Greater accuracy in positioning of the acetabular cup by using an image-free navigation system

被引:96
作者
Kalteis, T
Handel, M
Herold, T
Perlick, L
Baethis, H
Grifka, J
机构
[1] Dept Orthopaed Surg, D-93077 Bad Abbach, Germany
[2] Univ Regensburg, Dept Orthopaed Surg, Bad Abbach, Germany
[3] Univ Regensburg, Inst Radiol, Bad Abbach, Germany
关键词
D O I
10.1007/s00264-005-0671-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In a prospective and randomised clinical study, acetabular cups were implanted free-hand (control group n=22) or with computer assistance using an image-free navigation system (study group n=23). The cup position was determined postoperatively on pelvic CT. An average inclination of 42.3 degrees (range: 30 degrees-53 degrees; SD +/- 7.0 degrees) and an average anteversion of 24.0 degrees (range: -3 degrees to 51 degrees; SD +/- 15.0 degrees) were found in the control group, and an average inclination of 45.0 degrees (ranage: 40 degrees-50 degrees; SD +/- 2.8 degrees) and an average anteversion of 14.4 degrees (range: 5 degrees-25 degrees; SS +/- 5.0 degrees) in the computer-assisted study group. The deviations from the desired cup position (45 degrees inclination, 15 degrees anteversion) were significantly lower in the computer-assisted study group (p < 0.001 each). While only 11/22 of the cups in the control group were within the Lewinnek safe zone, 21/23 of the cups in the study group were placed in this target region (p=0.003).
引用
收藏
页码:272 / 276
页数:5
相关论文
共 20 条
[1]   The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321
[2]   Effects of acetabular abduction on cup wear rates in total hip arthroplasty [J].
Del Schutte, H ;
Lipman, AJ ;
Bannar, SM ;
Livermore, JT ;
Ilstrup, D ;
Morrey, BF .
JOURNAL OF ARTHROPLASTY, 1998, 13 (06) :621-626
[3]  
DeWal Hargovind, 2003, Am J Orthop (Belle Mead NJ), V32, P377
[4]   Accuracy of intraoperative assessment of acetabular prosthesis placement [J].
Hassan, DM ;
Johnston, GHF ;
Dust, WNC ;
Watson, G ;
Dolovich, AT .
JOURNAL OF ARTHROPLASTY, 1998, 13 (01) :80-84
[5]   Computer assisted measurement of cup placement in total hip replacement [J].
Jaramaz, B ;
DiGioia, AM ;
Blackwell, M ;
Nikou, C .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (354) :70-81
[6]  
Jaramaz B, 1998, CLIN ORTHOP RELAT R, V355, P8
[7]   Factors predisposing to dislocation after primary total hip arthroplasty - A multivariate analysis [J].
Jolles, BM ;
Zangger, P ;
Leyvraz, PF .
JOURNAL OF ARTHROPLASTY, 2002, 17 (03) :282-288
[8]  
JOLLES BM, 2004, CLIN ORTHOP RELAT R, V426, P174
[9]   Accuracy of an image-free cup navigation system -: an anatomical study [J].
Kalteis, T ;
Beckmann, J ;
Herold, T ;
Zysk, S ;
Bäthis, H ;
Perlick, L ;
Grifka, J .
BIOMEDIZINISCHE TECHNIK, 2004, 49 (09) :257-262
[10]   Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration [J].
Kennedy, JG ;
Rogers, WB ;
Soffe, KE ;
Sullivan, RJ ;
Griffen, DG ;
Sheehan, LJ .
JOURNAL OF ARTHROPLASTY, 1998, 13 (05) :530-534