Design and test of an Electronic Nose for monitoring the air quality in the International Space Station

被引:8
作者
Martinelli, E. [1 ]
Zampetti, E. [1 ]
Pantalei, S. [1 ]
Lo Castro, F. [1 ]
Santonico, M. [1 ]
Pennaa, G. [1 ]
Paolesse, R. [1 ]
Mascetti, G. [2 ]
Cotronei, V. [2 ]
Giannini, F. [1 ]
Di Natale, C. [1 ]
DAmico, A. [1 ]
机构
[1] Univ Roma Tor Vergata, Dept Elect Engn, I-00133 Rome, Italy
[2] Italian Space Agcy, I-00198 Rome, Italy
关键词
International Space Station; Failure Condition; Electronic Nose; Animal Cage; Depuration System;
D O I
10.1007/BF02919454
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Long-term manned space missions requires a continuous monitoring of the air quality inside the spacecraft. For this scope, among several different solutions, electronic noses have been considered. On behalf of European Space Agency an electronic nose specifically designed for air quality control in closed environment is under development. After several ground experiments concerning the monitoring of a biofilter efficiency, the instrument has been tested during the ENEIDE mission on board of the International Space Station. in this paper the instrument main concepts and its performance in ground and space experiments are illustrated.
引用
收藏
页码:60 / 64
页数:5
相关论文
共 11 条
[1]   Technologies and tools for mimicking olfaction: status of the Rome "Tor Vergata" electronic nose [J].
D'Amico, A ;
Di Natale, C ;
Macagnano, A ;
Davide, F ;
Mantini, A ;
Tarizzo, E ;
Paolesse, R ;
Boschi, T .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (06) :711-721
[2]   Lung cancer identification by the analysis of breath by means of an array of non-selective gas sensors [J].
Di Natale, C ;
Macagnano, A ;
Martinelli, E ;
Paolesse, R ;
D'Arcangelo, G ;
Roscioni, C ;
Finazzi-Agrò, A ;
D'Amico, A .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (10) :1209-1218
[3]  
MARTINELLI G, 3 IEEE SENS C VIENN
[4]  
Mergaey M., 1988, P 3 S SPAC THERM CON, P65
[5]  
NAGLE T, 2003, HDB MACHINE OLFACTIO
[6]   ANALYSIS OF DISCRIMINATION MECHANISMS IN THE MAMMALIAN OLFACTORY SYSTEM USING A MODEL NOSE [J].
PERSAUD, K ;
DODD, G .
NATURE, 1982, 299 (5881) :352-355
[7]   A smart gas sensor for monitoring environmental changes in closed systems: results from the MIR space station [J].
Persaud, KC ;
Pisanelli, AM ;
Szyszko, S ;
Reichl, M ;
Horner, G ;
Rakow, W ;
Keding, HJ ;
Wessels, H .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 55 (2-3) :118-126
[8]   Monitoring space shuttle air quality using the jet propulsion laboratory electronic nose [J].
Ryan, MA ;
Zhou, HY ;
Buehler, MG ;
Manatt, KS ;
Mowrey, VS ;
Jackson, SR ;
Kisor, AK ;
Shevade, AV ;
Homer, ML .
IEEE SENSORS JOURNAL, 2004, 4 (03) :337-347
[9]   RECEPTOR CELL RESPONSES TO ODORANTS - SIMILARITIES AND DIFFERENCES AMONG ODORANTS [J].
SICARD, G ;
HOLLEY, A .
BRAIN RESEARCH, 1984, 292 (02) :283-296
[10]   Monitoring of biological odour filtration in closed environments with olfactometry and an electronic nose [J].
Willers, H ;
de Gijsel, P ;
Ogink, N ;
D'Amico, A ;
Martinelli, E ;
Di Natale, C ;
van Ras, N ;
van der Waarde, J .
WATER SCIENCE AND TECHNOLOGY, 2004, 50 (04) :93-100