Stability evaluation of water droplets levitated by a TinyLev acoustic levitator for laser induced breakdown spectroscopy

被引:17
作者
Meneses-Nava, M. A. [1 ]
Rosas-Roman, I [1 ]
Barbosa-Garcia, O. [1 ]
Rodriguez, M. [1 ]
Maldonado, J. L. [1 ]
机构
[1] Ctr Invest Opt AC, Loma Bosque 115, Guanajuato 37150, Mexico
关键词
LIBS; Acoustic levitation; Liquid; QUANTITATIVE-ANALYSIS; AQUEOUS-SOLUTION; LIQUID SAMPLES; SPECTROCHEMICAL ANALYSIS; ELEMENTAL ANALYSIS; MATRIX CONVERSION; PARTICLES; METALS; PLASMA; MICRO;
D O I
10.1016/j.sab.2020.105855
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Stability of acoustic levitated water droplets, for laser induced breakdown spectroscopy (LIBS), is required in order to obtain shot-to-shot reproducibility and low limits of detection. Although stabilization is possible by increasing the TinyLev levitator's operational voltage, at high voltages liquid droplets shatter when inserted at the nodes of the acoustic levitator. An alternative for stabilization, it is the use of a four beam laser arrangement, similar to an optical trap. In this case, we have found adequate not to use focusing lenses, since the goal is just to exert certain lateral pressure to counteract the lateral pressure instabilities generated by the acoustic levitator and simplify the optical arrangement. For an operational voltage of 8.5 V, a reduction on the droplet's horizontal deviation of 42% is attained at 650 mW laser power. At these experimental conditions, LIBS measurements were conducted on water samples doped with different metals. It is shown that, at this droplet's deviation, it is possible to analyze liquid samples despite a complete liquid evaporation is not reached. For Al samples a limit of detection (LoD) of 0.22 ppm is calculated from a calibration curve, and LoD of 1.18, 0.15, 0.94 and 0.7 ppm for Cu, Mn, Pb and Ni respectively, are estimated by signal to noise ratios values. These results show that even though, the final size of the liquid droplets is large, there is not a reduction on the lowest detectable concentration obtained, compared to other LIBS works on liquid samples. Leading up to conclude that pre-concentration effect takes more relevance than residual liquid's detrimental effect.
引用
收藏
页数:8
相关论文
共 46 条
[31]   A hydrogel-based solidification method for the direct analysis of liquid samples by laser-induced breakdown spectroscopy [J].
Lin, Qingyu ;
Bian, Fang ;
Wei, Zhimei ;
Wang, Shuai ;
Duan, Yixiang .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (07) :1412-1419
[32]   Ultra-trace metallic element detection in liquid samples using laser induced breakdown spectroscopy based on matrix conversion and crosslinked PVA polymer membrane [J].
Lin, Qingyu ;
Han, Xiaodan ;
Wang, Jie ;
Wei, Zhimei ;
Liu, Kunping ;
Duan, Yixiang .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (08) :1622-1630
[33]   TinyLev: A multi-emitter single-axis acoustic levitator [J].
Marzo, Asier ;
Barnes, Adrian ;
Drinkwater, Bruce W. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (08)
[34]   The feasibility of liquid sample microanalysis using polydimethylsiloxane microfluidic chips with in-channel and in-port laser-induced breakdown spectroscopy detection [J].
Metzinger, Aniko ;
Nagy, Andrea ;
Gaspar, Attila ;
Marton, Zsuzsanna ;
Kovacs-Szeles, Eva ;
Galbacs, Gabor .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 126 :23-30
[35]  
Musazzi S, 2014, SPRINGER SER OPT SCI, V182, P1, DOI 10.1007/978-3-642-45085-3
[36]   Dual-pulse laser-induced breakdown spectroscopy in bulk aqueous solution with an orthogonal beam geometry [J].
Pearman, W ;
Scaffidi, J ;
Angel, SM .
APPLIED OPTICS, 2003, 42 (30) :6085-6093
[37]   LIBS - An efficient approach for the determination of Cr in industrial wastewater [J].
Rai, Nilesh K. ;
Rai, A. K. .
JOURNAL OF HAZARDOUS MATERIALS, 2008, 150 (03) :835-838
[38]   Study of laser-induced breakdown emission from liquid under double-pulse excitation [J].
Rai, VN ;
Yueh, FY ;
Singh, JP .
APPLIED OPTICS, 2003, 42 (12) :2094-2101
[39]   Spectrochemical analysis of Cs in water and soil using low pressure laser induced breakdown spectroscopy [J].
Ramli, Muliadi ;
Khumaeni, Ali ;
Kurniawan, Koo Hendrik ;
Tjia, May On ;
Kagawa, Kiichiro .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 132 :8-12
[40]   Dispersive micro solid-phase extraction (DμSPE) with graphene oxide as adsorbent for sensitive elemental analysis of aqueous samples by laser induced breakdown spectroscopy (LIBS) [J].
Ruiz, F. J. ;
Ripoll, L. ;
Hidalgo, M. ;
Canals, A. .
TALANTA, 2019, 191 :162-170