Characteristics and reproducibility of anterior chamber angle assessment by anterior-segment optical coherence tomography

被引:52
|
作者
Kim, Dong Y. [1 ]
Sung, Kyung R. [1 ]
Kang, Sung Y. [1 ]
Cho, Jung W. [1 ]
Lee, Kyoung S. [1 ]
Park, Seong B. [1 ,2 ]
Kim, Soon T. [1 ]
Kook, Michael S. [1 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Ophthalmol, Seoul 138736, South Korea
[2] Univ CHA, Coll Med, Bundang CHA Med Ctr, Dept Ophthalmol, Sung Nam, South Korea
关键词
anterior chamber angle; anterior-segment OCT; narrow angle; reproducibility; ULTRASOUND BIOMICROSCOPY; EYE; GONIOSCOPY; CLOSURE; PREVALENCE; GLAUCOMA; OCT;
D O I
10.1111/j.1755-3768.2009.01714.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the basic characteristics and reproducibility of anterior chamber angle (ACA) measurements determined by anterior-segment optical coherence tomography (AS-OCT) in open-angle and primary angle closure suspect (PACS) patients. Methods: Thirty-nine open-angle and 18 PACS patients were imaged for ACA by AS-OCT. Subjects underwent imaging of the nasal, temporal and inferior ACA under conditions of constant light, and darkness. For analysis, we used three ACA parameters handled by the Visante OCT software: angle opening distance at 500 mu m (AOD(500)), trabecular-iris space area at 500 mu m (TISA(500)) and angle recess area at 500 mu m (ARA(500)). For determination of inter-session reproducibility, a single well-trained operator (D.Y.K.) scanned all patients at two different visits. For determination of inter-operator variability, a second operator (S. B. P.) acquired another set of images independently. Three sets of images were acquired at least 24 hour apart. Results: All parameters were significantly different when measured both in light and darkness, and in the nasal and temporal quadrants. There were no significant differences between the left and right eyes in the three ACA parameters in all quadrants. The temporal angle was wider than the nasal and inferior angles. All parameters of the nasal, temporal angles had excellent inter-session and inter-operator reproducibility [intra-class correlation coefficient (ICC) 0.796-0.981], but these values were slightly lower for inferior angle measurements (ICC 0.662-0.892) in both open-angle and PACS groups. Conclusion: AS-OCT provides quantitative and reproducible assessment of ACA. Reproducibility was lower in the inferior angle compared with the nasal and temporal angles, perhaps because of variable placement of the scleral spur.
引用
收藏
页码:435 / 441
页数:7
相关论文
共 50 条
  • [1] Anatomical Changes of the Anterior Chamber Angle With Anterior-Segment Optical Coherence Tomography
    Liu, Lance
    ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (12) : 1682 - 1686
  • [2] Reproducibility of Anterior Chamber Angle Measurements with Anterior Segment Optical Coherence Tomography
    Tan, Annelie N.
    Sauren, Loes D. C.
    de Brabander, John
    Berendschot, Tos T. J. M.
    Passos, Valeria Lima
    Webers, Carroll A. B.
    Nuijts, Rudy M. M. A.
    Beckers, Henny J. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (05) : 2095 - 2099
  • [3] Reproducibility of anterior chamber angle measurements obtained with anterior segment optical coherence tomography
    Radhakrishnan, Sunita
    See, Jovina
    Smith, Scott D.
    Nolan, Winifred P.
    Ce, Zheng
    Friedman, David S.
    Huang, David
    Li, Yan
    Aung, Tin
    Chew, Paul T. K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (08) : 3683 - 3688
  • [4] Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography
    Li, Haitao
    Leung, Christopher Kai Shun
    Cheung, Carol Yim Lui
    Wong, Lee
    Pang, Chi Pui
    Weinreb, Robert Neal
    Lam, Dennis Shun Chiu
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (11) : 1490 - 1492
  • [5] Reproducibility of Anterior Chamber Angle Measurements With Anterior Segment Coherence Tomography
    De Brabander, J.
    Tan, A. N.
    Berendschot, T. T. J. M.
    Sauren, L. D. C.
    Nekeman, D.
    Passos, V. Lima
    Webers, C. A. B.
    Beckers, H. J. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [6] Anterior Chamber Angle Assessment by Anterior-segment Optical Coherence Tomography After Phacoemulsification With or Without Goniosynechialysis in Patients With Primary Angle Closure Glaucoma
    Shao, Tingting
    Hong, Jiaxu
    Xu, Jianjiang
    Le, Qihua
    Wang, Jiajian
    Qian, Shaohong
    JOURNAL OF GLAUCOMA, 2015, 24 (09) : 647 - 655
  • [7] Assessment of the Anterior Chamber Angle in Patients with Nanophthalmos: An Anterior Segment Optical Coherence Tomography Study
    Kara, Necip
    Baz, Okkes
    Altinkaynak, Hasan
    Altan, Cigdem
    Demirok, Ahmet
    CURRENT EYE RESEARCH, 2013, 38 (05) : 563 - 568
  • [8] Evaluation of the Narrow Anterior Chamber Angle by Anterior Segment Optical Coherence Tomography
    Lan, Jie
    Sun, Dapeng
    Alabdulrasool, Khatoon
    Yusuf, Hassan Ebrahim
    Zhang, Lu
    OPHTHALMIC RESEARCH, 2017, 57 (02) : 87 - 91
  • [9] Reproducibility and agreement of four anterior segment-optical coherence tomography devices for anterior chamber angle measurements
    Xiaojing Pan
    Jyotsna Maram
    Muneeswar G. Nittala
    Brian A. Francis
    Vikas Chopra
    Srinivas R. Sadda
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2020, 258 : 1475 - 1481
  • [10] Reproducibility and agreement of four anterior segment-optical coherence tomography devices for anterior chamber angle measurements
    Pan, Xiaojing
    Maram, Jyotsna
    Nittala, Muneeswar G.
    Francis, Brian A.
    Chopra, Vikas
    Sadda, Srinivas R.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (07) : 1475 - 1481