Electrochemical determination of zearalenone using a label-free competitive aptasensor

被引:37
|
作者
Azri, Farah Asilah [1 ]
Eissa, Shimaa [2 ]
Zourob, Mohammed [2 ]
Chinnappan, Raja [2 ]
Sukor, Rashidah [1 ,3 ]
Yusof, Nor Azah [4 ]
Raston, Nurul Hanun Ahmad [5 ]
Alhoshani, Ali [6 ]
Jinap, Selamat [1 ,3 ]
机构
[1] Univ Putra Malaysia, Inst Trop Agr & Food Secur, Food Safety & Food Integr, Upm Serdang 43400, Selangor, Malaysia
[2] Alfaisal Univ, Dept Chem, Al Zahrawi St, Riyadh 11533, Saudi Arabia
[3] Univ Putra Malaysia, Fac Food Sci & Technol, Dept Food Sci, Upm Serdang 43400, Selangor, Malaysia
[4] Univ Putra Malaysia, Fac Sci, Dept Chem, Upm Serdang 43400, Selangor, Malaysia
[5] Univ Kebangsaan Malaysia, Fac Sci & Technol, Sch Biosci & Biotechnol, Bangi 43600, Selangor, Malaysia
[6] King Saud Univ, Coll Pharm, Dept Pharmacol & Toxicol, Riyadh 11533, Saudi Arabia
关键词
Biosensor; Zearalenone; Aptamer; Square wave voltammetry; Electrochemical impedance spectroscopy; ANTIBODY IMMOBILIZATION; MYCOTOXIN ZEARALENONE; SSDNA APTAMERS; IMMUNOSENSOR; ASSAY; SELEX; AMPLIFICATION; NANOPARTICLES; SELECTION; BIOASSAY;
D O I
10.1007/s00604-020-4218-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical aptasensor is described for determination of the phytohormone of zearalenone (ZEA). The gold electrode was modified with ZEA via covalent attachment using cysteamine-hydrochloride and 1,4-phenylene diisocyanate linker. A truncated ZEA aptamer with a dissociation constant of 13.4 +/- 2.1 nM was used in an aptasensor. The electrochemical property was investigated using square wave voltammetry for monitoring the change in the electron transfer using the ferro/ferricyanide system as redox probe. Under optimal experimental conditions, the response was best measured at a potential of 0.20 V (vs. Ag/AgCl). The signals depended on the competitive mechanism between the immobilised ZEA and free ZEA for the aptamer binding site. The aptasensor works in the range 0.01 to 1000 ng center dot mL(-1) ZEA concentration, with a detection limit of 0.017 ng center dot mL(-1). High degree of cross-reactivity with the other analogues of ZEA was observed, whereas none towards other mycotoxins. The aptasensor was further applied for the determination of ZEA in the extract of maize grain and showed good recovery percentages between 87 and 110%.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] A novel label-free electrochemical aptasensor based on graphene-polyaniline composite film for dopamine determination
    Liu, Su
    Xing, Xianrong
    Yu, Jinghua
    Lian, Wenjing
    Li, Jie
    Cui, Min
    Huang, Jiadong
    BIOSENSORS & BIOELECTRONICS, 2012, 36 (01) : 186 - 191
  • [22] Label-Free and Sensitive Determination of Cadmium Ions Using a Ti-Modified Co3O4-Based Electrochemical Aptasensor
    Liu, Yang
    Zhang, Dongwei
    Ding, Jina
    Hayat, Kashif
    Yang, Xijia
    Zhan, Xuejia
    Zhang, Dan
    Lu, Yitong
    Zhou, Pei
    BIOSENSORS-BASEL, 2020, 10 (12):
  • [23] Simultaneous and rapid determination of malachite green and leucomalachite green by a label-free colorimetric aptasensor
    Wu Wenwei
    Yi, Wang
    Liu Kexin
    Li Tiansong
    Yang Yongjie
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2020, 38 (11) : 1332 - 1339
  • [24] A label-free impedimetric aptasensor for the detection of Bacillus anthracis spore simulant
    Mazzaracchio, Vincenzo
    Neagu, Daniela
    Porchetta, Alessandro
    Marcoccio, Eleonora
    Pomponi, Alice
    Faggioni, Giovanni
    D'Amore, Nino
    Notargiacomo, Andrea
    Pea, MarialLilia
    Moscone, Danila
    Palleschi, Giuseppe
    Lista, Florigio
    Arduini, Fabiana
    BIOSENSORS & BIOELECTRONICS, 2019, 126 : 640 - 646
  • [25] A Label-Free Colorimetric Aptasensor for Flavokavain B Detection
    Ke, Sisi
    Wang, Ningrui
    Chen, Xingyu
    Tian, Jiangwei
    Li, Jiwei
    Yu, Boyang
    SENSORS, 2025, 25 (02)
  • [26] Label-free aptasensor for thrombin determination based on the nanostructured phenazine mediator
    Evtugyn, Gennady A.
    Kostyleva, Veronika B.
    Porfireva, Anna V.
    Savelieva, Maria A.
    Evtugyn, Vladimir G.
    Sitdikov, Rusal R.
    Stoikov, Ivan I.
    Antipin, Igor S.
    Hianik, Tibor
    TALANTA, 2012, 102 : 156 - 163
  • [27] Label-free fluorescent aptasensor based on exonuclease I for the determination of ochratoxin A
    Luan, Tian
    Yang, Huan-Huan
    Niu, Meng-Yu
    Zhao, Yin-He
    Chen, Shou-Shan
    Lv, Lei
    Li, Xuan-Jun
    Guo, Zhi-Jun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 50 (09)
  • [28] Determination of minimal sequence for zearalenone aptamer by computational docking and application on an indirect competitive electrochemical aptasensor
    Azri, Farah Asilah
    Selamat, Jinap
    Sukor, Rashidah
    Yusof, Nor Azah
    Raston, Nurul Hanun Ahmad
    Eissa, Shimaa
    Zourob, Mohammed
    Chinnappan, Raja
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (15) : 3861 - 3872
  • [29] An electrochemical PAH-modified aptasensor for the label-free and highly-sensitive detection of saxitoxin
    Noureen, Beenish
    Ullah, Najeeb
    Tian, Yulan
    Du, Liping
    Chen, Wei
    Wu, Chunsheng
    Wang, Ping
    TALANTA, 2022, 240
  • [30] Porphyrin functionalized graphene nanosheets-based electrochemical aptasensor for label-free ATP detection
    Zhang, Hongfen
    Han, Yujie
    Guo, Yujing
    Dong, Chuan
    JOURNAL OF MATERIALS CHEMISTRY, 2012, 22 (45) : 23900 - 23905