Ionizer Assisted Air Filtration for Collection of Submicron and Ultrafine Particles-Evaluation of Long-Term Performance and Influencing Factors

被引:60
|
作者
Shi, Bingbing [1 ]
Ekberg, Lars [1 ,2 ]
机构
[1] Chalmers Univ Technol, Environm & Energy Dept, S-41296 Gothenburg, Sweden
[2] CIT Energy Management AB, S-41258 Gothenburg, Sweden
基金
瑞典研究理事会;
关键词
AEROSOL-PARTICLES; INDOOR AIR; FILTERS; REMOVAL; FINE; VENTILATION; EFFICIENCY; EXPOSURE;
D O I
10.1021/acs.est.5b00974
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Previous research has demonstrated that unipolar ionization can enhance the filter performance to collect airborne particles, aeroallergens, and airborne microorganisms, without affecting the filter pressure drop. However, there is a lack of research on the long-term system performance as well as the influence of environmental and operational parameters. In this paper, both field and laboratory tests were carried out to evaluate the long-term particle collection efficiency of a synthetic filter of class M6 with and without ionization. The effect of air velocity, temperature, relative humidity, and particle concentration were further investigated in laboratory tests. Results showed that ionization enhanced the filtration efficiency by 40%-units during most of the operation time. When the ionization system was managed by periodically switching the ionizer polarity, the filtration efficiency against PM0.3-0.5 was maintained above 50% during half a year. Furthermore, the pressure drop of the ionizer-assisted M6 filter was 25-30% lower than that of a filter of class F7. The evaluation of various influencing factors demonstrated that (1) air moisture reduced the increase of filtration efficiency; (2) higher upstream particle concentration and air velocity decreased the filtration efficiency; and (3) the air temperature had very limited effect on the filtration efficiency.
引用
收藏
页码:6891 / 6898
页数:8
相关论文
共 36 条
  • [21] Los Angeles Basin's air quality transformation: A long-term investigation on the impacts of PM regulations on the trends of ultrafine particles and co-pollutants
    Badami, Mohammad Mahdi
    Tohidi, Ramin
    Sioutas, Constantinos
    JOURNAL OF AEROSOL SCIENCE, 2024, 176
  • [22] Long-term prognosis for Guillain-Barre syndrome: Evaluation of prognostic factors and clinical experience of automated double filtration plasmapheresis
    Cheng, BC
    Chang, WN
    Chen, JB
    Chee, ECY
    Huang, CR
    Lu, CH
    Chang, CJ
    Hung, PL
    Chuang, YC
    Lee, CT
    Lee, PY
    Wang, KW
    Chang, HW
    JOURNAL OF CLINICAL APHERESIS, 2003, 18 (04) : 175 - 180
  • [23] Evaluation of the Long-Term Effect of Air Filtration on the Occurrence of New PRRSV Infections in Large Breeding Herds in Swine-Dense Regions
    Dee, Scott
    Cano, Jean Paul
    Spronk, Gordon
    Reicks, Darwin
    Ruen, Paul
    Pitkin, Andrea
    Polson, Dale
    VIRUSES-BASEL, 2012, 4 (05): : 654 - 662
  • [24] Influencing factors analysis for the long-term thermal performance of medium and deep U-type borehole heat exchanger system
    Huang, Shuai
    Li, Jiqin
    Zhu, Ke
    Dong, Jiankai
    Jiang, Yiqiang
    JOURNAL OF BUILDING ENGINEERING, 2023, 68
  • [25] Evaluation of Factors Affecting Long-Term Performance of Cold In-Place Recycled Pavements in New York State
    Chesner, Warren H.
    Stein, Christopher W.
    Justus, Henry G.
    Kearney, Edward R.
    Cross, Stephen A.
    TRANSPORTATION RESEARCH RECORD, 2011, (2227) : 13 - 22
  • [26] Evaluation of organics reduction performance of the GAC filtration with regenerated carbons using the long-term operational data of drinking water treatment facilities
    Kim, Seung-Hyun
    Kim, Sanggoo
    Yoom, Hoonsik
    Son, Heejong
    AQUA-WATER INFRASTRUCTURE ECOSYSTEMS AND SOCIETY, 2022, 71 (10) : 1219 - 1228
  • [27] Spatiotemporal profiles of ultrafine particles differ from other traffic-related air pollutants: lessons from long-term measurements at fixed sites and mobile monitoring
    Gani, Shahzad
    Chambliss, Sarah E.
    Messier, Kyle P.
    Lunden, Melissa M.
    Apte, Joshua S.
    ENVIRONMENTAL SCIENCE-ATMOSPHERES, 2021, 1 (07): : 558 - 568
  • [28] Long-Term Evaluation of Comfort, Indoor Air Quality and Energy Performance in Buildings: The Case of the KTH Live-In Lab Testbeds
    Rolando, Davide
    Pallard, Willem Mazzotti
    Molinari, Marco
    ENERGIES, 2022, 15 (14)
  • [29] Development of a general calibration model and long-term performance evaluation of low-cost sensors for air pollutant gas monitoring
    Malings, Carl
    Tanzer, Rebecca
    Hauryliuk, Aliaksei
    Kumar, Sriniwasa P. N.
    Zimmerman, Naomi
    Kara, Levent B.
    Presto, Albert A.
    Subramanian, R.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2019, 12 (02) : 903 - 920
  • [30] High performance liquid chromatographic measurement of iothalamate in human serum and urine for the estimation and long-term follow-up evaluation of glomerular filtration rate.
    Bi, D.
    Leary, K. J.
    Weitz, J. A.
    Cherstiniakova, S. A.
    Riel, M. A.
    Roy, M. J.
    Cantilena, L. R.
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 2007, 81 : S55 - S55