Electrochemical response of ascorbic and uric acids at organoclay film modified glassy carbon electrodes and sensing applications

被引:36
作者
Mbouguen, Justin Claude Kemmegne [1 ]
Kenfack, Ignas Tonle [1 ,2 ]
Walcarius, Alain [3 ]
Ngameni, Emmanuel [1 ]
机构
[1] Univ Yaounde I, Chim Analyt Lab, Fac Sci, Yaounde, Cameroon
[2] Univ Dschang, Lab Chim Minerale, Fac Sci, Dschang, Cameroon
[3] Nancy Univ, CNRS, UMR 7564, Lab Chim Phys & Microbiol Environm, F-54600 Villers Les Nancy, France
关键词
Organoclay; Clay-modified electrode; Ascorbic acid; Uric acid; Electrocatalysis; CLAY-MODIFIED ELECTRODES; ELECTROCATALYTIC OXIDATION; PASTE ELECTRODE; AMPEROMETRIC DETECTION; VOLTAMMETRIC DETECTION; HYDROGEN-PEROXIDE; DOPAMINE; SENSORS; ELECTROREDUCTION; PRECONCENTRATION;
D O I
10.1016/j.talanta.2011.04.064
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A naturally occurring Cameroonian smectite clay has been grafted with trimethylpropylammonium groups and the resulting organoclay deposited as thin film onto a glassy carbon electrode (GCE) surface. It was then exploited as a suitable matrix for the accumulation and the electrochemical detection of ascorbic acid (M) and uric acid (UA). Cyclic voltammetry revealed an increase in oxidation peak responses along with a negative shift of the corresponding anodic peak potential for both M and UA species when using the organoclay coated GCE in comparison with the bare electrode. The electroanalytical response was improved by coating the electrode surface with a first layer of sublimed ferrocene (FCs), and then overcoating with the organoclay film to avoid the mediator leaching. The resulting bilayer film exhibited good characteristics such as extended linear range and high sensitivities for AA and UA, in cyclic voltammetry and amperometry. Interestingly, the redox mediator FCs was likely to lower overpotentials for AA oxidation (but not for UA), making possible the selective detection of these species in a mixture. The developed method could be used for the determination of AA in a pharmaceutical preparation and for UA in urine. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:754 / 762
页数:9
相关论文
共 50 条
  • [41] Simultaneous Electrochemical Determination of Ascorbic Acid, Dopamine, and Uric Acid in a Variety of Food, Pharmaceutical, and Biologic Samples Using a Modified Glassy Carbon Electrode with Sunset Yellow
    Ghanbari, Hanieh
    Chamjangali, Mansour Arab
    Faraji, Mohammad
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2022, 9 (04): : 411 - 429
  • [42] Carbon-nanotube-modified glassy carbon electrode for simultaneous determination of dopamine, ascorbic acid and uric acid: The effect of functional groups
    Bi, Huaqing
    Li, Yanhui
    Liu, Shufeng
    Guo, Peizhi
    Wei, Zhongbin
    Lv, Chunxiao
    Zhang, Jizhen
    Zhao, X. S.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 1132 - 1140
  • [43] Electrochemical methods for simultaneous determination of dopamine and ascorbic acid using cetylpyridine bromide/chitosan composite film-modified glassy carbon electrode
    Cao, Xiaomei
    Luo, Liqiang
    Ding, Yaping
    Zou, Xuelian
    Bian, Ruixiang
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 129 (02) : 941 - 946
  • [44] Electrochemical characterisation of poly(3,4-ethylenedioxythiophene) film modified glassy carbon electrodes prepared in deep eutectic solvents for simultaneous sensing of biomarkers
    Prathish, Krishna P.
    Carvalho, Ricardo C.
    Brett, Christopher M. A.
    ELECTROCHIMICA ACTA, 2016, 187 : 704 - 713
  • [45] SELECTIVE ELECTROCHEMICAL DETERMINATION OF DOPAMINE AT p-NITROANILINE FILM-HOLE MODIFIED GLASSY CARBON ELECTRODES
    Olana, Bikila Nagasa
    Kitte, Shimeles Addisu
    Geletu, Abiyot Kelecha
    Soreta, Tesfaye Refera
    BULLETIN OF THE CHEMICAL SOCIETY OF ETHIOPIA, 2017, 31 (03) : 361 - 372
  • [46] Electrochemical Oxidation of Ascorbic Acid Using MgB2-MWCNT Modified Glassy Carbon Electrode
    Banan, D.
    Tan, W. T.
    Sulaiman, Y.
    Yusri, M. F.
    Zidan, M.
    Ab Ghani, S.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (12): : 12519 - 12530
  • [47] Electrochemical Oxidation and Detection of Morphine at Ordered Mesoporous Carbon Modified Glassy Carbon Electrodes
    Bo, Xiangjie
    Xie, Wenlin
    Ndamanisha, Jean Chrysostome
    Bai, Jing
    Guo, Liping
    ELECTROANALYSIS, 2009, 21 (23) : 2549 - 2555
  • [48] Electrochemical Determination of Dopamine with Ruthenium(III)-Modified Glassy Carbon and Screen-Printed Electrodes
    Redzic, Safeta
    Kahrovic, Emira
    Zahirovic, Adnan
    Turkusic, Emir
    ANALYTICAL LETTERS, 2017, 50 (10) : 1602 - 1619
  • [49] A glassy carbon electrode modified with graphene and poly(acridine red) for sensing uric acid
    Li, Yang
    Ran, Gu
    Yi, Wen Jiao
    Luo, Hong Qun
    Li, Nian Bing
    MICROCHIMICA ACTA, 2012, 178 (1-2) : 115 - 121
  • [50] Electrocatalytic oxidation and determination of norepinephrine in the presence of ascorbic and uric acids at a poly (Evans Blue)—modified glassy carbon electrode
    Liqing Lin
    Hong Yao
    Liying Huang
    Xinhua Lin
    Journal of Analytical Chemistry, 2009, 64 : 189 - 194