Accuracy of Quantitative Computed Tomography Bone Mineral Density Measurements in Mandibles: A Cadaveric Study

被引:4
作者
Miguel-Sanchez, Alfonso [1 ]
Vilaplana-Vivo, Jaime [1 ]
Vilaplana-Vivo, Carlos [1 ]
Angel Vilaplana-Gomez, Juan [1 ]
Camacho-Alonso, Fabio [2 ]
机构
[1] Univ Murcia, Oral Surg, E-30001 Murcia, Spain
[2] Univ Murcia, Oral Med, E-30001 Murcia, Spain
关键词
bone mineral density; calibration bone phantom; computed tomography; BIOMECHANICAL ASPECTS; IMPLANT STABILITY; TITANIUM IMPLANTS; TRABECULAR BONE; CT; SITES; ASSESSMENTS; NAVIGATION; INSERTION; QUALITY;
D O I
10.1111/cid.12168
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposeThe aim was to investigate the accuracy of quantitative computed tomography bone mineral density (BMD) measurements in mandibles, comparing measured BMD with calibrated BMD. Materials and MethodsSeventy mandibles from adult cadavers were used. Twenty tomographic cuts were made in each mandible. In each tomographic cut, a region of interest was located, and the bone density was measured in Hounsfield unit (HU). A polymethyl methacrylate phantom containing four inserts of different predetermined densities (hydroxyapatite 100, 200, 500, and 700mg/cm(3)) was used to calculate calibrated bone density. Correlation between measured and calibrated bone densities was calculated. ResultsMean total correlation between measured and calibrated BMD in the 20 sagittal tomography cuts showed almost perfect positive correlation (r=0.998, p<.001). However, when average BMD measurements in HU were compared, the measured total BMD (in the 20 sagittal tomography cuts studied) was 54.99421.59, whereas the total calibrated BMD was 49.28 +/- 364.95, with statistically significant difference (p=.001). ConclusionsThere are discrepancies between measured and calibrated BMD; in this sense, a calibrated bone phantom with a predetermined mineral density should be used to determine the exact BMD before dental implants surgery.
引用
收藏
页码:693 / 699
页数:7
相关论文
共 50 条
  • [1] Bone Mineral Density Measurements of Lumbar Vertebrae by Quantitative Computed Tomography
    Riaz, Hassan
    Khan, Obaid Ullah
    Akram, Hamid
    RAWAL MEDICAL JOURNAL, 2009, 34 (01): : 4 - +
  • [2] Fractional quantitative computed tomography for bone mineral density evaluation - Accuracy, precision, and comparison to quantitative computed tomography
    Lee, J
    Shin, HI
    Kim, SY
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (04) : 566 - 571
  • [3] Quantitative Evaluation of Knee Subchondral Bone Mineral Density Using Cone Beam Computed Tomography
    Turunen, Mikael J.
    Toyras, Juha
    Kokkonen, Harri T.
    Jurvelin, Jukka S.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (10) : 2186 - 2190
  • [4] Assessment of Trabecular Bone Mineral Density Using Quantitative Computed Tomography in Normal Cats
    Cheon, Haengbok
    Choi, Wooshin
    Lee, Youngjae
    Lee, Donghoon
    Kim, Juhyung
    Kang, Ji-Houn
    Na, Kijeong
    Chang, Jinhwa
    Chang, Dongwoo
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2012, 74 (11) : 1461 - 1467
  • [5] Trabecular Bone Mineral Density Measurement Using Thoracic and Lumbar Quantitative Computed Tomography
    Budoff, Matthew J.
    Khairallah, Walid
    Li, Dong
    Gao, Yan Lin
    Ismaeel, Hussain
    Flores, Ferdinand
    Child, Janis
    Carson, Sivi
    Mao, Song Shou
    ACADEMIC RADIOLOGY, 2012, 19 (02) : 179 - 183
  • [6] Assessing bone mineral density in vivo: Quantitative computed tomography
    Korver, DR
    Saunders-Blades, JL
    Nadeau, KL
    POULTRY SCIENCE, 2004, 83 (02) : 222 - 229
  • [7] Quantitative computed tomography bone mineral density measurements in irradiated and non-irradiated minipig alveolar bone: an experimental study
    Verdonck, Henk W. D.
    Meijer, Gert J.
    Nieman, Fred H.
    Stoll, Christian
    Riediger, Dieter
    de Baat, Cees
    CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (05) : 465 - 468
  • [8] Accuracy of volumetric bone mineral density measurement in high-resolution peripheral quantitative computed tomography
    Sekhon, Kiranjit
    Kazakia, Galateia J.
    Burghardt, Andrew J.
    Hermannsson, Bryan
    Majumdar, Sharmila
    BONE, 2009, 45 (03) : 473 - 479
  • [9] Accuracy of single-energy quantitative computed tomography in the assessment of bone mineral density of cervical vertebrae
    Zink, PM
    Samii, M
    Luedemann, W
    Bellinzona, M
    Prokop, M
    EUROPEAN RADIOLOGY, 1997, 7 (09) : 1436 - 1440
  • [10] AGE-RELATED CHANGES OF BONE MINERAL DENSITY IN MANDIBLE BY QUANTITATIVE COMPUTED TOMOGRAPHY
    Du, X.
    Jiao, J.
    Cheng, X.
    Wang, L.
    Li, K.
    Liu, H.
    Wang, C.
    Arena, C.
    Zhurakivska, K.
    Guglielmi, G.
    Lo Muzio, L.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2017, 31 (04) : 997 - 1003