Detection of juxta-pleural lung nodules in computed tomography images

被引:10
作者
Aresta, Guilherme [1 ,2 ]
Cunha, Antonio [2 ,3 ]
Campilho, Aurelio [1 ,2 ]
机构
[1] Univ Porto, Fac Engn, R Dr Roberto Frias, P-4200464 Oporto, Portugal
[2] INESC TEC Inst Engn Sistemas & Comp Technol & Cie, R Dr Roberto Frias, P-4200 Oporto, Portugal
[3] Univ Tras Os Montes & Alto Douro, P-5001801 Quinta De Prados, Vila Real, Portugal
来源
MEDICAL IMAGING 2017: COMPUTER-AIDED DIAGNOSIS | 2017年 / 10134卷
关键词
Computer-aided diagnosis; lung cancer; nodule detection; juxta-pleural lung nodule; PULMONARY NODULES;
D O I
10.1117/12.2252022
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A method for the detection of juxta-pleural lung nodules with radius <= 5 mm in chest computed tomography images is proposed. The lung volume is segmented using region-growing and refined with morphological operations and active contours to include juxta-pleural nodules. Nodule candidates are searched slice-wise inside the lung volume segmentation. Solid nodules are detected by selecting an appropriate threshold inside a representative sliding window. Sub-solid and non-solid nodules are enhanced with a multiscale Laplacian-of-Gaussian filtering prior to their detection. Obvious non-nodule candidates, namely small blood vessels, are discarded using fixed rules. Then, a support vector machine with radial basis function is trained with the remaining candidates to further reduce the number of false positives (FPs). The final system sensitivity is 57.4% with 4 FPs/scan. The performance is similar or better than state-of-the-art methods, especially when considering the high number and small radius of the studied juxta-pleural nodules.
引用
收藏
页数:7
相关论文
共 13 条
[1]   Lung image database consortium: Developing a resource for the medical imaging research community [J].
Armato, SG ;
McLennan, G ;
McNitt-Gray, MF ;
Meyer, CR ;
Yankelevitz, D ;
Aberle, DR ;
Henschke, CI ;
Hoffman, EA ;
Kazerooni, EA ;
MacMahon, H ;
Reeves, AP ;
Croft, BY ;
Clarke, LP .
RADIOLOGY, 2004, 232 (03) :739-748
[2]   Benefits and Harms of CT Screening for Lung Cancer A Systematic Review [J].
Bach, Peter B. ;
Mirkin, Joshua N. ;
Oliver, Thomas K. ;
Azzoli, Christopher G. ;
Berry, Donald A. ;
Brawley, Otis W. ;
Byers, Tim ;
Colditz, Graham A. ;
Gould, Michael K. ;
Jett, James R. ;
Sabichi, Anita L. ;
Smith-Bindman, Rebecca ;
Wood, Douglas E. ;
Qaseem, Amir ;
Detterbeck, Frank C. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2012, 307 (22) :2418-2429
[3]   Active contours without edges [J].
Chan, TF ;
Vese, LA .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2001, 10 (02) :266-277
[4]   Cancer survival in Europe 1999-2007 by country and age: results of EUROCARE-5-a population-based study [J].
De Angelis, Roberta ;
Sant, Milena ;
Coleman, Michel P. ;
Francisci, Silvia ;
Baili, Paolo ;
Pierannunzio, Daniela ;
Trama, Annalisa ;
Visser, Otto ;
Brenner, Hermann ;
Ardanaz, Eva ;
Bielska-Lasota, Magdalena ;
Engholm, Gerda ;
Nennecke, Alice ;
Siesling, Sabine ;
Berrino, Franco ;
Capocaccia, Riccardo .
LANCET ONCOLOGY, 2014, 15 (01) :23-34
[5]   Approaches to juxta-pleural nodule detection in CT images within the MAGIC-5 Collaboration [J].
De Nunzio, G. ;
Massafra, A. ;
Cataldo, R. ;
De Mitri, I. ;
Peccarisi, M. ;
Fantacci, M. E. ;
Gargano, G. ;
Lopez Torres, E. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 :S103-S106
[6]  
Fuchs HE., 2021, CA-CANCER J CLIN, V71, P7, DOI [10.3322/caac.21654, DOI 10.3322/caac.20073, DOI 10.3322/CAAC.21332]
[7]   Fast and Adaptive Detection of Pulmonary Nodules in Thoracic CT Images Using a Hierarchical Vector Quantization Scheme [J].
Han, Hao ;
Li, Lihong ;
Han, Fangfang ;
Song, Bowen ;
Moore, William ;
Liang, Zhengrong .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2015, 19 (02) :648-659
[8]   Reliable Lung Segmentation Methodology by Including Juxtapleural Nodules [J].
Novo, J. ;
Rouco, J. ;
Mendonca, A. ;
Campilho, Aurelio .
IMAGE ANALYSIS AND RECOGNITION, ICIAR 2014, PT II, 2014, 8815 :227-235
[9]   THRESHOLD SELECTION METHOD FROM GRAY-LEVEL HISTOGRAMS [J].
OTSU, N .
IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS, 1979, 9 (01) :62-66
[10]   Lung nodule detection in low-dose and thin-slice computed tomography [J].
Retico, A. ;
Delogu, P. ;
Fantacci, M. E. ;
Gori, I. ;
Martinez, A. Preite .
COMPUTERS IN BIOLOGY AND MEDICINE, 2008, 38 (04) :525-534