Small-vessel radiography in situ with monochromatic synchrotron radiation

被引:135
|
作者
Mori, H
Hyodo, K
Tanaka, E
UddinMohammed, M
Yamakawa, A
Shinozaki, Y
Nakazawa, H
Tanaka, Y
Sekka, T
Iwata, Y
Handa, S
Umetani, K
Ueki, H
Yokoyama, T
Tanioka, K
Kubota, M
Hosaka, H
Ishikawa, N
Ando, M
机构
[1] TOKAI UNIV,SCH MED,DEPT SURG 2,ISEHARA,KANAGAWA 25911,JAPAN
[2] TOKAI UNIV,SCH MED,DEPT RADIOL,ISEHARA,KANAGAWA 25911,JAPAN
[3] TOKAI UNIV,SCH MED,DEPT INTERNAL MED 1,ISEHARA,KANAGAWA 25911,JAPAN
[4] NATL LAB HIGH ENERGY PHYS,TSUKUBA,IBARAKI 305,JAPAN
[5] HITACHI LTD,CENT RES LAB,TOKYO,JAPAN
[6] NIPPON HOSO KYOKAI SCI & TECH RES LABS,TOKYO,JAPAN
[7] NIHON KOHDEN,TOKYO,JAPAN
关键词
angiography; technology; cerebral angiography; coronary angiography; intestines; radiography; pancreas; synchrotron;
D O I
10.1148/radiology.201.1.8816540
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the usefulness of a radiographic system with monochromatic synchrotron radiation to depict small vessels and peripheral secretory ducts. MATERIALS AND METHODS: Radiography of various organs was tested in 14 anesthetized dogs and pancreatography was performed in an excised human pancreas by using the following system: monochromatic synchrotron radiation with an energy level just above the k absorption edge of iodine as an x-ray source and a high-definition TV system with a high-light-sensitivity image pick-up tube camera coupled with a fluorescent screen as a detector. RESULTS: This system allowed depiction of small vessels (diameter <50-100 mu m) of the heart (penetrating transmural artery), brain (perforating arteries that arise directly in the circle of Willis), and intestinal organs (vasa recta and their submucosal communications) and of small branches (down to the fifth order) of the pancreatic duct. CONCLUSION: The synchrotron radiation system may be useful for evaluating microcirculatory disorders and early-stage malignant tumors in various human organs.
引用
收藏
页码:173 / 177
页数:5
相关论文
共 35 条
  • [21] A quantitative study of the solute diffusion zone during solidification of Al-Cu alloys via in-situ synchrotron X-radiography and numerical simulation
    Jia, Yiwang
    Shang, Xiaojuan
    Yuan, Lang
    Yang, Guangkai
    Cao, Yuanzheng
    Shu, Da
    MATERIALS & DESIGN, 2024, 247
  • [22] Synchrotron-Radiation-Based Fourier Transform Infrared Microspectroscopy as a Tool for the Differentiation between Staphylococcal Small Colony Variants
    Al-Bakri, Amal G. G.
    Dahabiyeh, Lina A. A.
    Khalil, Enam
    Jaber, Deema
    Kamel, Gihan
    Schleimer, Nina
    Kohler, Christian
    Becker, Karsten
    ANTIBIOTICS-BASEL, 2022, 11 (11):
  • [23] Methodology for Analyzing Strain States During In Situ Thermomechanical Cycling in Individual Lead-Free Solder Joints Using Synchrotron Radiation
    Bieler, Thomas R.
    Lee, Tae-Kyu
    Liu, Kuo-Chuan
    JOURNAL OF ELECTRONIC MATERIALS, 2009, 38 (12) : 2712 - 2719
  • [24] Methodology for Analyzing Strain States During In Situ Thermomechanical Cycling in Individual Lead-Free Solder Joints Using Synchrotron Radiation
    Thomas R. Bieler
    Tae-kyu Lee
    Kuo-Chuan Liu
    Journal of Electronic Materials, 2009, 38 : 2712 - 2719
  • [25] In vivo and in situ synchrotron radiation-based μ-XRF reveals elemental distributions during the early attachment phase of barnacle larvae and juvenile barnacles
    Senkbeil, Tobias
    Mohamed, Tawheed
    Simon, Rolf
    Batchelor, David
    Di Fino, Alessio
    Aldred, Nick
    Clare, Anthony S.
    Rosenhahn, Axel
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (05) : 1487 - 1496
  • [26] In vivo and in situ synchrotron radiation-based μ-XRF reveals elemental distributions during the early attachment phase of barnacle larvae and juvenile barnacles
    Tobias Senkbeil
    Tawheed Mohamed
    Rolf Simon
    David Batchelor
    Alessio Di Fino
    Nick Aldred
    Anthony S. Clare
    Axel Rosenhahn
    Analytical and Bioanalytical Chemistry, 2016, 408 : 1487 - 1496
  • [27] Upgrade of the BioMUR beamline at the Kurchatov synchrotron radiation source for serial small-angle X-ray scattering experiments in solutions
    Peters, G. S.
    Gaponov, Yu A.
    Konarev, P., V
    Marchenkova, M. A.
    Ilina, K. B.
    Volkov, V. V.
    Pisarevsky, Yu, V
    Kovalchuk, M., V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1025
  • [28] In situ measurements of texture variations during a tensile loading of Mg-alloy AM20 using synchrotron X-ray radiation
    Yi, SB
    Brokmeier, HG
    Bolmaro, RE
    Kainer, KU
    Lippmann, T
    SCRIPTA MATERIALIA, 2004, 51 (05) : 455 - 460
  • [29] Focusing on delayed clearance for identifying small-sized metastatic lung tumors using synchrotron radiation angiography with a highly sensitive receiver.
    Ito H.
    Matsushita S.
    Hyodo K.
    Tsurushima H.
    Sato Y.
    Sakakibara Y.
    General Thoracic and Cardiovascular Surgery, 2014, 62 (9) : 553 - 559
  • [30] In situ X-ray observation of minerals and melts using Kawai-type multianvil apparatus combined with synchrotron radiation, and its applications to mineral physics
    Ohtani, E
    HIGH PRESSURE RESEARCH, 2004, 24 (04) : 531 - 550