Nonenhanced Arterial Spin Labeled Carotid MR Angiography Using Three-Dimensional Radial Balanced Steady-State Free Precession Imaging

被引:17
|
作者
Koktzoglou, Ioannis [1 ,2 ]
Meyer, Joel R. [1 ,2 ]
Ankenbrandt, William J. [1 ,2 ]
Giri, Shivraman [3 ]
Piccini, Davide [4 ,5 ,6 ]
Zenge, Michael O. [7 ]
Flanagan, Oisin [1 ,8 ]
Desai, Tina [2 ,9 ]
Gupta, NavYash [2 ,9 ]
Edelman, Robert R. [1 ,8 ]
机构
[1] NorthShore Univ HealthSyst, Dept Radiol, Evanston, IL 60201 USA
[2] Univ Chicago, Pritzker Sch Med, Chicago, IL 60637 USA
[3] Siemens Healthcare, Chicago, IL USA
[4] Siemens Healthcare IM BM PI, Adv Clin Imaging Technol, Lausanne, Switzerland
[5] Univ Hosp CHUV, Dept Radiol, Lausanne, Switzerland
[6] Univ Lausanne UNIL, Ctr Biomed Imaging CIBM, Lausanne, Switzerland
[7] Siemens AG, Healthcare Sect, MR Prod Innovat & Definit, Erlangen, Germany
[8] Northwestern Univ, Feinberg Sch Med, Chicago, IL 60611 USA
[9] NorthShore Univ HealthSyst, Dept Surg, Evanston, IL 60201 USA
关键词
carotid; angiography; arterial spin labeling; radial; nonenhanced; INVERSION-RECOVERY; CONTRAST; STENOSIS;
D O I
10.1002/jmri.24640
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo optimize and preliminarily evaluate a three-dimensional (3D) radial balanced steady-state free precession (bSSFP) arterial spin labeled (ASL) sequence for nonenhanced MR angiography (MRA) of the extracranial carotid arteries. Materials and MethodsThe carotid arteries of 13 healthy subjects and 2 patients were imaged on a 1.5 Tesla MRI system using an undersampled 3D radial bSSFP sequence providing a scan time of approximate to 4 min and 1 mm(3) isotropic resolution. A hybridized scheme that combined pseudocontinuous and pulsed ASL was used to maximize arterial coverage. The impact of a post label delay period, the sequence repetition time, and radiofrequency (RF) energy configuration of pseudocontinuous labeling on the display of the carotid arteries was assessed with contrast-to-noise ratio (CNR) measurements. Faster, higher undersampled 2 and 1 min scans were tested. ResultsUsing hybridized ASL MRA and a 3D radial bSSFP trajectory, arterial CNR was maximized with a post label delay of 0.2 s, repetition times 2.5 s (P < 0.05), and by eliminating RF energy during the pseudocontinuous control phase (P < 0.001). With higher levels of undersampling, the carotid arteries were displayed in 2 min. ConclusionNonenhanced MRA using hybridized ASL with a 3D radial bSSFP trajectory can display long lengths of the carotid arteries with 1 mm(3) isotropic resolution. J. Magn. Reson. Imaging 2015;41:1150-1156. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:1150 / 1156
页数:7
相关论文
共 50 条
  • [41] Dynamic and steady-state oxygen-dependent lung relaxometry using inversion recovery ultra-fast steady-state free precession imaging at 1.5 T
    Bauman, Grzegorz
    Pusterla, Orso
    Santini, Francesco
    Bieri, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (02) : 839 - 845
  • [42] Non-contrast coronary artery wall and plaque imaging using inversion-recovery prepared steady-state free precession
    Ishimoto, Takeshi
    Taniguchi, Yasuyo
    Miyati, Tosiaki
    Kawakami, Momoe
    Ishihara, Masaru
    BMC MEDICAL IMAGING, 2015, 15
  • [43] Parametric Dependence of Myocardial Blood Oxygen Level Dependent, Balanced Steady-State Free-Precession Imaging at 1.5 T: Theory and Experiments
    Zhou, Xiangzhi
    Tang, Richard
    Klein, Rachel
    Li, Debiao
    Dharmakumar, Rohan
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (02) : 484 - 493
  • [44] Coronary wall MR Imaging in patients with rapid heart rates: a feasibility study of black-blood steady-state free precession (SSFP)
    Lin, Kai
    Bi, Xiaoming
    Taimen, Kirsi
    Zuehlsdorff, Sven
    Lu, Biao
    Carr, James
    Li, Debiao
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (03) : 567 - 575
  • [45] Multidirectional depiction of internal carotid arterial stenosis:: Three-dimensional time-of-might MR angiography versus rotational and conventional digital subtraction angiography
    Elgersma, OEH
    Wüst, AFJ
    Buijs, PC
    van der Graaf, Y
    Eikelboom, BC
    Mali, WPTM
    RADIOLOGY, 2000, 216 (02) : 511 - 516
  • [46] Non-contrast coronary artery wall and plaque imaging using inversion-recovery prepared steady-state free precession
    Takeshi Ishimoto
    Yasuyo Taniguchi
    Tosiaki Miyati
    Momoe Kawakami
    Masaru Ishihara
    BMC Medical Imaging, 15
  • [47] Non-Contrast-Enhanced MR Portography With Balanced Steady-State Free-Precession Sequence and Time-Spatial Labeling Inversion Pulses: Comparison of Imaging With Flow-In and Flow-Out Methods
    Furuta, Akihiro
    Isoda, Hiroyoshi
    Yamashita, Rikiya
    Ohno, Tsuyoshi
    Kawahara, Seiya
    Shimizu, Hironori
    Fujimoto, Koji
    Kido, Aki
    Kusahara, Hiroshi
    Togashi, Kaori
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (03) : 583 - 587
  • [48] Three-dimensional echo-planar cine imaging of cerebral blood supply using arterial spin labeling
    Shrestha, Manoj
    Mildner, Toralf
    Schlumm, Torsten
    Robertson, Scott Haile
    Moeller, Harald
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2016, 29 (06) : 799 - 810
  • [49] Comparison of 3D-diffusion-prepared segmented steady-state free precession and 2D fast spin echo imaging of femoral artery atherosclerosis
    Hayashi, Katsumi
    Mani, Venkatesh
    Nemade, Ajay
    Silvera, Stephane
    Fayad, Zahi A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (03) : 309 - 321
  • [50] Three-dimensional MR digital subtraction angiography using parallel imaging and keyhole data sampling in cerebrovascular diseases: initial experience
    Kazuhiro Tsuchiya
    Chinatsu Aoki
    Akira Fujikawa
    Junichi Hachiya
    European Radiology, 2004, 14 : 1494 - 1497