On the effect of marrow in the mechanical behavior and crush response of trabecular bone

被引:18
作者
Halgrin, J.
Chaari, F. [1 ]
Markiewicz, E.
机构
[1] Univ Lille Nord France, F-59000 Lille, France
关键词
Trabecular bone; Marrow; Mechanical parameters; Fluid flow; YIELD STRAIN; STRENGTH;
D O I
10.1016/j.jmbbm.2011.09.003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The present paper focuses on the mechanical behavior analysis of bones at mesoscopic scale, paying a special attention to the trabecular bone and the bone marrow filling the porosities. Uni-axial quasi-static compression tests under unconfined conditions have been performed to identify the mechanical behavior of 46 trabecular bone samples. The bone marrow for 22 samples has been preserved to analyze the fluid flow effects on the crushing response. Although deformation patterns do not differ significantly, the average crush behavior of the trabecular bone shows an unexpected decrease of the mechanical properties when the marrow is kept in the sample (26% for the elastic modulus (E-a), 38% for the maximum compressive stress (sigma(max)) and 33% for the average stress (sigma(mean))). An explanation is given by analyzing the contribution of the bone marrow viscosity which smooths the mechanical response. A numerical analysis on an idealized trabecula confirms that the marrow induces transverse pressure and extra local stress on trabeculae during its flow, causing the premature collapse of the trabecular network. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:231 / 237
页数:7
相关论文
共 27 条
[1]  
Behr M., 2003, Computer Methods in Biomechanics and Biomedical Engineering, V6, P263, DOI 10.1080/10255840310001606080
[2]  
Bryant J D, 1988, Eng Med, V17, P55, DOI 10.1243/EMED_JOUR_1988_017_017_02
[3]  
BRYNK T, 2010, J BIOMECHANICS
[4]   COMPRESSIVE BEHAVIOR OF BONE AS A 2-PHASE POROUS STRUCTURE [J].
CARTER, DR ;
HAYES, WC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (07) :954-962
[5]   Identification of the spongy bone mechanical behavior under compression loads:: numerical simulation versus experimental results [J].
Chaari, F. ;
Markiewicz, E. ;
Drazetic, P. .
INTERNATIONAL JOURNAL OF CRASHWORTHINESS, 2007, 12 (03) :247-253
[6]  
CHARLEBOIS M, 2008, J BIOMECHANICS, V41
[7]  
Delille R., 2007, THESIS U VALENCIENNE
[8]  
FOLLET H, 2006, J BIOMECHANICS
[9]  
Gibson L. J., 1997, CELLULAR SOLIDS STRU, V2nd ed
[10]  
HALGRIN J, 2007, MODELLING HETEROGENE