Biomechanical evaluation of naviculocuneiform fixation with lag screw and locking plates

被引:7
|
作者
Kuestermann, Henry [1 ]
Ettinger, Sarah [1 ]
Yao, Daiwei [1 ]
Schwarze, Michael [2 ]
Plaass, Christian [1 ]
Stukenborg-Colsman, Christina [1 ]
Claassen, Leif [1 ]
机构
[1] Hannover Med Sch MHH, Diakovere Annastift Orthoped Dept, Anna von Borries Str 1-7, D-30625 Hannover, Germany
[2] Hannover Med Sch, Lab Biomech & Biomat, Haubergstr 3, D-30625 Hannover, Germany
关键词
Arthrodesis; Fusion; Midfoot; Pes planovalgus; Arthritis; JOINT PRESSURE CHANGES; PES CAVOVARUS MODEL; ARTHRODESIS; PLANTAR; FUSION;
D O I
10.1016/j.fas.2020.12.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: There have been no biomechanical evaluations of naviculocuneiform (NC) joint fixation. This study compared biomechanically 3 different fixation constructs for NC-1-3 joint fixation. Methods: The present study compared the three fixation constructs lag screw with locking plate for each NC joint, two crossed lag screws for each NC joint and a separate lag screw for each NC joint with bridging locking plates. NC-1-3 fixation was performed stepwise, and rotation of each joint was evaluated after the application of each lag screw or locking plate and their removal. Results: All examined fixation techniques led to a significant reduced rotation of the NC joints. For NC-1 rotation decreased from 2.8 degrees (Range 1.2-6.6 degrees) to 0.6 degrees (0.2-3.0 degrees) for lag screw and locking plate (p = 0.002) and from 5.0 degrees (1.7-9.8 degrees) to 1.0 degrees (0.1-3.6 degrees) for crossed lag screws (p = 0.002). For NC-2, locking plate constructs were better with 0.2 degrees (0.1-0.5 degrees) compared to crossed lag screw osteosynthesis with 0.9 degrees (0.2- 1.6 degrees) (p = 0.011). Conclusion: Each evaluated fixation technique led to a reduced NC joint rotation. The fixation of any NC joint had no relevant effect on the adjacent NC joints. The results might support surgeons treating NC joint disorders. (c) 2021 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:911 / 919
页数:9
相关论文
共 50 条
  • [31] Bicortical screw fixation provides superior biomechanical stability but devastating failure modes in periprosthetic femur fracture care using locking plates
    Clemens Gwinner
    Sven Märdian
    Tobias Dröge
    Martin Schulze
    Michael J. Raschke
    Richard Stange
    International Orthopaedics, 2015, 39 : 1749 - 1755
  • [32] Bicortical screw fixation provides superior biomechanical stability but devastating failure modes in periprosthetic femur fracture care using locking plates
    Gwinner, Clemens
    Maerdian, Sven
    Droege, Tobias
    Schulze, Martin
    Raschke, Michael J.
    Stange, Richard
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (09) : 1749 - 1755
  • [33] Biomechanical Comparison of Inter-fragmentary Compression Pressures : Lag Screw versus Herbert Screw for Anterior Odontoid Screw Fixation
    Park, Jin-Woo
    Kim, Kyoung-Tae
    Sung, Joo-Kyung
    Park, Seong-Hyun
    Seong, Ki-Woong
    Cho, Dae-Chul
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2017, 60 (05) : 498 - 503
  • [34] Biomechanical evaluation of strength and stiffness of 2.0 mm and 1.5 mm locking plates with various screw configurations on rabbit tibias
    Davis, Ella
    Canafax, Zoe
    Jankovich, Alexis
    Davis, Garrett
    Mullaney, L. T. C. Sara B.
    RESEARCH IN VETERINARY SCIENCE, 2025, 185
  • [35] Interfragmentary lag screw fixation in locking plate constructs increases stiffness in simple fracture patterns
    Maerdian, Sven
    Schmoelz, Werner
    Schaser, Klaus-Dieter
    Duda, Georg N.
    Heyland, Mark
    CLINICAL BIOMECHANICS, 2015, 30 (08) : 814 - 819
  • [36] Triple arthrodesis: A biomechanical evaluation of screw versus staple fixation
    Meyer, MS
    Alvarez, BE
    Njus, GO
    Bennett, GL
    FOOT & ANKLE INTERNATIONAL, 1996, 17 (12) : 764 - 767
  • [37] Biomechanical evaluation of occipitocervical instrumentation: screw compared with wire fixation
    Hurlbert, RJ
    Crawford, NR
    Choi, WG
    Dickman, CA
    JOURNAL OF NEUROSURGERY, 1999, 90 (01) : 84 - 90
  • [38] Biomechanical evaluation of bone screw fixation with a novel bone cement
    Tiina Juvonen
    Juha-Pekka Nuutinen
    Arto P Koistinen
    Heikki Kröger
    Reijo Lappalainen
    BioMedical Engineering OnLine, 14
  • [39] Biomechanical evaluation of bone screw fixation with a novel bone cement
    Juvonen, Tiina
    Nuutinen, Juha-Pekka
    Koistinen, Arto P.
    Kroger, Heikki
    Lappalainen, Reijo
    BIOMEDICAL ENGINEERING ONLINE, 2015, 14
  • [40] Biomechanical evaluation of posterior screw fixation in cadaveric cervical spines
    Papagelopoulos, PJ
    Currier, BL
    Neale, PG
    Hokari, Y
    Berglund, LJ
    Larson, DR
    Fisher, DR
    An, KN
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (411) : 13 - 24