Comprehensive review of 2-ethyl-1-hexanol as an indoor air pollutant

被引:42
|
作者
Wakayama, Takanari [1 ,2 ]
Ito, Yuki [1 ]
Sakai, Kiyoshi [1 ,2 ]
Miyake, Mio [1 ]
Shibata, Eiji [3 ]
Ohno, Hiroyuki [2 ]
Kamijima, Michihiro [1 ]
机构
[1] Nagoya City Univ, Dept Occupat & Environm Hlth, Grad Sch Med Sci, Nagoya, Aichi, Japan
[2] Nagoya City Publ Hlth Res Inst, Dept Environm Hlth, Nagoya, Aichi, Japan
[3] Aichi Med Univ, Dept Hlth & Psychosocial Med, Sch Med, Nagakute, Aichi, Japan
关键词
2-ethyl-1-hexanol; emission mechanism; indoor air pollution; indoor concentration; sick building syndrome; volatile organic compounds; VOLATILE ORGANIC-COMPOUNDS; SICK BUILDING SYNDROME; DI 2-ETHYLHEXYL ADIPATE; PERFUSED-RAT-LIVER; DI(2-ETHYLHEXYL) PHTHALATE; DI-(2-ETHYLHEXYL) PHTHALATE; MITOCHONDRIAL RESPIRATION; PEROXISOME PROLIFERATION; DEVELOPMENTAL TOXICITY; INHALATION EXPOSURE;
D O I
10.1002/1348-9585.12017
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objectives: 2-Ethyl-1-hexanol (2EH), a fragrance ingredient and a raw material for the production of plasticizer di(2-ethylhexyl) phthalate, is responsible for sick building syndrome (SBS). This review aims to clarify the 2EH characteristics as an indoor air pollutant such as indoor air concentration, emission mechanism, toxicity, and clinical effects. Methods: Scientific publications in English that has been made available on PubMed as of June 2018 and ad hoc publications in regional languages were reviewed. Results: Inhalation exposure to 2EH caused mucous membrane irritation in the eyes, nose, and throat in experimental animals. Studies in human volunteers revealed an increase in olfactory irritation and eye discomfort. There has been increasing evidence of 2EH being present in indoor air in buildings. The primary sources of 2EH emissions are not building materials themselves, but instead the hydrolysis of plasticizers and flooring adhesives. In particular, compounds like di(2-ethylhexyl)phthalate present in polyvinyl chloride flooring materials are hydrolyzed upon contact with alkaline moisture-containing concrete floors. That being said, it may be observed that indoor concentrations of 2EH increased every year during summer. Conclusions: Unlike other volatile organic compounds that cause SBS, 2EH can be retained in indoor air for long durations, increasing the likelihood of causing undesirable health effects in building occupants exposed to it. As a precautionary measure, it is important to use flooring materials that do not emit 2EH by hydrolysis, or to dry concrete before covering with flooring materials.
引用
收藏
页码:19 / 35
页数:17
相关论文
共 50 条
  • [1] 2-ethyl-1-hexanol in indoor air as a possible cause of sick building symptoms
    Kamijima, M
    Sakai, K
    Shibata, E
    Yamada, T
    Itohara, S
    Ohno, H
    Hayakawa, R
    Sugiura, M
    Yamaki, K
    Takeuchi, Y
    JOURNAL OF OCCUPATIONAL HEALTH, 2002, 44 (03) : 186 - 191
  • [2] Fragrance material review on 2-ethyl-1-hexanol
    McGinty, D.
    Scognamiglio, J.
    Letizia, C. S.
    Api, A. M.
    FOOD AND CHEMICAL TOXICOLOGY, 2010, 48 : S115 - S129
  • [3] Indoor air pollution by 2-ethyl-1-hexanol in non-domestic buildings in Nagoya, Japan
    Sakai, Kiyoshi
    Kamijima, Michihiro
    Shibata, Eiji
    Ohno, Hironobu
    Nakajima, Tamie
    JOURNAL OF ENVIRONMENTAL MONITORING, 2006, 8 (11): : 1122 - 1128
  • [4] Reactivity of 2-ethyl-1-hexanol in the atmosphere
    Gallego-Iniesta Garcia, Maria Paz
    Moreno Sanroma, Alberto
    Martin Porrero, Maria Pilar
    Tapia Valle, Araceli
    Cabanas Galan, Beatriz
    Salgado Munoz, Maria Sagrario
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2010, 12 (13) : 3294 - 3300
  • [5] Enzymatic resolution of the enantiomers of 2-ethyl-1-hexanol
    Harris, Lonnie
    Oldham, Davis
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 250
  • [6] Vibrational band assignment of 2-ethyl-1-hexanol
    Clasp, Trocia N.
    Reeve, Scott W.
    Koizumi, Hideya
    JOURNAL OF THEORETICAL & COMPUTATIONAL CHEMISTRY, 2017, 16 (03):
  • [7] The indoor air pollutant 2-ethyl-hexanol activates CD4 cells
    Yoshida, Yasuhiro
    Liu, Jiqin
    Sugiura, Tsutomu
    Lshidao, Toru
    Ueno, Susumu
    Yanagita, Hitomi
    Fueta, Yukiko
    Kunugita, Naoki
    Hori, Hajime
    Yamashita, Uki
    CHEMICO-BIOLOGICAL INTERACTIONS, 2009, 177 (02) : 137 - 141
  • [8] 2-ethyl-1-hexanol in indoor air as a possible cause of sick building symptoms (vol 44, pg 188, 2002)
    Kamijima, M
    Sakai, K
    Shibata, E
    Yamada, T
    Itohara, S
    Ohno, H
    Hayakawa, R
    Sugiura, M
    Yamaki, K
    Takeuchi, Y
    JOURNAL OF OCCUPATIONAL HEALTH, 2002, 44 (05) : AR2 - AR2
  • [9] Asthma symptoms in relation to measured building dampness in upper concrete floor construction, and 2-ethyl-1-hexanol in indoor air
    Norbäck, D
    Wieslander, G
    Nordström, K
    Wålinder, R
    INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2000, 4 (11) : 1016 - 1025
  • [10] DETERMINATION OF 2-ETHYL-1-HEXANOL IN WATER BY PURGE-AND-TRAP
    TOMSEJ, T
    CHEMICKE LISTY, 1995, 89 (01): : 55 - 57