In vivo nitric oxide sensor using non-conducting polymer-modified carbon fiber

被引:87
作者
Park, JK [1 ]
Tran, PH [1 ]
Chao, JKT [1 ]
Ghodadra, R [1 ]
Rangarajan, R [1 ]
Thakor, NV [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Biomed Engn, Baltimore, MD 21205 USA
关键词
nitric oxide; in vivo sensor; carbon fiber; Nafion; m-phenylenediamine; resorcinol;
D O I
10.1016/S0956-5663(98)00078-5
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Nitric oxide (NO) is emerging as a very important and ubiquitous gaseous messenger in the body. The response characteristics of NO sensors made of non-conducting polymer modified carbon fiber electrodes are investigated to determine their selectivity, sensitivity, and stability for in vivo use. A composite polymer, comprising Nafion, m-phenylenediamine, and resorcinol, showed the best selectivity and stability to amperometric NO detection. The non-conducting, self-limiting polymer film protects the electrode from interference and fouling by other biochemicals. Although the relative sensitivity to NO of the modified sensor is lower than that of the unmodified carbon fiber electrodes (less than 6%), the composite polymer electrode showed high selectivity against ascorbic acid ( > 2000:1), nitrite ( > 600:1), and dopamine ( > 200:1). The stability of the NO sensor was maintained for at least 1 week. The NO sensitivity after in vivo experiments (n = 8) is 88.1 +/- 5.6% of initial sensitivity data obtained before in vivo experiments. Preliminary in vivo experiments done with this electrode are shown to capture elevated NO levels in brain following an ischemic injury. (C) 1998 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:1187 / 1195
页数:9
相关论文
共 27 条
  • [11] GILBERT DL, 1994, ANN NY ACAD SCI, V738, P1
  • [12] ELECTROCHEMICAL TREATMENT OF PYROLYTIC CARBON-FIBER ELECTRODES
    GONON, FG
    FOMBARLET, CM
    BUDA, MJ
    PUJOL, JF
    [J]. ANALYTICAL CHEMISTRY, 1981, 53 (09) : 1386 - 1389
  • [13] PRINCIPLES OF VOLTAMMETRY AND MICROELECTRODE SURFACE-STATES
    KAWAGOE, KT
    ZIMMERMAN, JB
    WIGHTMAN, RM
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 1993, 48 (03) : 225 - 240
  • [14] SELECTIVE AND SENSITIVE ELECTROCHEMICAL MEASUREMENT OF NITRIC-OXIDE IN AQUEOUS-SOLUTION - DISCUSSION AND NEW RESULTS
    LANTOINE, F
    TREVIN, S
    BEDIOUI, F
    DEVYNCK, J
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 392 (1-2): : 85 - 89
  • [15] Miniaturized biosensors employing electropolymerized permselective films and their use for creatinine assays in human serum
    Madaras, MB
    Buck, RP
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (21) : 3832 - 3839
  • [16] Malinski T, 1996, METHOD ENZYMOL, V268, P58
  • [17] NITRIC-OXIDE RELEASE FROM A SINGLE CELL MEASURED INSITU BY A PORPHYRINIC-BASED MICROSENSOR
    MALINSKI, T
    TAHA, Z
    [J]. NATURE, 1992, 358 (6388) : 676 - 678
  • [18] GLUCOSE FAST-RESPONSE AMPEROMETRIC SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN ELECTROPOLYMERIZED POLY(ORTHO-PHENYLENEDIAMINE) FILM
    MALITESTA, C
    PALMISANO, F
    TORSI, L
    ZAMBONIN, PG
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (24) : 2735 - 2740
  • [19] GALACTOSE BIOSENSORS USING COMPOSITE POLYMERS TO PREVENT INTERFERENCES
    MANOWITZ, P
    STOECKER, PW
    YACYNYCH, AM
    [J]. BIOSENSORS & BIOELECTRONICS, 1995, 10 (3-4) : 359 - 370
  • [20] MOGHADDAM B, 1995, ANN NY ACAD SCI, V738, P106