Thermal resistance measurement across a wick structure using a novel thermosyphon test chamber

被引:28
作者
Davis, T. W. [1 ]
Garimella, S. V. [1 ]
机构
[1] Purdue Univ, Sch Mech Engn, Cooling Technol Res Ctr, W Lafayette, IN 47907 USA
基金
美国国家科学基金会;
关键词
heat pipe; thermal resistance; thermosyphon; sintered copper wick;
D O I
10.1080/08916150701815853
中图分类号
O414.1 [热力学];
学科分类号
摘要
A novel system is developed for measuring the thermal resistance across thin layers of sintered copper wicks of varying porosity. Wicks to be tested are integrated into a passive vertical thermosyphon system, and the resistance is measured for a series of input power levels. The wicks are sintered to a thermally conducting pedestal above a pool of deionized water and heated from below. The apparent thermal resistance across the wick (from the pedestal/wick interface to the vapor space) under the evaporative operating conditions encountered in heat pipes is measured using thermocouples. The apparent thermal resistance across the wick is measured to be as low as 0.01 degrees C/W, corresponding to an evaporative heat transfer coefficient of greater than 128,000 W/m(2) K.
引用
收藏
页码:143 / 154
页数:12
相关论文
共 10 条
  • [1] Experimental study of evaporative heat transfer in sintered copper bidispersed wick structures
    Cao, XL
    Cheng, P
    Zhao, TS
    [J]. JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2002, 16 (04) : 547 - 552
  • [2] Cengel Y.A., 2019, Thermodynamics: An Engineering Approach
  • [3] CHIEN LH, 2002, THERMOMECHANICAL PHE
  • [4] SOME EXPERIMENTS ON SCREEN WICK DRY-OUT LIMITS
    CHUN, KR
    [J]. JOURNAL OF HEAT TRANSFER, 1972, 94 (01): : 46 - &
  • [5] IVERSON BD, 2007, AIAA J THERMOPHYS HE, V21, P392
  • [6] Kline S., 1953, Mech. Eng., V75, P38
  • [7] LI C, 2005, ASME PUBLICATION
  • [8] LI C, 2005, P ASME SUMM HEAT TRA
  • [9] LIN YY, 2005, 2005 ASME INT MECH E
  • [10] LIN YY, 2005, 2005 ASME SUMM HEAT