Changes in the spectral powers of finger photoplethysmographic waveform variability in hemodialysis patients

被引:5
作者
Javed, Faizan [1 ]
Chan, Gregory S. H. [1 ]
Middleton, Paul M. [2 ]
Malouf, Philip [2 ]
Steel, Elizabeth [2 ]
Savkin, Andrey V. [1 ]
Mackie, James [2 ]
Lovell, Nigel H.
机构
[1] Univ New S Wales, Sch Elect Engn & Telecommun, Sydney, NSW 2052, Australia
[2] Prince Wales Hosp, Sydney, NSW, Australia
来源
2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20 | 2009年
基金
澳大利亚研究理事会;
关键词
HEART-RATE-VARIABILITY; HYPOTENSION; PRESSURE;
D O I
10.1109/IEMBS.2009.5333529
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper reports changes in the spectral powers of finger photoplethysmographic waveform variability (PPGV) following hemodialysis compared to pre-dialysis. The results are based on data collected from 12 hemodynamically stable patients having regular hemodialysis thrice weekly. Six minutes of continuous electrocardiogram (ECG) and finger infra-red photoplethysmographic (PPG) signals were collected at pre-dialysis and at end of dialysis. A four minute artefact free segment was selected and baseline and amplitude variabilities were derived from PPG waveform. Heart rate variability was derived from ECG R-R interval. Frequency spectrum analysis was then applied to these variability signals. The spectral powers were then calculated from low frequency (LF), mid frequency (MF) and high frequency (HF) bands. The results indicate that LF (p = 0.01) and MF (p = 0.02) powers of baseline PPGV (expressed in mean-scaled units) and LF (p = 0.006), MF (p = 0.003) and HF (p = 0.017) powers of amplitude PPGV (expressed in mean-scaled units) showed a significant increase at the end of dialysis compared to pre-dialysis. HRV spectral measures did not show any significant change. The increase in LF and MF powers in PPGV may suggest the recovery and further enhancement of peripheral sympathetic vascular modulation as a result of volume unloading in initially hypervolemic dialysis patients, at the same time the increase in respiratory HF power in PPGV may indicate preload reduction.
引用
收藏
页码:3999 / +
页数:2
相关论文
共 18 条
[1]  
AZANCOT I, 1977, CLIN NEPHROL, V8, P312
[2]  
Barnas MGW, 1999, J AM SOC NEPHROL, V10, P2577
[3]   Autonomic control of skin microvessels: Assessment by power spectrum of photoplethysmographic waves [J].
Bernardi, L ;
Radaelli, A ;
Solda, PL ;
Coats, AJS ;
Reeder, M ;
Calciati, A ;
Garrard, CS ;
Sleight, P .
CLINICAL SCIENCE, 1996, 90 (05) :345-355
[4]  
Camm AJ, 1996, EUR HEART J, V17, P354
[5]   Respiratory variations in pulse oximeter waveform amplitude are influenced by venous return in mechanically ventilated patients under general anaesthesia [J].
Cannesson, M. ;
Desebbe, O. ;
Hachemi, M. ;
Jacques, D. ;
Bastien, O. ;
Lehot, J. -J .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2007, 24 (03) :245-251
[6]   Autonomic nervous function during haemodialysis assessed by spectral analysis of heart-rate variability [J].
Cavalcanti, S ;
Severi, S ;
Chiari, L ;
Avanzolini, G ;
Enzmann, G ;
Bianco, F ;
Panzetta, G .
CLINICAL SCIENCE, 1997, 92 (04) :351-359
[7]   PARADOXICAL WITHDRAWAL OF REFLEX VASOCONSTRICTION AS A CAUSE OF HEMODIALYSIS-INDUCED HYPOTENSION [J].
CONVERSE, RL ;
JACOBSEN, TN ;
JOST, CMT ;
TOTO, RD ;
GRAYBURN, PA ;
OBREGON, TM ;
FOUADTARAZI, F ;
VICTOR, RG .
JOURNAL OF CLINICAL INVESTIGATION, 1992, 90 (05) :1657-1665
[8]   DIALYSIS HYPOTENSION - A HEMODYNAMIC ANALYSIS [J].
DAUGIRDAS, JT .
KIDNEY INTERNATIONAL, 1991, 39 (02) :233-246
[9]   Differences in heart rate variability during haemodialysis and haemofiltration [J].
Genovesi, Simonetta ;
Bracchi, Oscar ;
Fabbrini, Paolo ;
Luisetto, Elena ;
Vigano, Maria Rosa ;
Lucini, Daniela ;
Malacarne, Mara ;
Stella, Andrea ;
Pagani, Massimo .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2007, 22 (08) :2256-2262
[10]   Impact of withdrawal of 450 ml of blood on respiration-induced oscillations of the ear plethysmographic waveform [J].
Gesquiere M.J. ;
Awad A.A. ;
Silverman D.G. ;
Stout R.G. ;
Jablonka D.H. ;
Silverman T.J. ;
Shelley K.H. .
Journal of Clinical Monitoring and Computing, 2007, 21 (05) :277-282