The high field project at Dresden/Rossendorf:: A pulsed 100 T/10 ms laboratory at an infrared free-electron-laser facility

被引:29
作者
Herrmannsdörfer, T
Krug, H
Pobell, F
Zherlitsyn, S
Eschrig, H
Freudenberger, J
Müller, KH
Schultz, L
机构
[1] Rossendorf Inc, Forschungszentrum Rossendorf EV, D-01314 Dresden, Germany
[2] Leibniz Inst Festkorper & Werkstoffforsch, D-01171 Dresden, Germany
关键词
D O I
10.1023/A:1025680916320
中图分类号
O59 [应用物理学];
学科分类号
摘要
This article describes the project to build a pulsed magnetic field user laboratory at the Forschungszentrum Rossendorf near Dresden. Using a 50 MJ/24 kV capacitor bank, pulsed fields and rise times of 100 T/10 ms, 70 T/100 ms, and 60 T/1 s should be achieved. The laboratory will be built next to a free-electron-laser-facility for the middle and far infrared (5 to 150 mm, 2 ps, cw). We describe the work which has been performed until now to start the construction of the laboratory in 2003: coil concepts and computer simulations, materials development for the high field coils, and design of the capacitor bank modules. In addition, a pilot laboratory has been set up where fields up to 62 T/15 ms have been obtained with a 1 MJ/10 kV capacitor module. It is used to gain experience in the operation of such a facility and to test various parts of it. In this test laboratory special devices have been developed for measurements of magnetization and magnetoresistance, and have been successfully used to investigate various materials including semiconductors and Heavy Fermion compounds. In particular, metamagnetic transitions in intermetallic compounds and the irreversibility field of a high-T-c superconductor have been determined. Shubnikov-de Haas oscillations have been observed in the semimetallic compound CeBiPt. Resistance relaxation has been observed to start less than 1 second after the field pulse. It could be shown for the first time that nuclear magnetic resonance (NMR) is detectable in pulsed fields.
引用
收藏
页码:41 / 59
页数:19
相关论文
共 20 条
[1]   Supersaturated solid solution of niobium in copper by mechanical alloying [J].
Botcharova, E ;
Heilmaier, M ;
Freudenberger, J ;
Drew, G ;
Kudashow, D ;
Martin, U ;
Schultz, L .
JOURNAL OF ALLOYS AND COMPOUNDS, 2003, 351 (1-2) :119-125
[2]   Anomalous magnetic behaviour of NdCu2 in high magnetic fields [J].
Doerr, M ;
Kramp, S ;
Loewenhaupt, M ;
Rotter, M ;
Kratz, R ;
Krug, H ;
Eckert, D ;
Siegel, H ;
Verges, P .
PHYSICA B-CONDENSED MATTER, 2001, 294 :164-167
[3]   High precision pick-up coils for pulsed field magnetization measurements [J].
Eckert, D ;
Grössinger, R ;
Doerr, M ;
Fischer, F ;
Handstein, A ;
Hinz, D ;
Siegel, H ;
Verges, P ;
Müller, KH .
PHYSICA B, 2001, 294 :705-708
[4]  
Freudenberger J, 2002, ADV ENG MATER, V4, P677, DOI 10.1002/1527-2648(20020916)4:9<677::AID-ADEM677>3.0.CO
[5]  
2-I
[6]  
GABRIEL F, NUCL INSTR METHODS B, V161, P1143
[7]   THz radiation from free electron lasers and its potential for cell and tissue studies [J].
Grosse, E .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (21) :3755-3760
[8]   Pulsed field studies on the quantum nanomagnet Mn12Ac [J].
Grössinger, R ;
Caneschi, A ;
Dörr, M ;
Eckert, D ;
Fischer, F ;
Handstein, A ;
Hinz, D ;
Kratz, R ;
Krug, H ;
Müller, KH ;
Novak, MA ;
Siegel, H ;
Verges, P .
PHYSICA B, 2001, 294 :307-309
[9]   High-strength, high-nitrogen stainless steel-copper composite wires for conductors in pulsed high-field magnets [J].
Grünberger, W ;
Heilmaier, M ;
Schultz, L .
MATERIALS LETTERS, 2002, 52 (03) :154-158
[10]   High-strength pearlitic steel-copper composite wires for conductors in pulsed high-field magnets [J].
Grünberger, W ;
Heilmaier, M ;
Schultz, L .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2001, 303 (1-2) :127-133