Utility of VITEK system for bacterial identification and antimicrobial susceptibility testing

被引:0
|
作者
Vargas, LJ
Vila, A
Lanza, A
Bonvehi, P
Nazar, J
Mikietuk, A
Labat, R
Smayevsky, J
机构
[1] Ctr Educ Med & Invest Clin Norberto Quirno, Secc Infectol, CEMIC, RA-1431 Buenos Aires, DF, Argentina
[2] Lab bioMerieux, RA-1428 Buenos Aires, DF, Argentina
来源
ACTA BIOQUIMICA CLINICA LATINOAMERICANA | 2005年 / 39卷 / 01期
关键词
VITEK; identification; antimicrobial susceptibility;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The identification (ID) and antimicrobial susceptibility testing (AST) of clinically significant bacteria provide essential information for the effective management of patients with infectious diseases. In the present study 212 isolates from hospitalized patients were tested by VITEK and traditional overnight methods in order to determine the accuracy of automated VITEK for ID and AST The type and number of isolates tested were: 94 Enterobacteriaceae isolates, 67 non-glucose-fermenting-gram-negative-rods, 29 coagulase-negative-staphylococci, 22 Enterococcus spp. and 21 S. aureus (for AST only). The 98.1 % of the isolates was correctly identified at genera and species level and the concordance in AST was 99.5%. The turnaround time (TAT) for the reporting AST results was 7.8 h using VITEK and 24 h for Kirby Bauer Change in the antimicrobial therapy using VITEK susceptibility results could have been made 16 hs sooner than using conventional methods, in 46% of the patients evaluated. The conclusion is that the inclusion of rapid methods for bacterial identification and susceptibility tests might improve the management of infected patients.
引用
收藏
页码:19 / 25
页数:7
相关论文
共 50 条
  • [1] Evaluation of the Vitek 2 system for identification and antimicrobial susceptibility testing of Staphylococcus spp.
    Nonhoff, C
    Rottiers, S
    Struelens, MJ
    CLINICAL MICROBIOLOGY AND INFECTION, 2005, 11 (02) : 150 - 153
  • [2] Evaluation of the Automated System Vitek2 for Identification and Antimicrobial Susceptibility Testing of Brazilian Gram-Positive Cocci Strains
    d'Azevedo, Pedro Alves
    Siquiera, Itacy
    Gugel, Juliana
    Souza Antunes, Ana Lucia
    Secchi, Carina
    Pasternak, Jacyr
    Martino, Marines Dalla Vale
    BRAZILIAN JOURNAL OF INFECTIOUS DISEASES, 2009, 13 (02) : 107 - 110
  • [3] Effect of antimicrobial stewardship with rapid MALDI-TOF identification and Vitek 2 antimicrobial susceptibility testing on hospitalization outcome
    Cavalieri, Stephen J.
    Kwon, Seunghyug
    Vivekanandan, Renuga
    Ased, Sumaya
    Carroll, Cassara
    Anthone, Jennifer
    Schmidt, David
    Baysden, Maddy
    Destache, Christopher J.
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2019, 95 (02) : 208 - 211
  • [4] Performance Evaluation of VITEK 2 System in Meropenem Susceptibility Testing of Clinical Pseudomonas aeruginosa Isolates
    Acuner, Ibrahim Cagatay
    Bayramoglu, Gulcin
    Birinci, Asuman
    Cihan, Cigdem Cekic
    Bek, Yuksel
    Durupinar, Belma
    MIKROBIYOLOJI BULTENI, 2011, 45 (03): : 411 - 421
  • [5] Comparison of Vitek identification and antifungal susceptibility testing methods to DNA sequencing and Sensititre YeastOne antifungal testing
    Vijgen, Sara
    Nys, Sita
    Naesens, Reinout
    Magerman, Koen
    Boel, An
    Cartuyvels, Reinoud
    MEDICAL MYCOLOGY, 2011, 49 (01) : 107 - 110
  • [6] THE EVALUATION OF ANTIMICROBIAL SUSCEPTIBILITY OF URINE ENTEROCOCCI WITH THE VITEK 2 AUTOMATED SYSTEM IN EASTERN TURKEY
    Sibel, A. K.
    Koroglu, Mehmet
    Muharrem, A. K.
    SOUTHEAST ASIAN JOURNAL OF TROPICAL MEDICINE AND PUBLIC HEALTH, 2012, 43 (04) : 986 - 991
  • [7] Rapid identification and antimicrobial susceptibility profiling of Gram-positive cocci in blood cultures with the Vitek 2 system
    A. Lupetti
    S. Barnini
    B. Castagna
    A.-L. Capria
    P. H. Nibbering
    European Journal of Clinical Microbiology & Infectious Diseases, 2010, 29 : 89 - 95
  • [8] Evaluation of the VITEK 2 cards for identification and antimicrobial susceptibility testing of non-glucose-fermenting Gram-negative bacilli
    Hsieh, Wen-Shyang
    Sung, Ling-Ling
    Tsai, Kun-Chou
    Ho, Hsin-Tsung
    APMIS, 2009, 117 (04) : 241 - 247
  • [9] Comparison of workflow and accuracy of identification and antimicrobial susceptibility testing of clinical isolates of Enterobacteriaceae, Pseudomonas aeruginosa and enterococci by Vitek 2 and routine methods
    Rantakokko-Jalava, K
    Elo-Lehtonen, E
    Meurman, O
    APMIS, 2006, 114 (01) : 43 - 49
  • [10] Susceptibility testing of pseudomonas aeruginosa by the Vitek 2 system: A comparison with Etest results
    Saegeman, V
    Huynen, P
    Colaert, J
    Melin, P
    Verhaegen, J
    ACTA CLINICA BELGICA, 2005, 60 (01): : 3 - 9