Ionizer Assisted Air Filtration for Collection of Submicron and Ultrafine Particles-Evaluation of Long-Term Performance and Influencing Factors

被引:60
|
作者
Shi, Bingbing [1 ]
Ekberg, Lars [1 ,2 ]
机构
[1] Chalmers Univ Technol, Environm & Energy Dept, S-41296 Gothenburg, Sweden
[2] CIT Energy Management AB, S-41258 Gothenburg, Sweden
基金
瑞典研究理事会;
关键词
AEROSOL-PARTICLES; INDOOR AIR; FILTERS; REMOVAL; FINE; VENTILATION; EFFICIENCY; EXPOSURE;
D O I
10.1021/acs.est.5b00974
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Previous research has demonstrated that unipolar ionization can enhance the filter performance to collect airborne particles, aeroallergens, and airborne microorganisms, without affecting the filter pressure drop. However, there is a lack of research on the long-term system performance as well as the influence of environmental and operational parameters. In this paper, both field and laboratory tests were carried out to evaluate the long-term particle collection efficiency of a synthetic filter of class M6 with and without ionization. The effect of air velocity, temperature, relative humidity, and particle concentration were further investigated in laboratory tests. Results showed that ionization enhanced the filtration efficiency by 40%-units during most of the operation time. When the ionization system was managed by periodically switching the ionizer polarity, the filtration efficiency against PM0.3-0.5 was maintained above 50% during half a year. Furthermore, the pressure drop of the ionizer-assisted M6 filter was 25-30% lower than that of a filter of class F7. The evaluation of various influencing factors demonstrated that (1) air moisture reduced the increase of filtration efficiency; (2) higher upstream particle concentration and air velocity decreased the filtration efficiency; and (3) the air temperature had very limited effect on the filtration efficiency.
引用
收藏
页码:6891 / 6898
页数:8
相关论文
共 36 条
  • [1] Electrostatically assisted air coarse filtration for energy efficient ambient particles removal: Long-term performance in real environment and influencing factors
    Tian, Enze
    Gao, Yilun
    Mo, Jinhan
    BUILDING AND ENVIRONMENT, 2019, 164
  • [2] Influence of Filter Fiber Material on Removal of Ultrafine and Submicron Particles Using Carbon Fiber Ionizer-Assisted Intermediate Air Filters
    Shi, Bingbing
    Ekberg, Lars E.
    Truschel, Anders
    Gusten, Jan
    ASHRAE TRANSACTIONS 2012, VOL 118, PT 1, 2012, 118 : 602 - 611
  • [3] Long-Term Evaluation of Cold-in-Place Recycling and Factors Influencing Performance
    Buss, Ashley
    Mercado, Marie Grace
    Schram, Scott
    JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2017, 31 (03)
  • [4] FACTORS INFLUENCING RESULTS IN STAPES SURGERY A LONG-TERM EVALUATION
    SHAMBAUGH, GE
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1967, 76 (03): : 599 - +
  • [5] A two-stage cascaded ionizer for boosting PM charging in electrostatic filtration: Principles, design, and long-term performance
    Gao, Yilun
    Gu, Yuting
    Tian, Enze
    Mo, Jinhan
    SEPARATION AND PURIFICATION TECHNOLOGY, 2023, 313
  • [6] C-reactive protein (CRP) and long-term air pollution with a focus on ultrafine particles
    Pilz, Veronika
    Wolf, Kathrin
    Breitner, Susanne
    Rueckerl, Regina
    Koenig, Wolfgang
    Rathmann, Wolfgang
    Cyrys, Josef
    Peters, Annette
    Schneider, Alexandra
    INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2018, 221 (03) : 510 - 518
  • [7] Evaluation of speech outcomes in hemiglossectomy: Factors influencing long-term results
    Kim, Tae Hyung
    Kim, Young Chul
    Choi, Jong Woo
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2024, 99 : 185 - 192
  • [8] Evaluation of factors influencing long-term and textbook outcomes in laparoscopic gastrectomy
    Lin, Xia
    Tan, Chenjun
    Wu, Weigao
    Liang, Chenglong
    Qian, Feng
    Zhao, Yongliang
    EJSO, 2024, 50 (03):
  • [9] Factors Influencing New RNs' Supervisory Performance in Long-Term Care Facilities
    Prentice, Dawn
    Boscart, Veronique
    McGilton, Katherine S.
    Escrig, Astrid
    CANADIAN JOURNAL ON AGING-REVUE CANADIENNE DU VIEILLISSEMENT, 2017, 36 (04): : 463 - 471
  • [10] EVALUATION OF PROGNOSTIC FACTORS ON THE LONG-TERM PERFORMANCE OF COPPER IUDS
    ALLONEN, H
    LUUKKAINEN, T
    PYORALA, T
    NIELSEN, NC
    NYGREN, KG
    CONTRACEPTIVE DELIVERY SYSTEMS, 1983, 4 (04) : 50 - 50