Combination of a multimode sample introduction system with a pre-evaporation tube to improve multi-element analysis by ICP-OES

被引:28
作者
Asfaw, Alemayehu [1 ]
Beauchemin, Diane [1 ]
机构
[1] Queens Univ, Dept Chem, Kingston, ON K7L 3N6, Canada
关键词
INDUCTIVELY-COUPLED PLASMA; ATOMIC-EMISSION-SPECTROMETRY; CHEMICAL-VAPOR GENERATION; HYDRIDE-FORMING ELEMENTS; MASS-SPECTROMETRY; OPERATING-CONDITIONS; NOBLE-METALS; INTERNAL STANDARDIZATION; ULTRASONIC NEBULIZATION; ANALYTICAL-CHEMISTRY;
D O I
10.1039/c1ja10224a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A pre-evaporation tube (heated to 400 degrees C) was inserted between a multi-mode sample introduction system (MSIS) and the plasma torch in inductively coupled plasma optical emission spectrometry (ICP-OES) to improve the simultaneous determination of hydride-forming and other elements. Multivariate optimisations were conducted to find operating conditions improving plasma robustness. Under these conditions and compared to conventional sample introduction with a pneumatic nebulizer and spray chamber, using MSIS with a pre-evaporation tube (PET) improved sensitivity and detection limits for hydride-forming elements (As, Sn, Hg, Sb and Bi) and other elements as well. In order to obtain a significant improvement for all elements, irrespective of hydride formation or not, the pneumatic nebulizer was replaced by an ultrasonic nebulizer (USN) and the same experimental conditions were used for the simultaneous introduction of aerosol and hydrides (from the MSIS) into a PET. With USN-MSIS-PET, the figures of merit of ICP-OES improved by over an order of magnitude for both hydride-forming elements and other elements compared to those with a conventional sample introduction system. Furthermore, using either PN-MSIS-PET or USN-MSIS-PET increased plasma robustness, likely as a result of the hydrogen gas by-product of hydride generation, which was reported to increase energy transfer within the plasma, and from the introduction of water vapor (with PET), which was reported to improve plasma stability as well as sensitivity. Good agreement with certified values was obtained when this approach was applied to the determination of hydride-forming and other elements in environmental certified reference materials.
引用
收藏
页码:80 / 91
页数:12
相关论文
共 61 条
[1]   Simultaneous determination of hydride (Se) and non-hydride-forming (Ca, Mg, K, P, S and Zn) elements in various beverages (beer, coffee, and milk), with minimum sample preparation, by ICP-AES and use of a dual-mode sample-introduction system [J].
Asfaw, A ;
Wibetoe, G .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (01) :173-179
[2]   A new demountable hydrofluoric acid resistant triple mode sample introduction system for ICP-AES and ICP-MS [J].
Asfaw, Alemayehu ;
Wibetoe, Grethe .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (02) :158-163
[3]   Dual mode sample introduction for multi-element determination by ICP-MS:: the optimization and use of a method based on simultaneous introduction of vapor formed by NaBH4 reaction and aerosol from the nebulizer [J].
Asfaw, Alemayehu ;
Wibetoe, Grethe .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (10) :1027-1035
[4]   Improvement of the capabilities of inductively coupled plasma optical emission spectrometry by replacing the desolvation system of an ultrasonic nebulization system with a pre-evaporation tube [J].
Asfaw, Alemayehu ;
Beauchemin, Diane .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (05) :376-384
[5]   Inductively coupled plasma mass spectrometry [J].
Beauchemin, Diane .
ANALYTICAL CHEMISTRY, 2008, 80 (12) :4455-4486
[6]   Evaluation of dual sample introduction systems by comparison of cyclonic spray chambers with different entrance angles for ICP-OES [J].
Benzo, Zully ;
Maldonado, Domingo ;
Chirinos, Jose ;
Marcano, Eunice ;
Gomez, Clara ;
Quintal, Manuelita ;
Salas, Janeth .
MICROCHEMICAL JOURNAL, 2009, 93 (02) :127-132
[7]   Response surface methodology (RSM) as a tool for optimization in analytical chemistry [J].
Bezerra, Marcos Almeida ;
Santelli, Ricardo Erthal ;
Oliveira, Eliane Padua ;
Villar, Leonardo Silveira ;
Escaleira, Luciane Amlia .
TALANTA, 2008, 76 (05) :965-977
[8]   THE VERTICAL SPATIAL CHARACTERISTICS OF ANALYTE EMISSION IN THE INDUCTIVELY COUPLED PLASMA [J].
BLADES, MW ;
HORLICK, G .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1981, 36 (09) :861-880
[9]   INTERFERENCE FROM EASILY IONIZABLE ELEMENT MATRICES IN INDUCTIVELY COUPLED PLASMA EMISSION-SPECTROMETRY - A SPATIAL STUDY [J].
BLADES, MW ;
HORLICK, G .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1981, 36 (09) :881-900
[10]   Comparison of pneumatic and ultrasonic nebulizations in inductively coupled plasma atomic emission spectrometry - matrix effects and plasma parameters [J].
Borkowska-Burnecka, Jolanta ;
Lesniewicz, Anna ;
Zymicki, Wieslaw .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (05) :579-587