Pocket-size CdZnTe gamma-ray spectrometer

被引:4
作者
Luke, PN [1 ]
Amman, M [1 ]
Lee, JS [1 ]
Vu, CQ [1 ]
机构
[1] Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
关键词
gamma-ray spectroscopy detectors; semiconductor devices;
D O I
10.1109/TNS.2005.856732
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A pocket-size gamma-ray spectrometer has been developed. It uses a large volume (2 cm(3)) CdZnTe coplanar-grid detector to achieve good detection efficiency and energy resolution. The spectrometer is completely self-contained. It includes pulse processing electronics, multichannel analyzer, data storage, LCD display, keypads, USB interface, and rechargeable battery. Custom software was created for spectrum acquisition, storage, and display. The power consumption of the spectrometer is 120 mW when active, allowing two days of continuous operation on a full battery charge.
引用
收藏
页码:2041 / 2044
页数:4
相关论文
共 8 条
[1]   Electron trapping nonuniformity in high-pressure-Bridgman-grown CdZnTe [J].
Amman, M ;
Lee, JS ;
Luke, PN .
JOURNAL OF APPLIED PHYSICS, 2002, 92 (06) :3198-3206
[2]   Portable, low-power, mechanically cooled Ge spectrometer [J].
Becker, JA ;
Cork, CP ;
Fabris, L ;
Madden, NW .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2) :167-169
[3]   Multichannel CdZnTe gamma ray spectrometer [J].
Doty, FP ;
Lingren, CL ;
Apotovsky, BA ;
Brunsch, J ;
Butler, JF ;
Collins, T ;
Conwell, RL ;
Friesenhahn, S ;
Gormley, J ;
Pi, B ;
Zhao, S ;
Augustine, FL ;
Bennett, BA ;
Cross, E ;
James, RB .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3) :185-189
[4]   UNIPOLAR CHARGE SENSING WITH COPLANAR ELECTRODES - APPLICATION TO SEMICONDUCTOR-DETECTORS [J].
LUKE, PN .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :207-213
[5]   Noise reduction in CdZnTe coplanar-grid detectors [J].
Luke, PN ;
Lee, JS ;
Amman, M ;
Yu, KM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (04) :1950-1953
[6]   A CdZnTe coplanar-grid detector array for environmental remediation [J].
Luke, PN ;
Amman, M ;
Lee, JS ;
Ludewigt, BA ;
Yaver, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2) :319-324
[7]   Multielement CdTe stack detectors for gamma-ray spectroscopy [J].
Redus, R ;
Huber, A ;
Pantazis, J ;
Pantazis, T ;
Takahashi, T ;
Woolf, S .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) :2386-2394
[8]   Improved resolution for 3-d position sensitive CdZnTe spectrometers [J].
Zhang, F ;
He, Z ;
Xu, D ;
Knoll, GF ;
Wehe, DK ;
Berry, JE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) :2427-2431