Study of n-γ discrimination by zero-crossing method with SiPM based scintillation detectors

被引:17
作者
Grodzicka-Kobylka, M. [1 ]
Szczesniak, T. [1 ]
Moszynski, M. [1 ]
Swiderski, L. [1 ]
Wolski, D. [1 ]
Baszak, J. [2 ]
Korolczuk, S. [1 ]
Schotanus, P. [3 ]
机构
[1] Natl Ctr Nucl Res, A Soltana 7, PL-05400 Otwock, Poland
[2] Hamamatsu Photon Deutschland GmbH, Arzbergerstr 10, D-82211 Herrsching, Germany
[3] Scionix, POB 143, NL-3980 CC Bunnik, Netherlands
关键词
n/gamma discrimination; Stilbene; EJ299-33; plastic; MPPC arrays; PULSE-SHAPE DISCRIMINATION; SILICON PHOTOMULTIPLIERS; ORGANIC SCINTILLATORS; LIQUID SCINTILLATORS; NEUTRON DETECTORS; PERFORMANCE; READOUT; TESTS; PET;
D O I
10.1016/j.nima.2017.11.045
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The paper presents a study of n/gamma discrimination with 4x4 ch and 8x8 ch Multi Pixel Photon Counter (MPPC) arrays in neutron detectors based on Stilbene and EJ299-33 plastic scintillators. The n/gamma discrimination showed an excellent capability of the MPPC arrays, comparable to that observed earlier with the classical PMTs. Particularly, an application of a zero-crossing method of n - gamma discrimination prevented deterioration of the discrimination by the slow response of the Silicon Photomultiplier (SiPM, or MPPC interchangeably) array related to its large capacitance. It was confirmed by a good agreement of the Figure of Merit normalized to the number of photoelectrons determined for the MPPC arrays and XP5500 PMT. (c) 2017 Published by Elsevier B.V.
引用
收藏
页码:159 / 165
页数:7
相关论文
共 31 条
[1]  
[Anonymous], 1964, THEORY PRACTICE SCIN
[2]  
Bertolaccini S., 1968, P NUCL EL S VERS FRA
[3]   A PULSE SHAPE DISCRIMINATOR WITH HIGH-PRECISION OF NEUTRON AND GAMMA-RAY SELECTION AT HIGH COUNTING RATE [J].
BIALKOWSKI, J ;
MOSZYNSKI, M ;
WOLSKI, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 275 (02) :322-328
[4]   DEVELOPMENT OF ORGANIC SCINTILLATORS [J].
BROOKS, FD .
NUCLEAR INSTRUMENTS & METHODS, 1979, 162 (1-3) :477-505
[5]  
Degenhardt C, 2012, IEEE NUCL SCI CONF R, P2820
[6]   Characterization of 4x4 ch MPPC array in scintillation spectrometry [J].
Grodzicka, M. ;
Moszynski, M. ;
Szczesniak, T. ;
Szawlowski, M. ;
Baszak, J. .
JOURNAL OF INSTRUMENTATION, 2013, 8
[7]   MPPC Array in the Readout of CsI:Tl, LSO:Ce:Ca, LaBr3:Ce, and BGO Scintillators [J].
Grodzicka, M. ;
Moszynski, M. ;
Szczesniak, T. ;
Szawlowski, M. ;
Wolski, D. ;
Baszak, J. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (06) :3294-3303
[8]  
Grodzicka M., 2017, NUCL INSTRUM M UNPUB
[9]  
Grodzicka M., 2014, P IEEE NUCL SCI S ME
[10]  
Grodzicka M., 2013, J INSTRUM, V8