Evaluation of the American College of Cardiology Foundation/American Society of Nuclear Cardiology appropriateness criteria for SPECT myocardial perfusion imaging

被引:69
作者
Mehta, Rupa [1 ]
Ward, R. Parker [1 ]
Chandra, Sonal [1 ]
Agarwal, Richa [1 ]
Williams, Kim Allan [1 ]
机构
[1] Univ Chicago, Chicago, IL 60637 USA
关键词
single photon emission computed tomography; appropriateness criteria;
D O I
10.1016/j.nuclcard.2007.10.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The American College of Cardiology Foundation/American Society of Nuclear Cardiology appropriateness criteria (AC) were created to guide responsible use of single photon emission computed tomography (SPECT). Clinical applicability of the AC has not been evaluated. Methods and Results. Indications for testing were determined in 1209 patients and categorized as having appropriate, uncertain, or inappropriate indications; the specialty of the ordering physician was noted. There were 940 (80%) appropriate, 154 (13%) inappropriate, and 79 (7%) uncertain tests; 36 tests were labeled "no category," as these were ordered for indications not clearly addressed in the AC. Inappropriate studies had more normal and lower summed stress scores, although there remained a high proportion of abnormal SPECT studies in this group (26% of women and 50% of men). Women had lower summed stress scores and more normal tests in the appropriate and inappropriate groups. Studies ordered by anesthesiologists for preoperative evaluation were more likely to be deemed inappropriate than other specialty groups. Conclusion. In evaluating the AC in a single-center academic setting, the majority of studies are appropriate, but a large proportion of ordered SPECT studies were categorized as uncertain, inappropriate, or no category. Although the inappropriate studies showed less ischemia than other groups, especially in women, a substantial portion of these studies (32%) were abnormal.
引用
收藏
页码:337 / 344
页数:8
相关论文
共 13 条
[1]   ACCF/ASNC appropriateness criteria for single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) - A report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group and the American Society of Nuclear Cardiology [J].
Brindis, RG ;
Douglas, PS ;
Hendel, RC ;
Peterson, ED ;
Wolk, MJ ;
Allen, JM ;
Patel, MR ;
Raskin, IE ;
Hendel, RC ;
Bateman, TM ;
Cerqueira, MD ;
Gibbons, RJ ;
Gillam, LD ;
Gillespie, JA ;
Hendel, RC ;
Iskandrian, AE ;
Jerome, SD ;
Krumholz, HM ;
Messer, JV ;
Spertus, JA ;
Stowers, SA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (08) :1587-1605
[2]   ACC/AHA guideline update for perioperative cardiovascular evaluation for noncardiac surgery - Executive summary [J].
Eagle, KA ;
Berger, PB ;
Calkins, H ;
Chaitman, BR ;
Ewy, GA ;
Fleischmann, KE ;
Fleisher, LA ;
Froehlich, JB ;
Gusberg, RJ ;
Leppo, JA ;
Ryan, T ;
Schlant, RC ;
Winters, WL ;
Gibbons, RJ ;
Antman, EM ;
Alpert, JS ;
Faxon, DP ;
Fuster, V ;
Gregoratos, G ;
Jacobs, AK ;
Hiratzka, LF ;
Russell, RO ;
Smith, SC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (03) :542-553
[3]   ACC/AHA 2002 guideline update for exercise testing: Summary article - A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee to Update the 1997 Exercise Testing Guidelines) [J].
Gibbons, RJ ;
Balady, GJ ;
Bricker, JT ;
Chaitman, BR ;
Fletcher, GF ;
Froelicher, VF ;
Mark, DB ;
McCallister, BD ;
Mooss, AN ;
O'Reilly, MG ;
Winters, WL ;
Antman, EM ;
Alpert, JS ;
Faxon, DP ;
Fuster, V ;
Gregoratos, G ;
Hiratzka, LF ;
Jacobs, AK ;
Russell, RO ;
Smith, SC .
CIRCULATION, 2002, 106 (14) :1883-1892
[4]  
Hachamovitch R, 1998, CIRCULATION, V97, P535
[5]  
*IMV MED INF DIV, 2005, 2005 NUCL MED MARK S
[6]  
*IMV MED INF DIV, 2003, 2003 NUCL MED MARK S
[7]   INDEPENDENT AND INCREMENTAL PROGNOSTIC VALUE OF EXERCISE SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHIC (SPECT) THALLIUM IMAGING IN CORONARY-ARTERY DISEASE [J].
ISKANDRIAN, AS ;
CHAE, SC ;
HEO, JY ;
STANBERRY, CD ;
WASSERLEBEN, V ;
CAVE, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (03) :665-670
[8]   ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging - Executive summary - A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to revise the 1995 guidelines for the clinical use of cardiac radionuclide imaging) [J].
Klocke, FJ ;
Baird, MG ;
Lorell, BH ;
Bateman, TM ;
Messer, JV ;
Berman, DS ;
O'Gara, PT ;
Carabello, BA ;
Russell, RO ;
Cerqueira, MD ;
Sutton, MGS ;
DeMaria, AN ;
Udelson, JE ;
Kennedy, JW ;
Verani, MS ;
Williams, KA ;
Antman, EM ;
Smith, SC ;
Alpert, JS ;
Gregoratos, G ;
Anderson, JL ;
Hiratzka, LF ;
Faxon, DP ;
Hunt, SA ;
Fuster, V ;
Jacobs, AK ;
Gibbons, RJ ;
Russell, RO .
CIRCULATION, 2003, 108 (11) :1404-1418
[9]   ACC/AHA/ASNC uidelines for the clinical use of cardiac radionuclide imaging - Executive summary - A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to revise the 1995 guidelines for the clinical use of cardiac radionuclide imaging) [J].
Klocke, FJ ;
Baird, MG ;
Lorell, BH ;
Bateman, TM ;
Messer, JV ;
Berman, DS ;
O'Gara, PT ;
Carabello, BA ;
Russell, RO ;
Cerqueira, MD ;
Sutton, MGS ;
DeMaria, AN ;
Udelson, JE ;
Kennedy, JW ;
Verani, MS ;
Williams, KA ;
Antman, EM ;
Smith, SC ;
Alpert, JS ;
Gregoratos, G ;
Anderson, JL ;
Hiratzka, LF ;
Faxon, DP ;
Hunt, SA ;
Fuster, V ;
Jacobs, AK ;
Gibbons, RJ ;
Russell, RO .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (07) :1318-1333
[10]  
KOENIG L, 2005, ISSUES GROWTH DIAGNO