Computational Fluid Dynamics and Experimental Analysis of the Heat Transfer in a Room With a Roof Solar Chimney

被引:5
|
作者
Vazquez-Ruiz, A. [1 ]
Navarro, J. M. A. [1 ]
Hinojosa, J. F. [1 ]
Xaman, J. P. [2 ]
机构
[1] Sonora Univ, Dept Chem Engn & Met, Hermosillo 83000, Sonora, Mexico
[2] CENIDET DGEST SEP, Natl Ctr Technol Res & Dev, Prol Av Palmira S-N Col Palmira, Cuernavaca 62490, Morelos, Mexico
关键词
scaled room; solar chimney; double-channel solar chimney; numerical- experimental study; energy efficiency; energy systems; experimental techniques; natural and mixed convection; thermal systems; NATURAL VENTILATION; PERFORMANCE; WALL; BUILDINGS; CONVECTION; DESIGN; SYSTEM; LOAD; FLOW;
D O I
10.1115/1.4051454
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study reports a numerical-experimental analysis of heat transfer and airflow in a scaled room with a heated wall coupled with a double-channel vertical roof solar chimney. For the experimental part, a parametric study was performed in the thermal system, considering different values of heat flux supplied to a vertical wall of the scaled room (75 and 150 W/m(2)) and the absorber surface of the solar chimney (151 and 667 W/m(2)). Experimental temperature profiles were obtained at six different depths and heights, and experimental heat transfer coefficients were computed for both heated surfaces. The renormalization group k-e turbulence model was evaluated against experimental data using computational fluid dynamics software. With the validated model, the effect of the heated wall and solar chimney on temperature fields, flow patterns, and heat transfer convective coefficients are presented and discussed. The cases with heat flux on the heated wall of the scaled room produce the biggest air changes per hour (ACH), being 30.1, 31.2, and 23.4 ACH for cases 1 to 3, respectively, while cases with no heated wall produce fewer ACH (11.72 and 12.28 for case 4 and 5). The comparison between cases with and without heat flux on one vertical wall but the same solar chimney heat flux shows that the ACH increases between 154% and 156%, respectively.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Effect of the solar roof chimney position on heat transfer in a room
    Vazquez-Ruiz, A.
    Navarro, J. M. A.
    Hinojosa, J. F.
    Xaman, J. . P.
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2021, 209
  • [2] Transient Thermal Analysis of a Double Duct Solar Roof Chimney Coupled With a Scaled Room
    Navarro, J. M. A.
    Vazquez-Ruiz, A.
    Hinojosa, J. F.
    Moreno, S.
    Maytorena, V. M.
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2024, 146 (01):
  • [3] CFD (computational fluid dynamics) analysis of a solar-chimney power plant with inclined collector roof
    Gholamalizadeh, Ehsan
    Kim, Man-Hoe
    ENERGY, 2016, 107 : 661 - 667
  • [4] Utilization of cool ceiling with roof solar chimney in Thailand: The experimental and numerical analysis
    Chungloo, Sudaporn
    Limmeechokchai, Bundit
    RENEWABLE ENERGY, 2009, 34 (03) : 623 - 633
  • [5] Computational Heat Transfer and Fluid Dynamics
    Miroshnichenko, Igor V.
    AXIOMS, 2023, 12 (08)
  • [6] Computational Fluid Dynamics and Heat Transfer Analysis of Vortex Formation in a Solar Reactor
    Chien, Min-Hsiu
    Ozalp, Nesrin
    Morrison, Gerald
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2015, 7 (04)
  • [7] Experimental and numerical analysis of the influence of inlet configuration on the performance of a roof top solar chimney
    Al-Kayiem, Hussain H.
    Sreejaya, K. V.
    Chikere, Aja O.
    ENERGY AND BUILDINGS, 2018, 159 : 89 - 98
  • [8] Fluid dynamics analysis for different photovoltaic panel locations in solar chimney
    Haghighat, Siavash
    Kasaeian, Alibakhsh
    Pourfayaz, Fathollah
    Shandost, Bagher Mokhtari
    ENERGY CONVERSION AND MANAGEMENT, 2019, 191 : 71 - 79
  • [9] Experimental investigation and mathematical modelling of the heat and mass transfer processes in a solar chimney
    Wang, Jiachen
    Guo, Jinchi
    Liu, Cui
    Li, Yongcai
    Li, Chunhua
    RENEWABLE ENERGY, 2024, 237
  • [10] Computational fluid dynamics analysis of heat transfer in a greenhouse solar dryer "chapel-type" coupled to an air solar heating system
    Roman-Roldan, Nicolas-Ivan
    Lopez-Ortiz, Anabel
    Ituna-Yudonago, Jean-Fulbert
    Garcia-Valladares, Octavio
    Pilatowsky-Figueroa, Isaac
    ENERGY SCIENCE & ENGINEERING, 2019, 7 (04) : 1123 - 1139