TOTAL KNEE ARTHROPLASTY WITH A MOBILE TIBIAL BEARING. MEDIUM-TERM FOLLOW-UP RESULTS

被引:1
|
作者
Betoni Guglielmetti, Luiz Gabriel [1 ]
Couto, Rodrigo do Carmo [1 ]
Arbix de Camargo, Osmar Pedro [1 ]
Severino, Nilson Roberto [1 ]
Leite Cury, Ricardo de Paula [1 ]
de Oliveira, Victor Marques [1 ]
Aihara, Tatsuo [1 ]
Avakian, Roger [1 ]
机构
[1] Fac Ciencias Med Santa Casa Sao Paulo, Dept Orthoped & Traumatol, Sao Paulo, Brazil
来源
ACTA ORTOPEDICA BRASILEIRA | 2010年 / 18卷 / 06期
关键词
Knee arthroplasty knee replacement; Knee prosthesis; Treatment outcome Outcome assessment (health care); Postoperative complications; FIXED-BEARING; ROTATING-PLATFORM; REPLACEMENT; PROSTHESIS; KINEMATICS; DESIGN; DISLOCATION; FRACTURES; OUTCOMES; SYSTEM;
D O I
10.1590/S1413-78522010000600001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective Evaluation of mid term follow up results of the application of a total knee replacement with a mobile tibial bearing design Methods Ninety six patients (107 knees) were submitted to total knee Arthroplasty performed with a model of prosthesis with rotating mobility in the tibial component The patients were evaluated after a mean follow up of 52 7 months standard deviation 21 94 (minimum 24 months and maximum 120 months) through the Knee Society Clinical Rating System (KSCRS) with a mean outcome of 78 22 points Results The complications that occurred immediately after or during the surgery included one wound dehiscence with spontaneous healing two patellar fractures one fracture of the medial condyle of the femur three peroneal nerve impairments and one sympathetic reflex nervous distrophy Subsequent complications were one patellar fracture one distal fracture of the femur four aseptic loosenings and four deep joint infections which required arthroplastic revisions Conclusion With the exception of the cases requiring arthroplastic revision due to septic or aseptic loosening the authors conclude that the clinical and functional results obtained with Total Knee Replacement with a mobile bearing component in a mid term follow up were good
引用
收藏
页码:310 / 314
页数:5
相关论文
共 50 条
  • [21] Mobile-Bearing Total Knee Arthroplasty A Meta-Analysis
    Carothers, Joshua T.
    Kim, Raymond H.
    Dennis, Douglas A.
    Southworth, Carleton
    JOURNAL OF ARTHROPLASTY, 2011, 26 (04) : 537 - 542
  • [22] Mobile bearing and fixed bearing total knee arthroplasty
    Capella, Marcello
    Dolfin, Marco
    Saccia, Francesco
    ANNALS OF TRANSLATIONAL MEDICINE, 2016, 4 (07)
  • [23] Survivorship at minimum 10-year follow-up of a rotating-platform, mobile-bearing, posterior-stabilised total knee arthroplasty
    Ulivi, Michele
    Orlandini, Luca
    Meroni, Valentina
    Consonni, Olmo
    Sansone, Valerio
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (06) : 1669 - 1675
  • [24] LCS mobile bearing total knee arthroplasty without patellar resurfacing. Does the unresurfaced patella affect outcome? Survivorship at a minimum 10-year follow-up
    O'Brien, Seamus
    Spence, David J.
    Ogonda, Luke O.
    Beverland, David E.
    KNEE, 2012, 19 (04) : 335 - 338
  • [25] Long-Term Follow-Up of Medial Pivot Total Knee Arthroplasty: A Systematic Review of the Current Evidence
    Cacciola, Giorgio
    Giustra, Fortunato
    Bosco, Francesco
    Sabatini, Luigi
    Risitano, Salvatore
    De Meo, Federico
    Braconi, Lorenzo
    Cavaliere, Pietro
    Masse, Alessandro
    Solarino, Giuseppe
    PROSTHESIS, 2023, 5 (03): : 622 - 634
  • [26] Greater Satisfaction in Older Patients With a Mobile-Bearing Compared With Fixed-Bearing Total Knee Arthroplasty
    Lizaur-Utrilla, Alejandro
    Sanz-Reig, Javier
    Angeles Trigueros-Rentero, Maria
    JOURNAL OF ARTHROPLASTY, 2012, 27 (02) : 207 - 212
  • [27] Long-Term Follow-Up of Mobile Bearing Total Ankle Arthroplasty in the United States
    Jastifer, James R.
    Coughlin, Michael J.
    FOOT & ANKLE INTERNATIONAL, 2015, 36 (02) : 143 - 150
  • [28] Rotaglide Total Knee Arthroplasty: A Long-Term Follow-up Study
    Metsovitis, Stergios R.
    Ploumis, Avraam L.
    Chantzidis, Paraskevas T.
    Terzidis, Ioannis P.
    Christodoulou, Anastasios G.
    Dimitriou, Christos G.
    Tsakonas, Athanasios C.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (09) : 878 - 884
  • [29] Medium-Term Follow-Up of a Modular Tapered Noncemented Titanium Stem in Revision Total Hip Arthroplasty A Single-Surgeon Experience
    Klauser, Wolfgang
    Bangert, Yannic
    Lubinus, Philipp
    Kendoff, Daniel
    JOURNAL OF ARTHROPLASTY, 2013, 28 (01) : 84 - 89
  • [30] Mobile- versus fixed-bearing total knee arthroplasty: a prospective randomized controlled trial featuring 6-10-year follow-up
    Baktir, Ali
    Karaaslan, Fatih
    Yurdakul, Emre
    Karaoglu, Sinan
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2016, 50 (01) : 1 - 9