubus, A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (11) : 3371 - 3405