Suitability of an Orbitrap Mass Spectrometer for the Screening of Pesticide Residues in Extracts of Fruits and Vegetables

被引:28
作者
Alder, Lutz [1 ]
Steinborn, Angelika [1 ]
Bergelt, Sebastian [1 ]
机构
[1] Fed Inst Risk Assessment, D-14191 Berlin, Germany
关键词
EMERGING CONTAMINANTS; LTQ-ORBITRAP; OF-FLIGHT; FOOD; MATRICES; IDENTIFICATION; CHROMATOGRAPHY; QUADRUPOLE; SAMPLES; FEED;
D O I
10.5740/jaoacint.SGEAlder
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For about 500 pesticides, the sensitivity of a benchtop high-resolution mass spectrometer using the Orbitrap for mass separation was compared to that of a widely used (low-resolution) tandem mass spectrometer. Both instruments were coupled to LC and used electrospray ionization. The selectivity of the Orbitrap in the full-scan acquisition mode without fragmentation was evaluated at a resolution of 100 000 full width at half maximum for all pesticides detectable with sufficient sensitivity. For this purpose, quasimolecular ions were extracted within 5 ppm windows from total ion chromatograms of two types of extracts of cucumber, lemon, wheat flour, raisin, and tea. In each of the obtained reconstructed ion chromatograms (individual chromatograms for 500 pesticides, each pesticide in 10 different extracts) the sum of signals not arising from the analyte was used to get a measure on selectivity. In addition, the target analyte list was checked for ions of similar mass. The influence of matrix on the ability to detect low concentrations of fortified pesticides was also studied, with the help of spiked extracts. This part of the survey tested whether analyte peaks were lost because of insufficient mass resolution or an early closing C-Trap (used to control the ion current into the Orbitrap). Finally, the stability of the ion ratio [M+H](+)/[M+Na](+) was tested, which may be helpful to confirm the identity of an analyte.
引用
收藏
页码:1661 / 1673
页数:13
相关论文
共 26 条
[11]   Post-interface signal suppression, a phenomenon observed in a single-stage Orbitrap mass spectrometer coupled to an electrospray interfaced liquid chromatograph [J].
Kaufmann, A. ;
Widmer, M. ;
Maden, K. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (14) :2162-2170
[12]   Full Scan MS in Comprehensive Qualitative and Quantitative Residue Analysis in Food and Feed Matrices: How Much Resolving Power is Required? [J].
Kellmann, Markus ;
Muenster, Helmut ;
Zomer, Paul ;
Mol, Hans .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (08) :1464-1476
[13]   High-resolution extracted ion chromatography, a new tool for metabolomics and lipidomics using a second-generation orbitrap mass spectrometer [J].
Koulman, Albert ;
Woffendin, Gary ;
Narayana, Vinod K. ;
Welchman, Helen ;
Crone, Catharina ;
Volmer, Dietrich A. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (10) :1411-1418
[14]   LC-high resolution MS in environmental analysis: from target screening to the identification of unknowns [J].
Krauss, Martin ;
Singer, Heinz ;
Hollender, Juliane .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (03) :943-951
[15]  
Lehotay SJ, 2007, J AOAC INT, V90, P485
[16]   Toward a Generic Extraction Method for Simultaneous Determination of Pesticides, Mycotoxins, Plant Toxins, and Veterinary Drugs in Feed and Food Matrixes [J].
Mol, Hans G. J. ;
Plaza-Bolanos, Patricia ;
Zomer, Paul ;
de Rijk, Theo C. ;
Stolker, Alida A. M. ;
Mulder, Patrick P. J. .
ANALYTICAL CHEMISTRY, 2008, 80 (24) :9450-9459
[17]   Screening and confirmation criteria for hormone residue analysis using liquid chromatography accurate mass time-of-flight, Fourier transform ion cyclotron resonance and orbitrap mass spectrometry techniques [J].
Nielen, M. W. F. ;
van Engelen, M. C. ;
Zuiderent, R. ;
Ramaker, R. .
ANALYTICA CHIMICA ACTA, 2007, 586 (1-2) :122-129
[18]   Environmental and food applications of LC-tandem mass spectrometry in pesticide-residue analysis:: An overview [J].
Picó, Y ;
Blasco, C ;
Font, G .
MASS SPECTROMETRY REVIEWS, 2004, 23 (01) :45-85
[19]   Method validation and comparison of acetonitrile and acetone extraction for the analysis of 169 pesticides in soya grain by liquid chromatography-tandem mass spectrometry [J].
Pizzutti, Ionara R. ;
de Kok, Andre ;
Hiemstra, Maurice ;
Wickert, Cristine ;
Prestes, Osmar D. .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (21) :4539-4552
[20]   Comparison of triple quadrupole, hybrid linear ion trap triple quadrupole, time-of-flight and LTQ-Orbitrap mass spectrometers in drug discovery phase metabolite screening and identification in vitro - amitriptyline and verapamil as model compounds [J].
Rousu, Timo ;
Herttuainen, Jukka ;
Tolonen, Ari .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (07) :939-957