Performance analysis of solar air heater with jet impingement on corrugated absorber plate

被引:107
作者
Aboghrara, Alsanossi M. [1 ,3 ]
Baharudin, B. T. H. T. [1 ]
Alghoul, M. A. [2 ]
Adam, Nor Mariah [1 ]
Hairuddin, A. A. [1 ]
Hasan, Husam A. [2 ]
机构
[1] Univ Putra Malaysia, Fac Engn, Mech Dept, Serdang 43400, Selangor, Malaysia
[2] UKM, Solar Energy Res Inst, Bangi 43600, Selangor, Malaysia
[3] Univ Sebha, Fac Sci Traghen, Phys Dept, Sabha, Libya
关键词
Solar air heater; Jet impingement; Corrugated plat; Outlet temperature; Efficiency; DESIGN;
D O I
10.1016/j.csite.2017.04.002
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper deals with the experimental investigation outlet temperature and efficiency, of Solar Air heater (SAH). The experimental test set up designed and fabricated to study the effect of jet impingement on the corrugated absorber plate, through circular jets in a duct flow of solar air heater, and compared with conventional solar air heater on flat plat absorber. Under effect of mass flow rate ((m) over dot) of air and solar radiation on outlet air temperature, and efficiency, are analyzed. Results show the flow jet impingement on corrugated plat absorber is a strong function of heat transfer enhancement. The present investigation concludes that the mass flow rate of air substantially influences the heat transfer on solar air heaters. And the thermal efficiency of proposed design duct is observed almost 14% more as compare to the smooth duct. M solar radiation 500-1000 (W/M-2), 308 K ambient temperature and 0.01-0.03 (K-g/S) mass flow rate
引用
收藏
页码:111 / 120
页数:10
相关论文
共 23 条
[1]   Solar air heater applications in India [J].
Bansal, NK .
RENEWABLE ENERGY, 1999, 16 (1-4) :618-623
[2]   Performance of jet impingement in unglazed air collectors [J].
Belusko, M. ;
Saman, W. ;
Bruno, F. .
SOLAR ENERGY, 2008, 82 (05) :389-398
[3]   Heat transfer and friction factor correlations for impinging jet solar air heater [J].
Chauhan, Ranchan ;
Thakur, N. S. .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2013, 44 :760-767
[4]   EVALUATION OF A JET PLATE SOLAR AIR HEATER [J].
CHOUDHURY, C ;
GARG, HP .
SOLAR ENERGY, 1991, 46 (04) :199-209
[5]   The role of climatic-design-operational parameters on combined PV/T collector performance: A critical review [J].
Elbreki, A. M. ;
Alghoul, M. A. ;
Al-Shamani, A. N. ;
Ammar, A. A. ;
Yegani, Bita ;
Aboghrara, Alsanossi M. ;
Rusaln, M. H. ;
Sopian, K. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 57 :602-647
[6]  
Florschuetz Metzger, 1981, 3373 NASA
[7]   Analytical and experimental studies on the thermal performance of cross-corrugated and flat-plate solar air heaters [J].
Gao, Wenfeng ;
Lin, Wenxian ;
Liu, Tao ;
Xia, Chaofeng .
APPLIED ENERGY, 2007, 84 (04) :425-441
[8]  
Goel A.K., 2014, INT J ENERGY TECHNOL, V6, P1
[9]   EXPERIMENTS ON TRANSFER CHARACTERISTICS OF A CORRUGATED FIN AND TUBE HEAT-EXCHANGER CONFIGURATION [J].
GOLDSTEIN, L ;
SPARROW, EM .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1976, 98 (01) :26-34
[10]   HEAT-MASS TRANSFER CHARACTERISTICS FOR FLOW IN A CORRUGATED WALL CHANNEL [J].
GOLDSTEIN, L ;
SPARROW, EM .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1977, 99 (02) :187-195