GC-MS/MS Determination of Steroid Hormones in Urine Using Solid-Phase Derivatization as an Alternative to Conventional Methods

被引:15
|
作者
Temerdashev, Azamat [1 ]
Nesterenko, Pavel [2 ]
Dmitrieva, Ekaterina [1 ]
Zhurkina, Kseniya [1 ]
Feng, Yu-Qi [3 ]
机构
[1] Kuban State Univ, Analyt Chem Dept, Stavropolskaya St 149, Krasnodar 350040, Russia
[2] Moscow MV Lomonosov State Univ, Phys Chem Dept, Leninskie Gory 1, Moscow 119991, Russia
[3] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
来源
MOLECULES | 2022年 / 27卷 / 18期
基金
俄罗斯科学基金会;
关键词
steroid hormones; androgens; estrogens; LLE; SPAD; GC-MS/MS; sample preparation; MASS-SPECTROMETRY METHOD; LIQUID-CHROMATOGRAPHY; TESTOSTERONE; METABOLITES; MATRICES; GC/MS;
D O I
10.3390/molecules27185796
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Solid-phase analytical derivatization (SPAD) is a promising hybrid sample preparation technique combining the clean-up and preconcentration of the sample in a single step. In this work, a novel SPAD method based on the preparation of trimethylsilyl (TMS) derivatives of steroid hormones (testosterone, estrone, DHT, estriol, estradiol, and progesterone) in Phenomenex Strata C18-E (100 mg, 1 mL) cartridges has been developed and applied for their GC-MS/MS determination in human urine samples. The proposed procedure allows the detection and quantification of steroids with limits of 1.0-2.5 and 2.5-5 ng/mL, respectively. These characteristics are comparable with those obtained with a conventional liquid-liquid extraction, while the recovery of analytes in the proposed SPAD procedure is higher. The major advantages of SPAD are a short derivatization time, high efficiency, and the possibility to automatize the procedure. However, its cost-effectiveness in routine practice is still questionable.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Determination of steroid hormones in blood by GC-MS/MS
    Hansen, Martin
    Jacobsen, Naja W.
    Nielsen, Frederik K.
    Bjorklund, Erland
    Styrishave, Bjarne
    Halling-Sorensen, Bent
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (10) : 3409 - 3417
  • [2] Optimization of solid-phase microextraction methods for GC-MS determination of terpenes in wine
    Peña, RM
    Barciela, J
    Herrero, C
    García-Martín, S
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 2005, 85 (07) : 1227 - 1234
  • [3] Determination of aldehydes in human breath by on-fibre derivatization, solid-phase microextraction and GC-MS
    Svensson, Sophie
    Larstad, Mona
    Broo, Klas
    Olin, Anna-Carin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 860 (01): : 86 - 91
  • [4] Analysis of methamphetamine in urine by GC/MS coupled with solid-phase dispersive extraction and solid-phase derivatization
    Saito, Koichi
    Segawa, Noriko
    Ito, Rie
    ANALYTICAL SCIENCES, 2025, 41 (01) : 85 - 92
  • [5] Determination of chlorophenols in sediment using ultrasonic solvent extraction followed by solid-phase extraction, derivatization, and GC-MS analysis
    Xu, Ming
    Gui, Lei
    Peng, Shu-Chuan
    Chen, Tian-Hu
    Wang, Ji-Zhong
    WATER QUALITY RESEARCH JOURNAL OF CANADA, 2017, 52 (02): : 90 - 98
  • [6] Simultaneous Derivatization of Hydroxyl and Ketone Groups for the Analysis of Steroid Hormones by GC-MS
    Fang, Kai
    Pan, Xuejun
    Huang, Bin
    Liu, Jingliang
    Wang, Yu
    Gao, Jianpei
    CHROMATOGRAPHIA, 2010, 72 (9-10) : 949 - 956
  • [7] Determination of Selected Cathinones in Blood by Solid-Phase Extraction and GC-MS
    Antunes, Monica
    Sequeira, Margarida
    Pereira, Mariana de Caires
    Caldeira, Maria Joao
    Santos, Susana
    Franco, Joao
    Barroso, Mario
    Gaspar, Helena
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2021, 45 (03) : 233 - 242
  • [8] Determination of steroid hormones in blood by GC–MS/MS
    Martin Hansen
    Naja W. Jacobsen
    Frederik K. Nielsen
    Erland Björklund
    Bjarne Styrishave
    Bent Halling-Sørensen
    Analytical and Bioanalytical Chemistry, 2011, 400 : 3409 - 3417
  • [9] Analysis of acidic pesticides using in situ derivatization with alkylchloroformate and solid-phase microextraction (SPME) for GC-MS
    Henriksen, T
    Svensmark, B
    Lindhardt, B
    Juhler, RK
    CHEMOSPHERE, 2001, 44 (07) : 1531 - 1539
  • [10] LC–MS/MS Determination of Catecholamines in Urine Using FMOC-Cl Derivatization on Solid-Phase Extraction Cartridge
    A. Azaryan
    T. Ligor
    B. Buszewski
    A. Temerdashev
    E. Dmitrieva
    E. Gashimova
    Chromatographia, 2018, 81 : 1487 - 1494