Are distal radius fracture classifications reproducible? Intra and interobserver agreement

被引:38
作者
Belloti, Joao Carlos [1 ]
Sugawara Tamaoki, Marcel Jun [1 ]
da Silveira Franciozi, Carlos Eduardo [1 ]
Gomes dos Santos, Joao Baptista [1 ]
Balbachevsky, Daniel [1 ]
Chap, Eduardo Chap
Albertoni, Walter Manna [1 ]
Faloppa, Flavio [1 ]
机构
[1] Univ Fed Sao Paulo, Escola Paulista Med, Dept Orthoped & Traumatol, Sao Paulo, Brazil
来源
SAO PAULO MEDICAL JOURNAL | 2008年 / 126卷 / 03期
关键词
Colles' fracture; radius fractures; classification; reproducibility of results; validation studies;
D O I
10.1590/S1516-31802008000300008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
CONTEXT AND OBJECTIVE: Various classification systems have been proposed for fractures of the distal radius, but the reliability of these classifications is seldom addressed. For a fracture classification to be useful, it must provide prognostic significance, interobserver reliability and intraobserver reproducibility. The aim here was to evaluate the intraobserver and interobserver agreement of distal radius fracture classifications. DESIGN AND SETTING: This was a validation study on interobserver and intraobserver reliability. It was developed in the Department of Orthopedics and Traumatology, Universidade Federal de Sao Paulo - Escola Paulista de Medicina. METHOD: X-rays from 98 cases of displaced distal radius fracture were evaluated by five observers: one third-year orthopedic resident (R3), one sixth-year undergraduate medical student (UG6), one radiologist physician (XRP), one orthopedic trauma specialist (OT) and one orthopedic hand surgery specialist (OHS). The radiographs were classified on three different occasions (times T1, T2 and T3) using the Universal (Cooney), Arbeitsgemeinschaft for Osteosynthesefragen/Association for the Study of Internal Fixation (AO/ASIF), Frykman and Fernandez classifications. The kappa coefficient (kappa) was applied to assess the degree of agreement. RESULTS: Among the three occasions, the highest mean intraobserver k was observed in the Universal classification (0.61), followed by Fernandez (0.59), Frykman (0.55) and AO/ASIF (0.49). The interobserver agreement was unsatisfactory in all classifications. The Fernandez classification showed the best agreement (0,44) and the worst was the Frykmam classification (0.26). CONCLUSION: The low agreement levels observed in this study suggest that there is A I no classification method with high reproducibility.
引用
收藏
页码:180 / 185
页数:6
相关论文
共 28 条
[1]   PREDICTION OF INSTABILITY OF COLLES FRACTURES [J].
ABBASZADEGAN, H ;
JONSSON, U ;
VONSIVERS, K .
ACTA ORTHOPAEDICA SCANDINAVICA, 1989, 60 (06) :646-650
[2]   Classification of distal radius fractures: An analysis of interobserver reliability and intraobserver reproducibility [J].
Andersen, DJ ;
Blair, WF ;
Steyers, CM ;
Adams, BD ;
ElKhouri, GY ;
Brandser, EA .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (04) :574-582
[3]  
[Anonymous], 2003, COCHRANE DATAB SYST, DOI DOI 10.1002/14651858.CD003763
[4]   Fractures of the distal radius (Colles' fracture) [J].
Belloti, Joao Carlos ;
Games dos Santos, Joao Baptista ;
Atallah, Alvaro Nagib ;
Albertoni, Walter Manna ;
Faloppa, Flavio .
SAO PAULO MEDICAL JOURNAL, 2007, 125 (03) :132-138
[6]   A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES [J].
COHEN, J .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) :37-46
[7]  
Colles A., 1814, EDINBURGH MED SURG J, V10, P181
[9]  
COONEY WP, 1993, ORTHOP CLIN N AM, V24, P211
[10]   EPIDEMIOLOGY OF FRACTURES OF THE DISTAL FOREARM IN OSLO, NORWAY [J].
FALCH, JA .
ACTA ORTHOPAEDICA SCANDINAVICA, 1983, 54 (02) :291-295