Nonenhanced Arterial Spin Labeled Carotid MR Angiography Using Three-Dimensional Radial Balanced Steady-State Free Precession Imaging

被引:17
|
作者
Koktzoglou, Ioannis [1 ,2 ]
Meyer, Joel R. [1 ,2 ]
Ankenbrandt, William J. [1 ,2 ]
Giri, Shivraman [3 ]
Piccini, Davide [4 ,5 ,6 ]
Zenge, Michael O. [7 ]
Flanagan, Oisin [1 ,8 ]
Desai, Tina [2 ,9 ]
Gupta, NavYash [2 ,9 ]
Edelman, Robert R. [1 ,8 ]
机构
[1] NorthShore Univ HealthSyst, Dept Radiol, Evanston, IL 60201 USA
[2] Univ Chicago, Pritzker Sch Med, Chicago, IL 60637 USA
[3] Siemens Healthcare, Chicago, IL USA
[4] Siemens Healthcare IM BM PI, Adv Clin Imaging Technol, Lausanne, Switzerland
[5] Univ Hosp CHUV, Dept Radiol, Lausanne, Switzerland
[6] Univ Lausanne UNIL, Ctr Biomed Imaging CIBM, Lausanne, Switzerland
[7] Siemens AG, Healthcare Sect, MR Prod Innovat & Definit, Erlangen, Germany
[8] Northwestern Univ, Feinberg Sch Med, Chicago, IL 60611 USA
[9] NorthShore Univ HealthSyst, Dept Surg, Evanston, IL 60201 USA
关键词
carotid; angiography; arterial spin labeling; radial; nonenhanced; INVERSION-RECOVERY; CONTRAST; STENOSIS;
D O I
10.1002/jmri.24640
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo optimize and preliminarily evaluate a three-dimensional (3D) radial balanced steady-state free precession (bSSFP) arterial spin labeled (ASL) sequence for nonenhanced MR angiography (MRA) of the extracranial carotid arteries. Materials and MethodsThe carotid arteries of 13 healthy subjects and 2 patients were imaged on a 1.5 Tesla MRI system using an undersampled 3D radial bSSFP sequence providing a scan time of approximate to 4 min and 1 mm(3) isotropic resolution. A hybridized scheme that combined pseudocontinuous and pulsed ASL was used to maximize arterial coverage. The impact of a post label delay period, the sequence repetition time, and radiofrequency (RF) energy configuration of pseudocontinuous labeling on the display of the carotid arteries was assessed with contrast-to-noise ratio (CNR) measurements. Faster, higher undersampled 2 and 1 min scans were tested. ResultsUsing hybridized ASL MRA and a 3D radial bSSFP trajectory, arterial CNR was maximized with a post label delay of 0.2 s, repetition times 2.5 s (P < 0.05), and by eliminating RF energy during the pseudocontinuous control phase (P < 0.001). With higher levels of undersampling, the carotid arteries were displayed in 2 min. ConclusionNonenhanced MRA using hybridized ASL with a 3D radial bSSFP trajectory can display long lengths of the carotid arteries with 1 mm(3) isotropic resolution. J. Magn. Reson. Imaging 2015;41:1150-1156. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:1150 / 1156
页数:7
相关论文
共 50 条
  • [21] Utility of Balanced Steady-State Free Precession MR Venography in the Diagnosis of Lower Extremity Deep Venous Thrombosis
    Lindquist, Chris M.
    Karlicki, Fern
    Lawrence, Patrick
    Strzelczyk, Jacek
    Pawlyshyn, Neal
    Kirkpatrick, Iain D. C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05) : 1357 - 1364
  • [22] Fluoroscopic contrast-enhanced MR angiography with a magnetization-prepared steady-state free precession technique in peripheral arterial occlusive disease
    Huegli, RW
    Aschwanden, M
    Scheffler, K
    Bilecen, D
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (01) : 242 - 247
  • [23] MRI of coronary vessel walls using radial k-space sampling and steady-state free precession imaging
    Katoh, M
    Spuentrup, E
    Buecker, A
    Schaeffter, T
    Stuber, M
    Günther, RW
    Botnar, RM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (06) : S401 - S406
  • [24] Interleaved, undersampled radial multiple-acquisition steady-state free precession for improved left atrial cine imaging
    Robb, Jaime S.
    Hu, Chenxi
    Peters, Dana C.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (05) : 1721 - 1729
  • [25] Rapid anatomical imaging of the neonatal brain using T2-prepared 3D balanced steady-state free precession
    Park, Jinho
    Jang, MinJung
    Heier, Linda
    Limperopoulos, Catherine
    Zun, Zungho
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (04) : 1456 - +
  • [26] Revisiting the Potential of Alternating Repetition Time Balanced Steady-State Free Precession Imaging of the Abdomen at 3 T
    Gurney-Champion, Oliver J.
    Nederveen, Aart J.
    Klaassen, Remy
    Engelbrecht, Marc R.
    Bel, Arjan
    van Laarhoven, Hanneke W. M.
    Stoker, Jaap
    Goncalves, Sonia I.
    INVESTIGATIVE RADIOLOGY, 2016, 51 (09) : 560 - 568
  • [27] Fat-suppressed steady-state free precession imaging using phase detection
    Hargreaves, BA
    Vasanawala, SS
    Nayak, KS
    Hu, BS
    Nishimura, DG
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (01) : 210 - 213
  • [28] Three-dimensional time-of-flight MR angiography and MR imaging versus conventional angiography in carotid artery dissections
    Stringaris, K
    Liberopoulos, K
    Giaka, E
    Kokkinis, K
    Bastounis, E
    Klonaris, EC
    Balas, P
    INTERNATIONAL ANGIOLOGY, 1996, 15 (01) : 20 - 25
  • [29] Nonenhanced hybridized arterial spin labeled magnetic resonance angiography of the extracranial carotid arteries using a fast low angle shot readout at 3 Tesla
    Ioannis Koktzoglou
    Matthew T. Walker
    Joel R. Meyer
    Ian G. Murphy
    Robert R. Edelman
    Journal of Cardiovascular Magnetic Resonance, 18
  • [30] Liver Lesion Conspicuity During Real-Time MR-Guided Radiofrequency Applicator Placement Using Spoiled Gradient Echo and Balanced Steady-State Free Precession Imaging
    Rempp, Hansjoerg
    Loh, Henning
    Hoffmann, Ruediger
    Rothgang, Eva
    Pan, Li
    Claussen, Claus D.
    Clasen, Stephan
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (02) : 432 - 439