Low-cost and automated calibration method for joint offset of industrial robot using single-point constraint

被引:16
作者
Liu, Yong [1 ]
Xi, Ning [2 ]
机构
[1] Nanjing Univ Sci & Technol, Sch Comp Sci & Technol, Nanjing, Peoples R China
[2] Michigan State Univ, Dept Elect & Comp Engn, E Lansing, MI 48824 USA
来源
INDUSTRIAL ROBOT-THE INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH AND APPLICATION | 2011年 / 38卷 / 06期
关键词
Robots; Calibration; Precision; Virtual lines-based; Single-point constraint; PSD-based calibration device; TRACKING;
D O I
10.1108/01439911111179093
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Purpose - The industrial robot has high repeatability but low accuracy. With the industrial robot being widely used in complicated tasks, e.g. arc welding, offline programming and surgery, accuracy of the robot is more and more important. Robot calibration is an efficient way to improve the accuracy. Previous methods such as using coordinate measurement machines, laser trackers or cameras are limited by the cost, complex operation or the resolution. The purpose of this paper is to propose an approach and calibration equipment to address these issues. Design/methodology/approach - The proposed method relies mainly upon a laser pointer attached on the end-effector and single position-sensitive devices (PSD) arbitrarily located on the workcell. The automated calibration procedure (about three minutes) involves aiming the laser lines loaded by the robot towards the center of the PSD surface from various robot positions and orientations. The localization is guaranteed by precise PSD feedback servoing control, which means physically the intersections of each pair of laser lines (virtual lines) are on the same point. Based on the untouched single-point constraint, the robot joint offset calibration is implemented. Using the authors' proposed approach, a portable, low-cost, battery-powered, wireless and automated calibration system was implemented. Error analysis was conducted on the system. Findings - The localization error of the developed calibration system is within 2 mu m. The errors in joint space are magnified in PSD plane, and consequently the resolution in the joint space is improved. The standard deviation of the identified parameters was small (10-2), indicating the stability of the calibration method. Both simulation and experimental results verify the feasibility of the proposed method and demonstrate the developed calibration system can identify joint offset with uncalibrated laser tool parameters. Originality/value - The paper shows how a portable calibration system for joint offset of industrial robots was developed and how the goal of fast, automated, low-cost, portable, and high precision calibration methods for joint offset was achieved.
引用
收藏
页码:577 / 584
页数:8
相关论文
共 7 条
  • [1] An Automated Method to Calibrate Industrial Robot Joint Offset Using Virtual Line-based Single-point Constraint Approach
    Liu, Yong
    Xi, Ning
    Zhang, George
    Li, Xiongzi
    Chen, Heping
    Zhang, Chi
    Jeffery, Michael J.
    Fuhlbrigge, Thomas A.
    2009 IEEE-RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, 2009, : 715 - 720
  • [2] A LOW-COST CALIBRATION METHOD FOR AUTOMATED OPTICAL MENSURATION USING A VIDEO CAMERA
    WANG, CC
    MACHINE VISION AND APPLICATIONS, 1994, 7 (04) : 259 - 266
  • [3] Calibration of Low-Cost Particle Sensors by Using Machine-Learning Method
    Chen, Chen-Chia
    Kuo, Chih-Ting
    Chen, Ssu-Ying
    Lin, Chih-Hsing
    Chue, Jin-Ju
    Hsieh, Yi-Jie
    Cheng, Chun-Wen
    Wu, Chieh-Ming
    Huang, Chun-Ming
    2018 IEEE ASIA PACIFIC CONFERENCE ON CIRCUITS AND SYSTEMS (APCCAS 2018), 2018, : 111 - 114
  • [4] A Method for Turning a Single Low-Cost Cube into a Reference Target for Point Cloud Registration
    Chan, Ting On
    Xia, Linyuan
    Lichti, Derek D. D.
    Wang, Xuanqi
    Peng, Xiong
    Cai, Yuezhen
    Li, Ming Ho
    APPLIED SCIENCES-BASEL, 2023, 13 (03):
  • [5] A Portable and Low-Cost 3D Tracking System Using Four-Point Planar Square Calibration
    Peltola, Pekka
    Valtonen, Miika
    Vanhala, Jukka
    2012 INTERNATIONAL CONFERENCE ON INDOOR POSITIONING AND INDOOR NAVIGATION (IPIN), 2012,
  • [6] A Novel Method of Human Joint Prediction in an Occlusion Scene by Using Low-Cost Motion Capture Technique
    Niu, Jianwei
    Wang, Xiai
    Wang, Dan
    Ran, Linghua
    SENSORS, 2020, 20 (04)
  • [7] DETERMINATION OF IRON(III) AND TITANIUM(IV) AS THEIR SOLOCHROME VIOLET RS COMPLEXES BY CONSTANT-CURRENT STRIPPING POTENTIOMETRY .1. AUTOMATED SINGLE-POINT CALIBRATION METHOD FOR IRON(III)
    JAGNER, D
    RENMAN, L
    STEFANSDOTTIR, SH
    ANALYTICA CHIMICA ACTA, 1993, 281 (02) : 305 - 314