Test/Retest Reliability of Maximum Mouth Pressure Measurements With the MicroRPM in Healthy Volunteers

被引:84
作者
Dimitriadis, Zacharias [1 ,2 ]
Kapreli, Eleni [1 ]
Konstantinidou, Ioanna [1 ]
Oldham, Jacqueline [2 ]
Strimpakos, Nikolaos [1 ,2 ]
机构
[1] Technol Educ Inst Lamia, Physiotherapy Dept, Lamia, Greece
[2] Univ Manchester, Ctr Rehabil Sci, Manchester, Lancs, England
关键词
respiratory muscle; lung function; maximum expiratory pressure; maximum inspiratory pressure; manometer; reliability; RESPIRATORY MUSCLE FUNCTION; INSPIRATORY PRESSURE; NORMAL VALUES; REPRODUCIBILITY; DIAPHRAGM;
D O I
10.4187/respcare.00783
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Respiratory muscle strength is an important part of lung function. Assessment of the respiratory muscles' ability to generate force is important for recognizing respiratory muscle weakness in both sick and healthy people. OBJECTIVE: To assess the test/retest reliability of the MicroRPM portable manometer's measurements of maximum inspiratory pressure (MIP) and maximum expiratory pressure (MEP) in the sitting and standing positions; the number of expiratory maneuvers needed with the MicroRPM for reliability in MIP and MEP measurement; and the MicroRPM's test/retest reliability in other respiratory function indices, such as the maximum rate of pressure development (MRPD), the time constant of relaxation (tau), and the maximum relaxation rate (MRR). METHODS: We recruited 15 healthy volunteers (mean age 21.6 +/- 1.1 years). We assessed respiratory muscle strength on 3 separate occasions, each a week apart. We calculated reliability with the intraclass correlation coefficient (ICC), the standard error of measurement (SEM) and the smallest detectable difference (SDD). RESULTS: MicroRPM reliably measured MIP and MEP in both the sitting position (ICC 0.86-0.90, SEM 9-10, SDD 18-22) and standing position (ICC 0.78-0.83, SEM 12-14, SDD 23-26). After a 5-breath practice, 2 expiratory/inspiratory maneuvers on each testing occasion gave adequate MEP and MEP reliability (ICC > 0.90). MRR reliability was moderate to excellent (ICC 0.58-0.87), MRPD reliability was moderate (ICC 0.59-0.64), and tau reliability was insufficient (ICC 0.27-0.67). CONCLUSIONS: The MicroRPM reliably measures MIP and MEP, but its MRPD, MRR, and tau measurements should be considered with caution.
引用
收藏
页码:776 / 782
页数:7
相关论文
共 50 条
  • [1] The reliability and intensity dependence of maximum mouth pressure during bench press exercise in healthy athletes
    Blazek, Dusan
    Pisz, Anna
    Pecha, Ondrej
    Kubovy, Petr
    BALTIC JOURNAL OF HEALTH AND PHYSICAL ACTIVITY, 2020, 12 (01) : 1 - 10
  • [2] Test-retest reliability of DSC MRI CBV mapping in healthy volunteers
    Henry, ME
    Kaufman, MJ
    Lange, N
    Schmidt, ME
    Purcell, S
    Cote, J
    Perron-Henry, DM
    Stoddard, E
    Cohen, BM
    Renshaw, PF
    NEUROREPORT, 2001, 12 (08) : 1567 - 1569
  • [3] Test-retest reliability of a functional MRI anticipatory anxiety paradigm in healthy volunteers
    Schunck, Therese
    Erb, Gilles
    Mathis, Alexandre
    Jacob, Nathalie
    Gilles, Christian
    Namer, Izzie Jacques
    Meier, Dieter
    Luthringer, Remy
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (03) : 459 - 468
  • [4] Test-retest reliability and descriptive statistics of geometric measurements based on plantar pressure measurements in a healthy population during gait
    Akins, Jonathan S.
    Keenan, Karen A.
    Sell, Timothy C.
    Abt, John P.
    Lephart, Scott M.
    GAIT & POSTURE, 2012, 35 (01) : 167 - 169
  • [5] Test-retest reliability and responsiveness of centre of pressure measurements in patients with hip osteoarthritis
    Laroche, D.
    Kubicki, A.
    Stapley, P. J.
    Gremeaux, V.
    Mazalovic, K.
    Maillefert, J. -F.
    Ornetti, P.
    OSTEOARTHRITIS AND CARTILAGE, 2015, 23 (08) : 1357 - 1366
  • [6] Otoacoustic emission measurements: a test–retest reliability study
    Ayşenur Aykul Yağcıoğlu
    Burak Öztürk
    The Egyptian Journal of Otolaryngology, 39
  • [7] Test-retest reliability of cardiopulmonary exercise test-derived metrics in individuals with COPD versus healthy controls
    Mohammad, Milan
    Thomsen, Rie S.
    Rasmussen, Iben E.
    Andersen, Amalie B.
    Hartmann, Jacob P.
    Berg, Ronan M. G.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2025, 45 (01)
  • [8] Assessment of the test-retest reliability of human gingival blood flow measurements by Laser Speckle Contrast Imaging in a healthy cohort
    Molnar, Eszter
    Fazekas, Reka
    Lohinai, Zsolt
    Toth, Zsuzsanna
    Vag, Janos
    MICROCIRCULATION, 2018, 25 (02)
  • [9] Test-retest reliability of a new technique with pressure algometry applied to teeth in healthy Chinese individuals
    Liu, Ran
    Gu, Xinyu
    Zhang, Jinglu
    Yu, Linfeng
    Chen, Wenjing
    Wang, Kelun
    Svensson, Peter
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2016, 124 (03) : 259 - 265
  • [10] Otoacoustic emission measurements: a test-retest reliability study
    Yagcioglu, Aysenur Aykul
    Ozturk, Burak
    EGYPTIAN JOURNAL OF OTOLARYNGOLOGY, 2023, 39 (01)