The effect of model inclination during fabrication on mouthguard calliper-measured and CT scan-assessed thickness

被引:15
作者
Farrington, Timothy [1 ]
Coward, Trevor [2 ]
Onambele-Pearson, Gladys [1 ]
Taylor, Rebecca L. [3 ]
Earl, Philip [4 ]
Winwood, Keith [1 ]
机构
[1] Manchester Metropolitan Univ, Dept Exercise & Sport Sci Hlth, Exercise & Act Living HEAL Ctr, Crewe Green Rd, Crewe CW15DU, Cheshire, England
[2] Kings Coll London, Acad Ctr Reconstruct Sci, Dept Prosthet Facial Rehabil, London WC2R 2LS, England
[3] Manchester Metropolitan Univ, Sch Healthcare Sci, Fac Sci & Engn, Manchester, Lancs, England
[4] Worcestershire Royal Hosp, Worcester, England
关键词
mouthguards; angulation; thickness; thermoforming; PART; 1; SPORTS; FRACTURES; ETIOLOGY; FIT;
D O I
10.1111/edt.12213
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: Excessive material thinning has been observed in the production of custom-made mouthguards in a number of studies, due to production anomalies that may lead to such thinning. This study investigated thinning material patterns of custom-made mouthguards when the anterior angulation of dental model was increased during the thermoforming process. Materials and methods: A total of 60 samples of mouthguard blanks were thermoformed on identical maxillary models under four anterior inclination conditions (n = 4 x 15): control 0, 15, 30 and 45 degrees. Each mouthguard sample was measured, using an electronic calliper gauge at three anatomical points (anterior labial sulcus, posterior occlusion and posterior lingual). Mouthguards were then CT scanned to give a visual representation of the surface thickness. Results: Data showed a significant difference (P < 0.005) in the anterior mouthguard thickness between the four levels of anterior inclination, with the 45 degrees inclination producing the thickest mouthguards, increasing the mean anterior thickness by 75% (2.8 mm, SD: 0.16) from the model on a flat plane (1.6 mm, SD: 0.34). Anterior model inclination of 30 and 45 degrees inclinations increased consistencies between the thickest and thinnest mouthguards in the anterior region of these sample groups. Conclusion: This study highlights the importance of standardizing the thermoforming process, as this has a significant effect on the quality and material distribution of the resultant product. In particular, greater model inclination is advised as this optimizes the thickness of the anterior sulcus of the mouthguard which may be more prominently at risk from sport-related impact.
引用
收藏
页码:192 / 200
页数:9
相关论文
共 23 条
  • [11] Mills LF., 1964, ANGLE ORTHOD, V34, P124
  • [12] Thickness and fit of mouthguards according to heating methods
    Mizuhashi, Fumi
    Koide, Kaoru
    Takahashi, Mutsumi
    [J]. DENTAL TRAUMATOLOGY, 2014, 30 (01) : 60 - 64
  • [13] Thickness and fit of mouthguards according to a vacuum-forming process
    Mizuhashi, Fumi
    Koide, Kaoru
    Takahashi, Mutsumi
    [J]. DENTAL TRAUMATOLOGY, 2013, 29 (04) : 307 - 312
  • [14] A method to maintain the thickness of the mouthguard after the vacuum forming process: changes of the holding conditions of the mouthguard sheet
    Mizuhashi, Fumi
    Koide, Kaoru
    Takahashi, Mutsumi
    Mizuhashi, Ryo
    [J]. DENTAL TRAUMATOLOGY, 2012, 28 (04) : 291 - 295
  • [15] Newsome P, 2010, INT DENT AUSTRALAS E, V5, P64
  • [16] IMPROVING MOUTH GUARDS
    PARK, JB
    SHAULL, KL
    OVERTON, B
    DONLY, KJ
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1994, 72 (04) : 373 - 380
  • [17] Evaluation of laminated structures for sports mouthguards
    Patrick, D
    van Noort, R
    Found, MS
    [J]. EXPERIMENTAL TECHNIQUES AND DESIGN IN COMPOSITE MATERIALS 5, 2002, 221-2 : 133 - 143
  • [18] Scale of protection and the various types of sports mouthguard
    Patrick, DG
    van Noort, R
    Found, MS
    [J]. BRITISH JOURNAL OF SPORTS MEDICINE, 2005, 39 (05) : 278 - 281
  • [19] Variation in mouthguard thickness due to different heating conditions during fabrication
    Takahashi, Mutsumi
    Koide, Kaoru
    Mizuhashi, Fumi
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2013, 57 (03) : 179 - 185
  • [20] Difference in the thickness of mouthguards fabricated from ethylene-vinyl acetate co-polymer sheets with differently arranged v-shaped grooves
    Takahashi, Mutsumi
    Koide, Kaoru
    Mizuhashi, Fumi
    [J]. JOURNAL OF PROSTHODONTIC RESEARCH, 2013, 57 (03) : 169 - 178