Electrochemical response of ascorbic and uric acids at organoclay film modified glassy carbon electrodes and sensing applications

被引:36
作者
Mbouguen, Justin Claude Kemmegne [1 ]
Kenfack, Ignas Tonle [1 ,2 ]
Walcarius, Alain [3 ]
Ngameni, Emmanuel [1 ]
机构
[1] Univ Yaounde I, Chim Analyt Lab, Fac Sci, Yaounde, Cameroon
[2] Univ Dschang, Lab Chim Minerale, Fac Sci, Dschang, Cameroon
[3] Nancy Univ, CNRS, UMR 7564, Lab Chim Phys & Microbiol Environm, F-54600 Villers Les Nancy, France
关键词
Organoclay; Clay-modified electrode; Ascorbic acid; Uric acid; Electrocatalysis; CLAY-MODIFIED ELECTRODES; ELECTROCATALYTIC OXIDATION; PASTE ELECTRODE; AMPEROMETRIC DETECTION; VOLTAMMETRIC DETECTION; HYDROGEN-PEROXIDE; DOPAMINE; SENSORS; ELECTROREDUCTION; PRECONCENTRATION;
D O I
10.1016/j.talanta.2011.04.064
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A naturally occurring Cameroonian smectite clay has been grafted with trimethylpropylammonium groups and the resulting organoclay deposited as thin film onto a glassy carbon electrode (GCE) surface. It was then exploited as a suitable matrix for the accumulation and the electrochemical detection of ascorbic acid (M) and uric acid (UA). Cyclic voltammetry revealed an increase in oxidation peak responses along with a negative shift of the corresponding anodic peak potential for both M and UA species when using the organoclay coated GCE in comparison with the bare electrode. The electroanalytical response was improved by coating the electrode surface with a first layer of sublimed ferrocene (FCs), and then overcoating with the organoclay film to avoid the mediator leaching. The resulting bilayer film exhibited good characteristics such as extended linear range and high sensitivities for AA and UA, in cyclic voltammetry and amperometry. Interestingly, the redox mediator FCs was likely to lower overpotentials for AA oxidation (but not for UA), making possible the selective detection of these species in a mixture. The developed method could be used for the determination of AA in a pharmaceutical preparation and for UA in urine. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:754 / 762
页数:9
相关论文
共 50 条
  • [1] Electrochemical Sensor for Ascorbic Acid, Acetaminophen and Nitrite Based on Organoclay/Zr-MOF Film Modified Glassy Carbon Electrode
    Ngwem, Marcelline Carine Ngo
    Kemmegne-Mbouguen, Justin Claude
    Langmi, Henrietta W.
    Musyoka, Nicholas M.
    Mokaya, Robert
    CHEMISTRYSELECT, 2022, 7 (40):
  • [2] A Comparison of the Electrochemical and Electroanalytical Behavior of Ascorbic Acid, Dopamine and Uric Acid at Bare, Activated and Multi-Wall Carbon Nanotubes Modified Glassy Carbon Electrodes
    Zare, H. R.
    Nasirizadeh, N.
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2011, 8 : S55 - S66
  • [3] Electrochemical determination of ascorbic acid at p-phenylenediamine film-holes modified glassy carbon electrodes
    Olana, Bikila Nagasa
    Kitte, Shimeles Addisu
    Soreta, Tesfaye Refera
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2015, 80 (09) : 1161 - 1175
  • [4] Modified Carbon Paste Electrode for Kinetic Investigation and Simultaneous Determination of Ascorbic and Uric Acids
    Lima, Phabyanno Rodrigues
    Barbosa de Miranda, Paulo Rogerio
    de Oliveira, Adriano Bof
    Fonseca Goulart, Marilia Oliveira
    Kubota, Lauro Tatsuo
    ELECTROANALYSIS, 2009, 21 (21) : 2311 - 2320
  • [5] Electrochemical Sensing of Uric Acid Using Glassy Carbon Modified with Multiwall Carbon Nanotubes Dispersed in Polyethylenimine
    Gutierrez, Alejandro
    Lozano, Maria L.
    Galicia, Laura
    Ferreyra, Nancy F.
    Rivas, Gustavo A.
    ELECTROANALYSIS, 2014, 26 (10) : 2191 - 2196
  • [6] Simultaneous electrochemical determination of uric acid, dopamine, and ascorbic acid at single-walled carbon nanohorn modified glassy carbon electrode
    Zhu, Shuyun
    Li, Haijuan
    Niu, Wenxin
    Xu, Guobao
    BIOSENSORS & BIOELECTRONICS, 2009, 25 (04) : 940 - 943
  • [7] Electrochemical evaluation of ferrocene carboxylic acids confined on surfactant-clay modified glassy carbon electrodes:: oxidation of ascorbic acid and uric acid
    Fernández, L
    Carrero, H
    ELECTROCHIMICA ACTA, 2005, 50 (05) : 1233 - 1240
  • [8] Carbon nanohorns/poly(glycine) modified glassy carbon electrode: Preparation, characterization and simultaneous electrochemical determination of uric acid, dopamine and ascorbic acid
    Zhang, Guangli
    He, Ping
    Feng, Wanru
    Ding, Shuangshuang
    Chen, Jingchao
    Li, Lian
    He, Huichao
    Zhang, Susu
    Dong, Faqin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 760 : 24 - 31
  • [9] Simultaneous Electrochemical Sensing of Dopamine, Ascorbic Acid, and Uric Acid Using Nitrogen-Doped Graphene Sheet-Modified Glassy Carbon Electrode
    Moradpour, Hediyeh
    Beitollahi, Hadi
    C-JOURNAL OF CARBON RESEARCH, 2022, 8 (04):
  • [10] Simultaneous determination of uric acid and ascorbic acid at the film of chitosan incorporating cetylpyridine bromide modified glassy carbon electrode
    Cao, Xiaomei
    Xu, Yanhong
    Luo, Liqiang
    Ding, Yaping
    Zhang, Ying
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2010, 14 (05) : 829 - 834