Shear behavior of large stud shear connectors embedded in ultra-high-performance concrete

被引:40
作者
Hu, Yuqing [1 ]
Yin, Huiguang [2 ]
Ding, Xiaomeng [1 ]
Li, Shuai [1 ]
Wang, J. Q. [1 ]
机构
[1] Southeast Univ, 2 Sipailou Rd, Nanjing 210096, Peoples R China
[2] Xuzhou Univ Technol, Xuzhou, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
large-headed stud; numerical analysis; push-out test; shear behavior; ultra-high-performance concrete (UHPC); PUSH-OUT TESTS; STATIC BEHAVIOR; HIGH-STRENGTH; STEEL; RESISTANCE; BRIDGES; MODEL;
D O I
10.1177/1369433220939208
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this article, the static shear behavior of large-headed studs embedded in ultra-high-performance concrete was investigated by push-out test and numerical analysis. A total of nine push-out specimens with single and grouped studs embedded in ultra-high-performance concrete and normal strength concrete slabs were tested. In the testing process, only shank failure appeared without cracks occurring on the surface of ultra-high-performance concrete slab when the steel-ultra-high-performance concrete specimens reached ultimate shear capacity. The shear capacity of specimens with large studs embedded in ultra-high-performance concrete slab increased by 10.6% compared those in normal concrete, and the current design codes such as Eurocode4, AASHTO LFRD 2014, and GB50017-2003 all underestimate the shear capacity of such kind of steel-ultra-high-performance concrete composite structures according to experimental results. Numerical models were established using ABAQUS with introducing damage plasticity material model. The influence of stud diameter, concrete strength, thickness of clear cover, and spacing of studs on the static shear behavior was thoroughly investigated via parametric analysis. Based on the experimental and numerical analysis, the existence of wedge block and the decrease of axis force are beneficial for improving the shear capacity of stud shear connectors.
引用
收藏
页码:3401 / 3414
页数:14
相关论文
共 46 条
[1]   Shear resistance of the perfobond-rib shear connector depending on concrete strength and rib arrangement [J].
Ahn, Jin-Hee ;
Lee, Chan-Goo ;
Won, Jeong-Hun ;
Kim, Sang-Hyo .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (10) :1295-1307
[2]   Push-out tests on studs in high strength and normal strength concrete [J].
An, L ;
Cederwall, K .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1996, 36 (01) :15-29
[3]  
[Anonymous], 2003, 500172003 MOHURD GB
[4]  
[Anonymous], 2014, AASHTO LRFD Bridge Design Specifications, V7
[5]  
[Anonymous], 2006, FHWA HRT 06 103
[6]  
Badie S.S., 2002, J BRIDGE ENG, V7, P195, DOI DOI 10.1061/(ASCE)1084-0702(2002)7:3(195)
[7]   Experimental evaluation of the structural response of Perfobond shear connectors [J].
Candido-Martins, J. P. S. ;
Costa-Neves, L. F. ;
Vellasco, P. C. G. da S. .
ENGINEERING STRUCTURES, 2010, 32 (08) :1976-1985
[8]   Static and Fatigue Behavior of Short-Headed Studs Embedded in a Thin Ultrahigh-Performance Concrete Layer [J].
Cao, Junhui ;
Shao, Xudong ;
Deng, Lu ;
Gan, Yidong .
JOURNAL OF BRIDGE ENGINEERING, 2017, 22 (05)
[9]  
Code-Steel SW, 2000, D112000 ANSIAWS
[10]   Use of UHPFRC overlay to reduce stresses in orthotropic steel decks [J].
Dieng, Lamine ;
Marchand, Pierre ;
Gomes, Fernanda ;
Tessier, Christian ;
Toutlemonde, Francois .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2013, 89 :30-41