Macrophage accumulation associated with rat cardiac allograft rejection detected by magnetic resonance imaging with ultrasmall superparamagnetic iron oxide particles

被引:104
|
作者
Kanno, S
Wu, YJL
Lee, PC
Dodd, SJ
Williams, M
Griffith, BP
Ho, C
机构
[1] Carnegie Mellon Univ, Dept Biol Sci, Pittsburgh, PA 15213 USA
[2] Carnegie Mellon Univ, Pittsburgh NMR Ctr Biomed Res, Pittsburgh, PA 15213 USA
[3] Univ Pittsburgh, Dept Surg, Pittsburgh, PA 15260 USA
关键词
magnetic resonance imaging; rejection; diagnosis; transplantation;
D O I
10.1161/hc3401.093148
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Acute cardiac allograft rejection continues to be the cause of graft loss and contributes to the morbidity and mortality after cardiac transplantation. In this study, we report a new method for detecting organ rejection in transplantation with an MR-based technique using dextran-coated ultrasmall superparamagnetic iron oxide (USPIO) particles. These particles (approximate to 27 nm in diameter) are known to shorten relaxation times in MRI experiments. Methods and Results-A new rat model of heterotopic heart and lung transplantation has been developed for MRI experiments. Allotransplantations (DA --> BN) were performed (n = 8), with syngeneic transplantations (BN --> BN) serving as controls (n = 8). MR images were obtained with a gradient echo method. At postoperative day 7, allotransplants developed moderate rejection as determined histopathologically. A significant reduction in MR signal intensity was observed after USPIO injection into rats with allotransplanted hearts. Syngeneic transplants showed no differences in MR signal intensity before and after USPIO injections. After injection of USPIO particles at postoperative. day 6, a group of allotransplanted rats was treated with cyclosporin A (3 mg/kg). Animals treated with cyclosporin A for 7 days showed no reduction in MR signal intensity after USPIO reinjection at day 14, whereas animals treated for 4 days showed a significant decrease in MR signal intensity in the transplanted hearts indicative of acute gr aft rejection. Pathological analysis of these animals revealed that dextran-coated USPIO particles were taken up by the infiltrating macrophages that accumulated within the rejecting cardiac graft. Conclusions-This MRI method offers promise as a noninvasive method for detecting transplant allograft rejection.
引用
收藏
页码:934 / 938
页数:5
相关论文
共 50 条
  • [1] Accumulation of ultrasmall superparamagnetic particles of iron oxide in human atherosclerotic plaques can be detected by in vivo magnetic resonance imaging
    Kooi, ME
    Cappendijk, VC
    Cleutjens, KBJM
    Kessels, AGH
    Kitslaar, PJEHM
    Borgers, M
    Frederik, PM
    Daemen, MJAP
    van Engelshoven, JMA
    CIRCULATION, 2003, 107 (19) : 2453 - 2458
  • [2] Ultrasmall Superparamagnetic Particles of Iron Oxide and Cardiac Magnetic Resonance: Novel Imaging in Everyday Conditions
    Tsampasian, Vasiliki
    Merinopoulos, Ioannis
    Cameron, Donnie
    Garg, Pankaj
    Vassiliou, Vassilios S.
    APPLIED SCIENCES-BASEL, 2022, 12 (14):
  • [3] Magnetic resonance imaging of ruptured plaques in the rabbit with ultrasmall superparamagnetic particles of iron oxide
    Durand, E.
    Raynaud, J. S.
    Bruneval, P.
    Brigger, I.
    Al Haj Zen, A.
    Mandet, C.
    Lancelot, E.
    Lafont, A.
    JOURNAL OF VASCULAR RESEARCH, 2007, 44 (02) : 119 - 128
  • [4] Magnetic resonance imaging of ruptured plaques in rabbit with ultrasmall superparamagnetic particles of iron oxide
    Durand, E.
    Raynaud, J. S.
    Bruneval, P.
    Brigger, I.
    Zen, A. Al Haj
    Mandet, C.
    Lancelot, E.
    Lafont, A.
    EUROPEAN HEART JOURNAL, 2006, 27 : 422 - 422
  • [5] Magnetic resonance imaging of atherosclerotic plaque with ultrasmall superparamagnetic particles of iron oxide in hyperlipidemic rabbits
    Ruehm, SG
    Corot, C
    Vogt, P
    Kolb, S
    Debatin, JF
    CIRCULATION, 2001, 103 (03) : 415 - 422
  • [6] Magnetic resonance imaging of experimental atherosclerotic plaque: Comparison of two ultrasmall superparamagnetic particles of iron oxide
    Herborn, Christoph U.
    Vogt, Florian M.
    Lauenstein, Thomas C.
    Dirsch, Olaf
    Corot, Claire
    Robert, Philippe
    Ruehm, Stefan G.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (02) : 388 - 393
  • [7] Ultrasmall Superparamagnetic Iron Oxide Nanoparticles for Magnetic Resonance Imaging Contrast Agent
    Zhao, Xueling
    Zhao, Hongli
    Chen, Zongyan
    Lan, Minbo
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2014, 14 (01) : 210 - 220
  • [8] Quantification of macrophage infiltration after aortic balloon angioplasty in the hypercholesterolemic rabbit using ultrasmall superparamagnetic particles of iron oxide and magnetic resonance imaging
    Hyafil, F
    Laissy, JP
    Mazighi, M
    Adle-Biassette, H
    Henin, D
    Jacob, MP
    Letourneur, D
    Feldman, LJ
    EUROPEAN HEART JOURNAL, 2004, 25 : 335 - 336
  • [9] Magnetic Resonance Imaging of Abdominal Aortic Aneurysms (AAA) Using Ultrasmall Superparamagnetic Particles of Iron Oxide (USPIO)
    Richards, Jennifer M.
    Semple, Scott I.
    Gray, Calum
    McKillop, Graham
    Chalmers, Roderick T.
    Garden, Olivier J.
    Newby, David E.
    JOURNAL OF VASCULAR SURGERY, 2010, 51 : 48S - 48S
  • [10] Macrophage imaging in central nervous system and in carotid atherosclerotic plaque using ultrasmall superparamagnetic iron oxide in magnetic resonance imaging
    Corot, C
    Petry, KG
    Trivedi, R
    Saleh, A
    Jonkmanns, C
    Le Bas, JF
    Blezer, E
    Rausch, M
    Brochet, B
    Foster-Gareau, P
    Balériaux, D
    Gaillard, S
    Dousset, V
    INVESTIGATIVE RADIOLOGY, 2004, 39 (10) : 619 - 625