Electrochemical response of ascorbic and uric acids at organoclay film modified glassy carbon electrodes and sensing applications

被引:36
作者
Mbouguen, Justin Claude Kemmegne [1 ]
Kenfack, Ignas Tonle [1 ,2 ]
Walcarius, Alain [3 ]
Ngameni, Emmanuel [1 ]
机构
[1] Univ Yaounde I, Chim Analyt Lab, Fac Sci, Yaounde, Cameroon
[2] Univ Dschang, Lab Chim Minerale, Fac Sci, Dschang, Cameroon
[3] Nancy Univ, CNRS, UMR 7564, Lab Chim Phys & Microbiol Environm, F-54600 Villers Les Nancy, France
关键词
Organoclay; Clay-modified electrode; Ascorbic acid; Uric acid; Electrocatalysis; CLAY-MODIFIED ELECTRODES; ELECTROCATALYTIC OXIDATION; PASTE ELECTRODE; AMPEROMETRIC DETECTION; VOLTAMMETRIC DETECTION; HYDROGEN-PEROXIDE; DOPAMINE; SENSORS; ELECTROREDUCTION; PRECONCENTRATION;
D O I
10.1016/j.talanta.2011.04.064
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A naturally occurring Cameroonian smectite clay has been grafted with trimethylpropylammonium groups and the resulting organoclay deposited as thin film onto a glassy carbon electrode (GCE) surface. It was then exploited as a suitable matrix for the accumulation and the electrochemical detection of ascorbic acid (M) and uric acid (UA). Cyclic voltammetry revealed an increase in oxidation peak responses along with a negative shift of the corresponding anodic peak potential for both M and UA species when using the organoclay coated GCE in comparison with the bare electrode. The electroanalytical response was improved by coating the electrode surface with a first layer of sublimed ferrocene (FCs), and then overcoating with the organoclay film to avoid the mediator leaching. The resulting bilayer film exhibited good characteristics such as extended linear range and high sensitivities for AA and UA, in cyclic voltammetry and amperometry. Interestingly, the redox mediator FCs was likely to lower overpotentials for AA oxidation (but not for UA), making possible the selective detection of these species in a mixture. The developed method could be used for the determination of AA in a pharmaceutical preparation and for UA in urine. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:754 / 762
页数:9
相关论文
共 50 条
  • [31] Sensitive Electrochemical Detection of Dopamine, Uric and Ascorbic Acids Based on poly-(Dianix Yellow) Film Modified Electrode
    Karimi, Mohammad Ali
    Hatefi-Mehrjardi, Abdolhamid
    Soleymanzadeh, Mahdiyeh
    Barani, Azam
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (08): : 7089 - 7102
  • [32] Highly selective determination of uric acid in the presence of ascorbic acid at glassy carbon electrodes modified with carbon nanotubes dispersed in polylysine
    Rodriguez, Marcela C.
    Sandoval, Jose
    Galicia, Laura
    Gutierrez, Silvia
    Rivas, Gustavo A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (02) : 559 - 565
  • [33] Selective Determination of Dopamine, Ascorbic Acid and Uric Acid at SDS-MWCNTs Modified Glassy Carbon Electrode
    Zhang, Jian
    Zhu, Zhixin
    Zhu, Jianling
    Li, Kechang
    Hua, Shucheng
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (03): : 1264 - 1272
  • [34] Simultaneous determination of doparnine, ascorbic acid and uric acid at poly (Evans Blue) modified glassy carbon electrode
    Lin, Liqing
    Chen, Jinghua
    Yao, Hong
    Chen, Yuanzhong
    Zheng, Yanjie
    Lin, Xinhua
    BIOELECTROCHEMISTRY, 2008, 73 (01) : 11 - 17
  • [35] Simultaneous electrochemical determination of norepinephrine, ascorbic acid and uric acid using a graphene modified glassy carbon electrode
    Xinying Ma
    Mingyong Chao
    Meifeng Chen
    Russian Journal of Electrochemistry, 2014, 50 : 154 - 161
  • [36] Simultaneous electrochemical determination of norepinephrine, ascorbic acid and uric acid using a graphene modified glassy carbon electrode
    Ma, Xinying
    Chao, Mingyong
    Chen, Meifeng
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2014, 50 (02) : 154 - 161
  • [37] Simultaneous determination of ascorbic acid, dopamine and uric acid using poly(4-aminobutyric acid) modified glassy carbon electrode
    Zheng, Xinyu
    Zhou, Xuechou
    Ji, Xiaoyan
    Lin, Ruiyu
    Lin, Wenxiong
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 : 359 - 365
  • [38] Solar graphene modified glassy carbon electrode for the voltammetric resolution and detection of dopamine, ascorbic acid and uric acid
    Nancy, T. E. Mary
    Anithakumary, V.
    Swamy, B. E. Kumara
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 720 : 107 - 114
  • [39] Electrochemical Oxidation of Epinephrine and Uric Acid at a Layered Double Hydroxide Film Modified Glassy Carbon Electrode and Its Application
    Ni, Fang
    Wang, Yinling
    Zhang, Dandan
    Gao, Feng
    Li, Maoguo
    ELECTROANALYSIS, 2010, 22 (10) : 1130 - 1135
  • [40] Simultaneously electrochemical detection of uric acid and ascorbic acid using glassy carbon electrode modified with chrysanthemum-like titanium nitride
    Zhang, Liqin
    Feng, Jiao
    Chou, Kuo-Chih
    Su, Lei
    Hou, Xinmei
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 803 : 11 - 18