TOTAL KNEE ARTHROPLASTY WITH A MOBILE TIBIAL BEARING. MEDIUM-TERM FOLLOW-UP RESULTS

被引:1
|
作者
Betoni Guglielmetti, Luiz Gabriel [1 ]
Couto, Rodrigo do Carmo [1 ]
Arbix de Camargo, Osmar Pedro [1 ]
Severino, Nilson Roberto [1 ]
Leite Cury, Ricardo de Paula [1 ]
de Oliveira, Victor Marques [1 ]
Aihara, Tatsuo [1 ]
Avakian, Roger [1 ]
机构
[1] Fac Ciencias Med Santa Casa Sao Paulo, Dept Orthoped & Traumatol, Sao Paulo, Brazil
来源
ACTA ORTOPEDICA BRASILEIRA | 2010年 / 18卷 / 06期
关键词
Knee arthroplasty knee replacement; Knee prosthesis; Treatment outcome Outcome assessment (health care); Postoperative complications; FIXED-BEARING; ROTATING-PLATFORM; REPLACEMENT; PROSTHESIS; KINEMATICS; DESIGN; DISLOCATION; FRACTURES; OUTCOMES; SYSTEM;
D O I
10.1590/S1413-78522010000600001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective Evaluation of mid term follow up results of the application of a total knee replacement with a mobile tibial bearing design Methods Ninety six patients (107 knees) were submitted to total knee Arthroplasty performed with a model of prosthesis with rotating mobility in the tibial component The patients were evaluated after a mean follow up of 52 7 months standard deviation 21 94 (minimum 24 months and maximum 120 months) through the Knee Society Clinical Rating System (KSCRS) with a mean outcome of 78 22 points Results The complications that occurred immediately after or during the surgery included one wound dehiscence with spontaneous healing two patellar fractures one fracture of the medial condyle of the femur three peroneal nerve impairments and one sympathetic reflex nervous distrophy Subsequent complications were one patellar fracture one distal fracture of the femur four aseptic loosenings and four deep joint infections which required arthroplastic revisions Conclusion With the exception of the cases requiring arthroplastic revision due to septic or aseptic loosening the authors conclude that the clinical and functional results obtained with Total Knee Replacement with a mobile bearing component in a mid term follow up were good
引用
收藏
页码:310 / 314
页数:5
相关论文
共 50 条
  • [1] Medium-term follow-up of 149 mobile-bearing total knee arthroplasties and evaluation of prognostic factors influencing outcomes
    Rosso, Federica
    Cottino, Umberto
    Olivero, Matteo
    Bonasia, Davide Edoardo
    Bruzzone, Matteo
    Rossi, Roberto
    JOURNAL OF ORTHOPAEDIC SURGERY, 2018, 26 (01):
  • [2] Will Mobile-Bearing Total Knee Arthroplasty Be Lost to History? A Comparative Study of Long-Term Follow-Up
    Kim, Sangrim
    Yang, Joseph
    Moon, Seokhwan
    Choi, Sungwook
    LIFE-BASEL, 2024, 14 (10):
  • [3] Clinical performance and survivorship of navigated floating platform mobile-bearing total knee arthroplasty: A minimum 10-year follow-up
    Kim, Sang-Min
    Seo, Jai-Gon
    Lim, Seung-Jae
    Lim, Hyung-Tae
    Cho, Chang-Ho
    Moon, Young-Wan
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2017, 13 (03)
  • [4] A comparative analysis between fixed bearing total knee arthroplasty (PFC Sigma) and rotating platform total knee arthroplasty (PFC-RP) with minimum 3-year follow-up
    Jawed, Akram
    Kumar, Vijay
    Malhotra, R.
    Yadav, C. S.
    Bhan, S.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2012, 132 (06) : 875 - 881
  • [5] Cementless Mobile-Bearing Total Knee Arthroplasty: 10 Years Follow-Up
    Abdallatif, Ahmad G.
    Winkworth, Corrina
    Aslam, Nadim
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (04)
  • [6] Comparison of fixed- and mobile-bearing total knee arthroplasty with a mean five-year follow-up: A meta-analysis
    Cheng, Mengqi
    Chen, Desheng
    Guo, Yongyuan
    Zhu, Chen
    Zhang, Xianlong
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 6 (01) : 45 - 51
  • [7] OUTCOMES OF 51 MOBILE BEARING TOTAL KNEE PROSTHESIS IN A SHORT-MEDIUM FOLLOW UP
    D'amelio, A.
    Atzori, F.
    Bersano, A.
    Gastaldo, M.
    Masse, A.
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2012, 63 (06) : 455 - 463
  • [8] EFFECTS OF MOBILE- AND FIXED-BEARING TIBIAL INSERTS ON CLINICAL RESULTS OF KNEE ARTHROPLASTY: A RETROSPECTIVE STUDY
    Cakmak, Mehmet Fevzi
    Horoz, Levent
    JOURNAL OF ISTANBUL FACULTY OF MEDICINE-ISTANBUL TIP FAKULTESI DERGISI, 2024, 87 (01): : 81 - 86
  • [9] NexGenA® LPS mobile bearing total knee arthroplasty: 10-year results
    Bistolfi, Alessandro
    Lee, Gwo-Chin
    Deledda, Davide
    Rosso, Federica
    Berchialla, Paola
    Crova, Maurizio
    Massazza, Giuseppe
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (08) : 1786 - 1792
  • [10] Medium-term clinical results of unicompartmental knee arthroplasty for the treatment for spontaneous osteonecrosis of the knee with four to 15 years of follow-up
    Fukuoka, Shinichi
    Fukunaga, Kenji
    Taniura, Kei
    Sasaki, Takeharu
    Takaoka, Kunio
    KNEE, 2019, 26 (05) : 1111 - 1116