Study of a Modified Flux-Coupling-Type SFCL for Efficient Fault Ride-Through in a PMSG Wind Turbine Under Different Types of Faults

被引:25
作者
Chen, Lei [1 ]
He, Huiwen [2 ]
Chen, Hongkun [1 ]
Wang, Lei [2 ]
Zhu, Lin [3 ]
Shu, Zhengyu [4 ]
Tang, Fei [1 ]
Yang, Jun [1 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Hubei, Peoples R China
[2] China Elect Power Res Inst, State Key Lab Power Grid Environm Protect, Wuhan 430074, Hubei, Peoples R China
[3] Univ Tennessee, Dept Elect Engn & Comp Sci, Knoxville, TN 37996 USA
[4] State Grid Yichang Power Supply Co, Yichang 443000, Peoples R China
来源
CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING-REVUE CANADIENNE DE GENIE ELECTRIQUE ET INFORMATIQUE | 2017年 / 40卷 / 03期
基金
中国国家自然科学基金;
关键词
Fault ride-through (FRT) capability; modified flux-coupling-type SFCL; permanent-magnet synchronous generator (PMSG); transient simulation; wind turbine; LOW-VOLTAGE-RIDE; ENERGY-CONVERSION SYSTEM; CURRENT LIMITER; POWER-SYSTEMS; DFIG; CAPABILITY; PERFORMANCE; ENHANCEMENT; CONVERTER; OPERATION;
D O I
10.1109/CJECE.2017.2690829
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Regarding the permanent-magnet synchronous generator (PMSG)-based wind turbine system, this paper proposes a modified flux-coupling-type superconducting fault current limiter (SFCL) to enhance its fault ride-through (FRT) performance. The modified SFCL's structural principle and theoretical influence on the PMSG ride through capability are conducted, and a comparison of the SFCL and a dynamic braking chopper (BC) is performed. Using MATLAB, a detailed model of a 1.5-MW PMSG-based wind turbine integrated with the SFCL/BC is built, and the simulations of symmetrical and asymmetrical faults are done. From the results, introducing the modified SFCL can limit the fault currents in the generator and grid sides. In addition, using the modified SFCL, we are able to compensate the generator voltage and alleviate the dc-link overvoltage. Thus, the wind turbine system's power balance is improved, and also the fault recovery process can be accelerated. On the whole, the modified SFCL is better than the BC for assisting the FRT operation of the PMSG.
引用
收藏
页码:189 / 200
页数:12
相关论文
共 57 条
[1]   Impact of VSC faults on dynamic performance and low voltage ride through of DFIG [J].
Abdou, A. F. ;
Abu-Siada, A. ;
Pota, H. R. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 65 :334-347
[2]   Impedance characteristics of non-inductive coil wound with two kinds of HTS wire in parallel [J].
Ahn, Min Cheol ;
Park, Dong Keun ;
Yang, Seong Eun ;
Ko, Tae Kuk .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2008, 18 (02) :640-643
[3]   Permanent Magnet Synchronous Generator-Based Standalone Wind Energy Supply System [J].
Bhende, C. N. ;
Mishra, S. ;
Malla, Siva Ganesh .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2011, 2 (04) :361-373
[4]   Application of Multiple Resistive Superconducting Fault-Current Limiters for Fast Fault Detection in Highly Interconnected Distribution Systems [J].
Blair, Steven M. ;
Booth, Campbell D. ;
Burt, Graeme M. ;
Bright, Chris G. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (02) :1120-1127
[5]   Technical Evaluation of Superconducting Fault Current Limiters Used in a Micro-Grid by Considering the Fault Characteristics of Distributed Generation, Energy Storage and Power Loads [J].
Chen, Lei ;
Tu, Xiude ;
Chen, Hongkun ;
Yang, Jun ;
Wu, Yayi ;
Shu, Xin ;
Ren, Li .
ENERGIES, 2016, 9 (10)
[6]   Application of a modified flux-coupling type superconducting fault current limiter to transient performance enhancement of micro-grid [J].
Chen, Lei ;
Zheng, Feng ;
Deng, Changhong ;
Li, Shichun ;
Li, Miao ;
Liu, Hui ;
Zhu, Lin ;
Guo, Fang .
PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2015, 518 :144-148
[7]   Fault Ride-Through Capability Improvement of DFIG-Based Wind Turbine by Employing a Voltage-Compensation-Type Active SFCL [J].
Chen, Lei ;
Zheng, Feng ;
Deng, Changhong ;
Li, Zhe ;
Guo, Fang .
CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING-REVUE CANADIENNE DE GENIE ELECTRIQUE ET INFORMATIQUE, 2015, 38 (02) :132-142
[8]   Study on the Application of a Flux-Coupling-Type Superconducting Fault Current Limiter for Decreasing HVdc Commutation Failure [J].
Chen, Lei ;
Pan, Hao ;
Deng, Changhong ;
Zheng, Feng ;
Li, Zhe ;
Guo, Fang .
CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING-REVUE CANADIENNE DE GENIE ELECTRIQUE ET INFORMATIQUE, 2015, 38 (01) :10-19
[9]   Effects of a flux-coupling type superconducting fault current limiter on the surge current caused by closed-loop operation in a 10 kV distribution network [J].
Chen, Lei ;
Li, Zhe ;
Deng, Changhong ;
Liu, Hui ;
Weng, Yixuan ;
Xu, Qiushi ;
Wu, Zhikui ;
Tang, Yuejin .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 69 :160-166
[10]   Fault Ride-Through Capability Enhancement of DFIG-Based Wind Turbine With a Flux-Coupling-Type SFCL Employed at Different Locations [J].
Chen, Lei ;
Deng, Changhong ;
Zheng, Feng ;
Li, Shichun ;
Liu, Yang ;
Liao, Yuxiang .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2015, 25 (03)