Capacitance-Based Monitoring of a Three-Phase Crude-Oil Flow

被引:5
|
作者
Sheikh, Sharif Iqbal M. [1 ]
Hassan, Essam E. M. [1 ]
Iqbal, Sajid [2 ]
机构
[1] KFUPM, Elect Engn Dept, Dhahran 31261, Saudi Arabia
[2] Fast Natl Univ, Elect Engn Dept, Islamabad, Pakistan
关键词
Capacitance meter; semicylindrical capacitor; three phase; volumetric flow;
D O I
10.1109/TIM.2019.2909941
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A simple solution is presented for identifying the phase fraction and flow rate of a petroleum carrying pipeline with three-phase stratified smooth and wavy flow. The proposed method mounts a set of semicylindrical electrodes on the internal surface of the Plexiglas pipe to monitor the total capacitance and resistance of the three-phase contents. The phase fractions are determined by relating these electrical properties with the phase angles associated with the interface between water, oil, and gas phases of the mixture. To calculate the flow rate, measured capacitances from two sets of electrodes with known separation distance are cross-correlated to determine time delay. Calculated and measured results demonstrated close agreement. The percentage error exhibited by the proposed inclined capacitive plate technique is calculated and compared with published values.
引用
收藏
页码:1213 / 1218
页数:6
相关论文
共 50 条
  • [1] A Capacitance-based System Design for Measurement of Crude Oil Moisture
    Shi, Zhixue
    Zhao, Xudong
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2024, 15 (05) : 411 - 419
  • [2] ECT imaging of three-phase fluidized bed based on three-phase capacitance model
    Warsito, W
    Fan, LS
    CHEMICAL ENGINEERING SCIENCE, 2003, 58 (3-6) : 823 - 832
  • [3] Capacitance-based tomographic flow imaging system
    UMIST, United Kingdom
    Electron Lett, 1988, 7 (418-419):
  • [4] Oil-gas-water Three-phase Flow Monitoring Based on Image Fusion of ECT and ERT
    Zhang Lifeng
    MECHANICAL ENGINEERING, MATERIALS AND ENERGY III, 2014, 483 : 397 - 400
  • [5] Crude-Oil Flow Modelling in Pipeline Conditions
    Benziane, Madjid Meriem
    Liazid, Abdelkrim
    INTEGRITY OF PIPELINES TRANSPORTING HYDROCARBONS: CORROSION, MECHANISMS, CONTROL, AND MANAGEMENT, 2010, : 275 - +
  • [6] Factors influencing capacitance-based monitoring of microbial growth
    Noble, PA
    Dziuba, M
    Harrison, DJ
    Albritton, WL
    JOURNAL OF MICROBIOLOGICAL METHODS, 1999, 37 (01) : 51 - 64
  • [7] NEW INHIBITOR MONITORING TECHNIQUE FOR CRUDE-OIL PIPELINES
    HORVATH, RJ
    MATERIALS PROTECTION AND PERFORMANCE, 1973, 12 (08): : 14 - 17
  • [8] CAPACITANCE-BASED TOMOGRAPHIC FLOW IMAGING-SYSTEM
    HUANG, SM
    PLASKOWSKI, AB
    XIE, CG
    BECK, MS
    ELECTRONICS LETTERS, 1988, 24 (07) : 418 - 419
  • [9] PIPELINE FLOW BEHAVIOR OF HEAVY CRUDE-OIL EMULSIONS
    WYSLOUZIL, BE
    KESSICK, MA
    MASLIYAH, JH
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1987, 65 (03): : 353 - 360
  • [10] Laboratory simulation of capacitance-based layer-by-layer monitoring of three-dimensional printing
    Chung, D. D. L.