In Vivo MR Imaging of Pulmonary Perfusion and Gas Exchange in Rats via Continuous Extracorporeal Infusion of Hyperpolarized 129Xe

被引:20
作者
Cleveland, Zackary I. [1 ]
Moeller, Harald E. [1 ,2 ]
Hedlund, Laurence W. [1 ]
Nouls, John C. [1 ]
Freeman, Matthew S. [1 ,3 ]
Qi, Yi [1 ]
Driehuys, Bastiaan [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Ctr Vivo Microscopy, Durham, NC 27710 USA
[2] Max Planck Inst Human Cognit & Brain Sci, Leipzig, Germany
[3] Duke Univ, Grad Program Med Phys, Durham, NC USA
来源
PLOS ONE | 2012年 / 7卷 / 02期
基金
美国国家卫生研究院;
关键词
NUCLEAR-MAGNETIC-RESONANCE; LASER-POLARIZED XE-129; INERT-GAS; LUNG; XENON; NMR; VENTILATION; RELAXATION; MICROSCOPY; PROTEIN;
D O I
10.1371/journal.pone.0031306
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Hyperpolarized (HP) Xe-129 magnetic resonance imaging (MRI) permits high resolution, regional visualization of pulmonary ventilation. Additionally, its reasonably high solubility (> 10%) and large chemical shift range (> 200 ppm) in tissues allow HP Xe-129 to serve as a regional probe of pulmonary perfusion and gas transport, when introduced directly into the vasculature. In earlier work, vascular delivery was accomplished in rats by first dissolving HP Xe-129 in a biologically compatible carrier solution, injecting the solution into the vasculature, and then detecting HP Xe-129 as it emerged into the alveolar airspaces. Although easily implemented, this approach was constrained by the tolerable injection volume and the duration of the HP Xe-129 signal. Methods and Principal Findings: Here, we overcome the volume and temporal constraints imposed by injection, by using hydrophobic, microporous, gas-exchange membranes to directly and continuously infuse Xe-129 into the arterial blood of live rats with an extracorporeal (EC) circuit. The resulting gas-phase Xe-129 signal is sufficient to generate diffusive gas exchange-and pulmonary perfusion-dependent, 3D MR images with a nominal resolution of 2x2x2 mm(3). We also show that the Xe-129 signal dynamics during EC infusion are well described by an analytical model that incorporates both mass transport into the blood and longitudinal relaxation. Conclusions: Extracorporeal infusion of HP Xe-129 enables rapid, 3D MR imaging of rat lungs and, when combined with ventilation imaging, will permit spatially resolved studies of the ventilation-perfusion ratio in small animals. Moreover, EC infusion should allow Xe-129 to be delivered elsewhere in the body and make possible functional and molecular imaging approaches that are currently not feasible using inhaled HP Xe-129.
引用
收藏
页数:11
相关论文
共 59 条
  • [41] Molecular imaging using a targeted magnetic resonance hyperpolarized biosensor
    Schroeder, Leif
    Lowery, Thomas J.
    Hilty, Christian
    Wemmer, David E.
    Pines, Alexander
    [J]. SCIENCE, 2006, 314 (5798) : 446 - 449
  • [42] V/Q-scanning/SPECT for the diagnosis of pulmonary embolism
    Schümichen, C
    [J]. RESPIRATION, 2003, 70 (04) : 329 - 342
  • [43] Least-Square NUFFT Methods Applied to 2-D and 3-D Radially Encoded MR Image Reconstruction
    Song, Jiayu
    Liu, Yanhui
    Gewalt, Sally L.
    Cofer, Gary
    Johnson, G. Allan
    Liu, Qing Huo
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (04) : 1134 - 1142
  • [44] Quadrupolar relaxation of hyperpolarized krypton-83 as a probe for surfaces
    Stupic, KF
    Cleveland, ZI
    Pavlovskaya, GE
    Meersmann, T
    [J]. SOLID STATE NUCLEAR MAGNETIC RESONANCE, 2006, 29 (1-3) : 79 - 84
  • [45] Brain MRI with laser-polarized Xe-129
    Swanson, SD
    Rosen, MS
    Agranoff, BW
    Coulter, KP
    Welsh, RC
    Chupp, TE
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (05) : 695 - 698
  • [46] OXYGEN-INDUCED ALTERATION OF VENTILATION-PERFUSION RELATIONSHIPS IN RATS
    TRUOG, WE
    HLASTALA, MP
    STANDAERT, TA
    MCKENNA, HP
    HODSON, WA
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1979, 47 (05) : 1112 - 1117
  • [47] Unsworth J., 1971, Diffusion processes, P599
  • [48] Blood-gas exchange devices
    Voorhees, ME
    Brian, BF
    [J]. INTERNATIONAL ANESTHESIOLOGY CLINICS, 1996, 34 (02) : 29 - 45
  • [49] MORPHOMETRIC ESTIMATION OF PULMONARY DIFFUSION CAPACITY .6. EFFECT OF VARYING POSITIVE PRESSURE INFLATION OF AIR SPACES
    WEIBEL, ER
    UNTERSEE, P
    GIL, J
    ZULAUF, M
    [J]. RESPIRATION PHYSIOLOGY, 1973, 18 (03): : 285 - 308
  • [50] Designing microporous hollow fibre blood oxygenators
    Wickramasinghe, SR
    Han, B
    [J]. CHEMICAL ENGINEERING RESEARCH & DESIGN, 2005, 83 (A3) : 256 - 267