Comparison of gas chromatographic hyphenated techniques for mercury speciation analysis

被引:57
作者
Berzas Nevado, J. J. [2 ]
Rodriguez Martin-Doimeadios, R. C. [1 ]
Krupp, E. M. [3 ]
Guzman Bernardo, F. J. [1 ]
Rodriguez Farinas, N. [1 ]
Jimenez Moreno, M. [1 ]
Wallace, D. [3 ]
Patino Roper, M. J. [1 ]
机构
[1] Univ Castilla La Mancha, Fac Environm Sci & Biochem, Dept Analyt Chem & Food Technol, E-45071 Toledo, Spain
[2] Univ Castilla La Mancha, Fac Chem, Dept Analyt Chem & Food Technol, E-16071 Ciudad Real, Spain
[3] Univ Aberdeen, Coll Phys Sci, Aberdeen AB24 3UE, Scotland
关键词
Mercury speciation; Gas chromatography; Atomic fluorescence spectrometry; Mass spectrometry; Inductively coupled plasma mass spectrometry; Hyphenated techniques; ATOMIC FLUORESCENCE DETECTION; MULTIPLE PESTICIDE-RESIDUES; ISOTOPE-DILUTION ANALYSIS; ENVIRONMENTAL-SAMPLES; MASS SPECTROMETRY; HYDRIDE GENERATION; BIOLOGICAL TISSUES; METHYLMERCURY; MONOBUTYLTIN; TRIBUTYLTIN;
D O I
10.1016/j.chroma.2011.05.036
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, we evaluate advantages and disadvantages of three hyphenated techniques for mercury speciation analysis in different sample matrices using gas chromatography (GC) with mass spectrometry (GC-MS), inductively coupled plasma mass spectrometry (GC-ICP-MS) and pyrolysis atomic fluorescence (GC-pyro-AFS) detection. Aqueous ethylation with NaBEt4 was required in all cases. All systems were validated with respect to precision, with repeatability and reproducibility <5% RSD, confirmed by the Snedecor F-test. All methods proved to be robust according to a Plackett-Burnham design for 7 factors and 15 experiments, and calculations were carried out using the procedures described by Youden and Steiner. In order to evaluate accuracy, certified reference materials (DORM-2 and DOLT-3) were analyzed after closed-vessel microwave extraction with tetramethylammonium hydroxide (TMAH). No statistically significant differences were found to the certified values (p = 0.05). The suitability for water samples analysis with different organic matter and chloride contents was evaluated by recovery experiments in synthetic spiked waters. Absolute detection and quantification limits were in the range of 2-6 pg for GC-pyro-AFS, 1-4 pg for GC-MS, with 0.05-0.21 pg for GC-ICP-MS showing the best limits of detection for the three systems employed. However, all systems are sufficiently sensitive for mercury speciation in environmental samples, with GC-MS and GC-ICP-MS offering isotope analysis capabilities for the use of species-specific isotope dilution analysis, and GC-pyro-AFS being the most cost effective alternative. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:4545 / 4551
页数:7
相关论文
共 34 条
  • [1] [Anonymous], 1946, Biometrika, DOI [DOI 10.2307/2332195, DOI 10.1093/BIOMET/33.4.305]
  • [2] Indirect mercury speciation in biological tissues by closed-vessel microwave-assisted digestion and flow-injection cold-vapor atomic fluorescence detection
    Berzas Nevado, J. J.
    Rodriguez Martin-Doimeadios, R. C.
    Guzman Bernardo, F. J.
    Jimenez Moreno, M.
    [J]. ANALYTICAL LETTERS, 2006, 39 (14) : 2657 - 2669
  • [3] Bloom Nicolas S., 1994, P541
  • [4] Ecological effects, transport, and fate of mercury: a general review
    Boening, DW
    [J]. CHEMOSPHERE, 2000, 40 (12) : 1335 - 1351
  • [5] Isotope dilution SPME GC/MS for the determination of methylmercury in tuna fish samples
    Centineo, G
    González, EB
    Alonso, JIG
    Sanz-Medel, A
    [J]. JOURNAL OF MASS SPECTROMETRY, 2006, 41 (01): : 77 - 83
  • [6] Simultaneous determination of mono-, di- and tributyltin in environmental samples using isotope dilution gas chromatography mass spectrometry
    Centineo, G
    Rodríguez-González, P
    González, EB
    Alonso, JIG
    Sanz-Medel, A
    [J]. JOURNAL OF MASS SPECTROMETRY, 2004, 39 (05): : 485 - 494
  • [7] Craig P.J., 1986, ORGANOMETALLIC COMPO
  • [8] Interferences during mercury speciation determination by volatilization, cryofocusing, gas chromatography and atomic absorption spectroscopy: comparative study between hydride generation and ethylation techniques
    de Diego, A
    Tseng, CM
    Stoichev, T
    Amouroux, D
    Donard, OFX
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (07) : 623 - 629
  • [9] Ruggedness and robustness testing
    Dejaegher, Bieke
    Vander Heyden, Yvan
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1158 (1-2) : 138 - 157
  • [10] Validation of methylmercury determinations in aquatic systems by alkyl derivatization methods for GC analysis using ICP-IDMS
    Demuth, N
    Heumann, KG
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (16) : 4020 - 4027