Electrochemical response of ascorbic and uric acids at organoclay film modified glassy carbon electrodes and sensing applications

被引:36
作者
Mbouguen, Justin Claude Kemmegne [1 ]
Kenfack, Ignas Tonle [1 ,2 ]
Walcarius, Alain [3 ]
Ngameni, Emmanuel [1 ]
机构
[1] Univ Yaounde I, Chim Analyt Lab, Fac Sci, Yaounde, Cameroon
[2] Univ Dschang, Lab Chim Minerale, Fac Sci, Dschang, Cameroon
[3] Nancy Univ, CNRS, UMR 7564, Lab Chim Phys & Microbiol Environm, F-54600 Villers Les Nancy, France
关键词
Organoclay; Clay-modified electrode; Ascorbic acid; Uric acid; Electrocatalysis; CLAY-MODIFIED ELECTRODES; ELECTROCATALYTIC OXIDATION; PASTE ELECTRODE; AMPEROMETRIC DETECTION; VOLTAMMETRIC DETECTION; HYDROGEN-PEROXIDE; DOPAMINE; SENSORS; ELECTROREDUCTION; PRECONCENTRATION;
D O I
10.1016/j.talanta.2011.04.064
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A naturally occurring Cameroonian smectite clay has been grafted with trimethylpropylammonium groups and the resulting organoclay deposited as thin film onto a glassy carbon electrode (GCE) surface. It was then exploited as a suitable matrix for the accumulation and the electrochemical detection of ascorbic acid (M) and uric acid (UA). Cyclic voltammetry revealed an increase in oxidation peak responses along with a negative shift of the corresponding anodic peak potential for both M and UA species when using the organoclay coated GCE in comparison with the bare electrode. The electroanalytical response was improved by coating the electrode surface with a first layer of sublimed ferrocene (FCs), and then overcoating with the organoclay film to avoid the mediator leaching. The resulting bilayer film exhibited good characteristics such as extended linear range and high sensitivities for AA and UA, in cyclic voltammetry and amperometry. Interestingly, the redox mediator FCs was likely to lower overpotentials for AA oxidation (but not for UA), making possible the selective detection of these species in a mixture. The developed method could be used for the determination of AA in a pharmaceutical preparation and for UA in urine. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:754 / 762
页数:9
相关论文
共 50 条
  • [21] A Silver Hexacyanoferrate-Graphene Modified Glassy Carbon Electrode in Electrochemical Sensing of Uric Acid and Dopamine
    Zhang, Fenghua
    Li, Sue
    Zhang, Hua
    Li, Huaixiang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (12): : 11181 - 11194
  • [22] Simultaneous determination of ascorbic acid, adrenaline and uric acid at a hematoxylin multi-wall carbon nanotube modified glassy carbon electrode
    Zare, Hamid R.
    Nasirizadeh, Navid
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 143 (02): : 666 - 672
  • [23] Electrochemical sensing of L-ascorbic acid by using a glassy carbon electrode modified with a molybdophosphate film
    Liu, Shuping
    Jiang, Xingxing
    Yang, Minghui
    MICROCHIMICA ACTA, 2019, 186 (07)
  • [24] An electrochemical response of polyelectrolyte multilayer film-coated electrodes to uric acid and ascorbic acid
    Noguchi, T
    Hoshi, TL
    Anzai, J
    SENSOR LETTERS, 2005, 3 (02) : 164 - 167
  • [25] Electrochemical oxidation and determination of ceftriaxone on a glassy carbon and carbon-nanotube-modified glassy carbon electrodes
    Majdi, S.
    Jabbari, A.
    Heli, H.
    Yadegari, H.
    Moosavi-Movahedi, A. A.
    Haghgoo, S.
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2009, 13 (03) : 407 - 416
  • [26] Graphitized mesoporous carbon modified glassy carbon electrode for selective sensing of xanthine, hypoxanthine and uric acid
    Thangaraj, Rajendiran
    Kumar, Annamalai Senthil
    ANALYTICAL METHODS, 2012, 4 (07) : 2162 - 2171
  • [27] A selective sensor based on a glassy carbon electrode modified with carbon nanotubes and ruthenium oxide/hexacyanoferrate film for simultaneous determination of ascorbic acid, epinephrine and uric acid
    Raoof, Jahan Bakhsh
    Ojani, Reza
    Baghayeri, Mehdi
    ANALYTICAL METHODS, 2011, 3 (10) : 2367 - 2373
  • [28] Electrochemical studies of ascorbic acid, dopamine, and uric acid at a DL-norvaline-deposited glassy carbon electrode
    Kamel, Mahmoud Mohamed
    Abdalla, Ehab Mahmoud
    Ibrahim, Mohamed Sayed
    Temerk, Yassin Mohamed
    CANADIAN JOURNAL OF CHEMISTRY, 2014, 92 (04) : 329 - 336
  • [29] Simultaneous electrochemical detection of uric acid and ascorbic acid at a silver doped poly(glutamic acid) modified glassy carbon electrode
    Sun, D. M.
    Hu, W. N.
    Ma, W.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (03) : 310 - 316
  • [30] Simultaneous electrochemical sensing of ascorbic acid, dopamine and uric acid at anodized nanocrystalline graphite-like pyrolytic carbon film electrode
    Hadi, Mojtaba
    Rouhollahi, Ahmad
    ANALYTICA CHIMICA ACTA, 2012, 721 : 55 - 60