Rapid start-up of biofilter for removal of iron and manganese from groundwater

被引:7
作者
Zeng, Huiping [1 ]
Li, Dong [2 ]
Zhang, Jie [1 ,2 ]
机构
[1] Harbin Inst Technol, State Key Lab Urban Water Resource & Environm, Harbin 150090, Peoples R China
[2] Beijing Univ Technol, Lab Water Qual Sci & Water Environm, Beijing 100022, Peoples R China
来源
ENVIRONMENT MATERIALS AND ENVIRONMENT MANAGEMENT PTS 1-3 | 2010年 / 113-116卷
关键词
groundwater; iron removal; manganese removal; biofilter; start-up procedure; MICROBIAL CONSORTIA; SAND FILTERS;
D O I
10.4028/www.scientific.net/AMR.113-116.1316
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
"aged" biofilter media was adopted as the inoculum to accelerate the maturation of biofilter for iron and manganese removal in the start-up of filter column. morphology of "aged" biofilter media and new quartz sand was observed with SEM. The results indicate that the "aged" biofilter media coated by a large quantity of bacteria which reduces the start-up time to 30 daysand affords strong Mn-removal efficiency at the beginning of the process. This method probably can be used for the start-up of new filters when there are well-established biofilters around.
引用
收藏
页码:1316 / +
页数:2
相关论文
共 14 条
[1]  
[Anonymous], STANDARD METHODS WAT
[2]  
Frischherz H., 1985, Water Supply, V3, P125
[3]  
GB, GB57492006
[4]  
GHIORSE WC, 1984, ANNU REV MICROBIOL, V38, P515, DOI 10.1146/annurev.mi.38.100184.002503
[5]  
KNOCKE WR, 1987, JAWWA, V3, P75
[6]  
MOUCHET P, 1992, J AM WATER WORKS ASS, V84, P158
[7]  
MOUCHET P, 1995, P WAT QUAL TECHN C A, P2287
[8]   Removal of iron and manganese using biological roughing up flow filtration technology [J].
Pacini, VA ;
Ingallinella, AM ;
Sanguinetti, G .
WATER RESEARCH, 2005, 39 (18) :4463-4475
[9]  
ROBINSON RB, 1987, JAWWA, V11, P64
[10]  
SEPPANEN HT, 1992, J INST WATER ENV MAN, V6, P333