Evidence for reliability, validity and responsiveness of Turkish Foot and Ankle Ability Measure (FAAM)

被引:22
|
作者
Celik, Derya [1 ]
Malkoc, Melih [2 ]
Martin, RobRoy [3 ]
机构
[1] Istanbul Univ, Div Physiotherapy & Rehabil, Fac Hlth Sci, TR-34740 Istanbul, Turkey
[2] Medipol Univ, Dept Orthoped & Traumatol, Istanbul, Turkey
[3] Duquesne Univ, Pittsburgh, PA 15219 USA
关键词
Cross-cultural adaptation; Ankle and foot; Outcome measurement; Psychometric properties; VERSION; VALIDATION; TRANSLATION; PAIN;
D O I
10.1007/s00296-016-3485-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To translate and culturally adapt the Foot and Ankle Ability Measure (FAAM) into Turkish and assess the psychometric properties of the translated version. The FAAM was translated into Turkish according to Beaton's recommendations and it is called FAAM-T. Ninety-eight patients (39 males, mean +/- SD age 35.0 +/- 14.0 years; range 16-71 years) with different foot and ankle complaints were included, and the score was completed twice by each participant after 7 days of the first assessment to assess test-retest reliability based on the inter-rater correlation coefficient, whereas Cronbach's alpha evaluated internal consistency. External validity was evaluated with correlations between the FAAM-T, Foot Function Index (FFI) and Short Form-36 (SF-36). The distribution of floor and ceiling effects was determined. The test-retest reliability was 0.90 for both FAAM-T subscales. Cronbach's alpha coefficient was 0.95 and 0.91 for FAAM-T activity of daily living (ADL) and FAAM-T Sport subscales, respectively. The FAAM-T ADL and Sport subscales demonstrated very good correlation with the FFI (r = 0.70 and 0.63, respectively). The FAAM-T ADL and Sport subscales had a high level of association with physical functioning and the physical component scale (r = 0.71, r = 0.70 and r = 0.51, r = 0.55, respectively; P = 0.001) of the SF-36. The weakest associations were found between the FAAM-T ADL, FAAM-T Sport subscales and the SF-36 the vitality (r = 0.27, P = 0.008 and r = 0.28, P = 0.01, respectively). The study provides preliminary evidence that the FAAM-T is reliable, valid and responsive outcome measurement of patients with foot and ankle pathologies.
引用
收藏
页码:1469 / 1476
页数:8
相关论文
共 50 条
  • [11] Greek Cross-Cultural Adaptation, Reliability, and Validity of the Quick Foot and Ankle Ability Measure Questionnaire
    Koumantakis, George A.
    Galazoulas, Anastasios
    Stefanakis, Marios
    Paraskevopoulos, Eleftherios
    Gioftsos, George
    Papandreou, Maria
    JOURNAL OF SPORT REHABILITATION, 2023, 32 (08) : 855 - 862
  • [12] Reliability, validity and responsiveness of the Italian version of the Foot Function Index in patients with foot and ankle diseases
    Martinelli, Nicolo
    Scotto, Gennaro Maria
    Sartorelli, Elena
    Bonifacini, Carlo
    Bianchi, Alberto
    Malerba, Francesco
    QUALITY OF LIFE RESEARCH, 2014, 23 (01) : 277 - 284
  • [13] Validity and Reliability of Visual Analog Scale Foot and Ankle: The Turkish Version
    Gur, Gozde
    Turgut, Elif
    Dilek, Burcu
    Baltaci, Gul
    Bek, Nilgun
    Yakut, Yavuz
    JOURNAL OF FOOT & ANKLE SURGERY, 2017, 56 (06): : 1213 - 1217
  • [14] Validity and reliability of the Turkish version of the Self-reported Foot and Ankle Score in patients with foot or ankle pain
    Yazici, Gokhan
    Yazici, Melek Volkan
    Bayraktar, Deniz
    Varol, Fatmagul
    Gunduz, Arzu Guclu
    Bek, Nilgun
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2020, 54 (04) : 408 - 413
  • [15] Responsiveness of the PROMIS and FAAM Instruments in Foot and Ankle Orthopedic Population
    Hung, Man
    Baumhauer, Judith F.
    Licari, Frank W.
    Bounsanga, Jerry
    Voss, Maren W.
    Saltzman, Charles L.
    FOOT & ANKLE INTERNATIONAL, 2019, 40 (01) : 56 - 64
  • [16] Reliability, validity and responsiveness of the German self-reported foot and ankle score (SEFAS) in patients with foot or ankle surgery
    Arbab, Dariusch
    Kuhlmann, Katharina
    Schnurr, Christoph
    Bouillon, Bertil
    Luering, Christian
    Konig, Dietmar
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18
  • [17] Reliability, validity and responsiveness of the German self-reported foot and ankle score (SEFAS) in patients with foot or ankle surgery
    Dariusch Arbab
    Katharina Kuhlmann
    Christoph Schnurr
    Bertil Bouillon
    Christian Lüring
    Dietmar König
    BMC Musculoskeletal Disorders, 18
  • [18] Dual-panel translation to Danish and Rasch validation of the Foot and Ankle Ability Measure (FAAM-DK)
    Obionu, Kenneth Chukwuemeka
    Krogsgaard, Michael Rindom
    Hansen, Christian Fugl
    Comins, Jonathan David
    FOOT AND ANKLE SURGERY, 2022, 28 (05) : 588 - 594
  • [19] Validation of Foot and Ankle Ability Measure (FAAM) and the Foot and Ankle Outcome Score (FAOS) in individuals with chronic ankle instability: a cross-sectional observational study
    Goulart Neto, Antonio Manoel
    Maffulli, Nicola
    Migliorini, Filippo
    de Menezes, Fabio Sprada
    Okubo, Rodrigo
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [20] Reliability, validity and responsiveness of the German Manchester-Oxford Foot Questionnaire (MOXFQ) in patients with foot or ankle surgery
    Arbab, Dariusch
    Kuhlmann, Katharina
    Ringendahl, Hubert
    Bouillon, Bertil
    Eysel, Peer
    Koenig, Dietmar
    FOOT AND ANKLE SURGERY, 2018, 24 (06) : 481 - 485